dc.contributor.author | Roldán Porta, Carlos | es_ES |
dc.contributor.author | Escrivá Escrivá, Guillermo | es_ES |
dc.contributor.author | Cárcel Carrasco, Francisco Javier | es_ES |
dc.contributor.author | Roldán Blay, Carlos | es_ES |
dc.date.accessioned | 2015-10-28T10:51:00Z | |
dc.date.available | 2015-10-28T10:51:00Z | |
dc.date.issued | 2014-01 | |
dc.identifier.issn | 0378-7796 | |
dc.identifier.uri | http://hdl.handle.net/10251/56635 | |
dc.description.abstract | Residual current circuit breakers (RCCBs) are often used to provide protection against indirect contacts in a grounded electrical installation. However, there are situations where the use of RCCBs presents certain problems. In some installations, tripping may occur for no apparent reason. Furthermore, it is very laborious and difficult to find the cause of such nuisance tripping in RCCBs. This article presents a case studied by the authors in the La Fe Hospital in Valencia (Spain), where the nuisance tripping of RCCBs became a serious problem. The methodology followed to find the causes and the solutions adopted are described. | es_ES |
dc.description.sponsorship | This research work has been possible with the support of La Fe Hospital and the Universitat Politecnica de Valencia. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Electric Power Systems Research | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Residual current circuit breaker | es_ES |
dc.subject | Nuisance tripping | es_ES |
dc.subject | Power quality faults | es_ES |
dc.subject.classification | INGENIERIA ELECTRICA | es_ES |
dc.subject.classification | CONSTRUCCIONES ARQUITECTONICAS | es_ES |
dc.title | Nuisance tripping of residual current circuit breakers: A practical case | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.epsr.2013.07.020 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Construcciones Arquitectónicas - Departament de Construccions Arquitectòniques | es_ES |
dc.description.bibliographicCitation | Roldán Porta, C.; Escrivá Escrivá, G.; Cárcel Carrasco, FJ.; Roldán Blay, C. (2014). Nuisance tripping of residual current circuit breakers: A practical case. Electric Power Systems Research. 106(1):180-187. doi:10.1016/j.epsr.2013.07.020 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.epsr.2013.07.020 | es_ES |
dc.description.upvformatpinicio | 180 | es_ES |
dc.description.upvformatpfin | 187 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 106 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.senia | 247296 | |
dc.contributor.funder | Universitat Politècnica de València | es_ES |
dc.contributor.funder | Hospital Universitari i Politècnic La Fe | es_ES |