High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Buendıa Fuentes, F. es_ES
dc.contributor.author Arnau Vives, M.A. es_ES
dc.contributor.author Arnau Vives, Antonio es_ES
dc.contributor.author Jiménez Jiménez, Yolanda es_ES
dc.contributor.author Rueda-Soriano, J. es_ES
dc.contributor.author Zorio-Grima,E . es_ES
dc.contributor.author Osa-Saez, A. es_ES
dc.contributor.author Martınez-Dolz, L. V. es_ES
dc.contributor.author Almenar-Bonet, L. es_ES
dc.contributor.author Palencia-Perez, M.A.
dc.date.accessioned 2015-10-28T13:35:17Z
dc.date.available 2015-10-28T13:35:17Z
dc.date.issued 2012
dc.identifier.issn 2090-5580
dc.identifier.uri http://hdl.handle.net/10251/56649
dc.description.abstract Introduction. Artifactual variations in the ST segment may lead to confusion with acute coronary syndromes. Objective. To evaluate how the technical characteristics of the recording mode may distort the ST segment. Material and Method. We made a series of electrocardiograms using different filter configurations in 45 asymptomatic patients. A spectral analysis of the electrocardiograms was made by discrete Fourier transforms, and an accurate recomposition of the ECG signal was obtained from the addition of successive harmonics. Digital high-pass filters of 0.05 and 0.5 Hz were used, and the resulting shapes were compared with the originals. Results. In 42 patients (93%) clinically significant alterations in ST segment level were detected. These changes were only seen in “real time mode” with high-pass filter of 0.5 Hz. Conclusions. Interpretation of the ST segment in “real time mode” should only be carried out using high-pass filters of 0.05 Hz. es_ES
dc.language Inglés es_ES
dc.publisher Hindawi Publishing Corporation es_ES
dc.relation.ispartof ISRN Cardiology es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject High-Bandpass Filters es_ES
dc.subject Electrocardiography es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.5402/2012/706217
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation Buendıa Fuentes, F.; Arnau Vives, M.; Arnau Vives, A.; Jiménez Jiménez, Y.; Rueda-Soriano, J.; Zorio-Grima, E..; Osa-Saez, A.... (2012). High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment. ISRN Cardiology. 2012:706217-706227. doi:10.5402/2012/706217 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.5402/2012/706217 es_ES
dc.description.upvformatpinicio 706217 es_ES
dc.description.upvformatpfin 706227 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 2012 es_ES
dc.relation.senia 242694 es_ES
dc.identifier.eissn 2090-5599
dc.identifier.pmcid PMC3388307 en_EN


Este ítem aparece en la(s) siguiente(s) colección(ones)