Mostrar el registro sencillo del ítem
dc.contributor.author | Shepherd, Tony | es_ES |
dc.contributor.author | Teräs, Mika | es_ES |
dc.contributor.author | Beichel, Reinhard R. | es_ES |
dc.contributor.author | Boellaard, Ronald | es_ES |
dc.contributor.author | Bruynooghe, Michel | es_ES |
dc.contributor.author | Dicken, Volker | es_ES |
dc.contributor.author | Gooding, Mark J. | es_ES |
dc.contributor.author | Julyan, Peter J. | es_ES |
dc.contributor.author | Lee, John A. | es_ES |
dc.contributor.author | Lefèvre, Sébastien | es_ES |
dc.contributor.author | Mix, Michael | es_ES |
dc.contributor.author | Naranjo Ornedo, Valeriana | es_ES |
dc.contributor.author | Wu, Xiaodong | es_ES |
dc.contributor.author | Zaidi, Habib | es_ES |
dc.contributor.author | Zeng,Ziming | es_ES |
dc.contributor.author | Minn, Heikki | es_ES |
dc.date.accessioned | 2015-10-21T06:13:21Z | |
dc.date.available | 2015-10-21T06:13:21Z | |
dc.date.issued | 2012-11 | |
dc.identifier.issn | 0278-0062 | |
dc.identifier.uri | http://hdl.handle.net/10251/56282 | |
dc.description.abstract | [EN] The impact of positron emission tomography (PET) on radiation therapy is held back by poor methods of defining functional volumes of interest. Many new software tools are being proposed for contouring target volumes but the different approaches are not adequately compared and their accuracy is poorly evaluated due to the ill-definition of ground truth. This paper compares the largest cohort to date of established, emerging and proposed PET contouring methods, in terms of accuracy and variability. We emphasize spatial accuracy and present a new metric that addresses the lack of unique ground truth. Thirty methods are used at 13 different institutions to contour functional volumes of interest in clinical PET/CT and a custom-built PET phantom representing typical problems in image guided radiotherapy. Contouring methods are grouped according to algorithmic type, level of interactivity and how they exploit structural information in hybrid images. Experiments reveal benefits of high levels of user interaction, as well as simultaneous visualization of CT images and PET gradients to guide interactive procedures. Method-wise evaluation identifies the danger of over-automation and the value of prior knowledge built into an algorithm. | es_ES |
dc.description.sponsorship | For retrospective patient data and manual ground truth delineation, the authors wish to thank S. Suilamo, K. Lehtio, M. Mokka, and H. Minn at the Department of Oncology and Radiotherapy, Turku University Hospital, Finland. This study was funded by the Finnish Cancer Organisations. | |
dc.language | Inglés | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | es_ES |
dc.relation.ispartof | IEEE Transactions on Medical Imaging | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Human computer interaction | es_ES |
dc.subject | Image segmentation | es_ES |
dc.subject | Oncology | es_ES |
dc.subject | Performance evaluation | es_ES |
dc.subject | Phantoms | es_ES |
dc.subject | Positron emission tomography (PET) | es_ES |
dc.subject.classification | TEORIA DE LA SEÑAL Y COMUNICACIONES | es_ES |
dc.title | Comparative Study With New Accuracy Metrics for Target Volume Contouring in PET Image Guided Radiation Therapy | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1109/TMI.2012.2202322 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions | es_ES |
dc.description.bibliographicCitation | Shepherd, T.; Teräs, M.; Beichel, RR.; Boellaard, R.; Bruynooghe, M.; Dicken, V.; Gooding, MJ.... (2012). Comparative Study With New Accuracy Metrics for Target Volume Contouring in PET Image Guided Radiation Therapy. IEEE Transactions on Medical Imaging. 31(12):2006-2024. doi:10.1109/TMI.2012.2202322 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | Http://dx.doi.org/10.1109/TMI.2012.2202322 | es_ES |
dc.description.upvformatpinicio | 2006 | es_ES |
dc.description.upvformatpfin | 2024 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 31 | es_ES |
dc.description.issue | 12 | es_ES |
dc.relation.senia | 234590 | es_ES |
dc.identifier.pmid | 22692898 | |
dc.identifier.pmcid | PMC5570440 |