dc.contributor.author | Almerich Chulia, Ana Isabel | es_ES |
dc.contributor.author | Fenollosa Forner, Ernesto Jesús | es_ES |
dc.contributor.author | Cabrera Fausto, Ivan | es_ES |
dc.date.accessioned | 2015-10-28T18:33:41Z | |
dc.date.available | 2015-10-28T18:33:41Z | |
dc.date.issued | 2015 | |
dc.identifier.issn | 1022-6680 | |
dc.identifier.uri | http://hdl.handle.net/10251/56670 | |
dc.description.abstract | In order to obtain GFRP reinforcement bars it is necessary to undertake tests regulated code which require important mechanical tools. This paper presents a method which allows for determining GFRP rebars tensile strength value from their flexural strength value which has been obtained with a simple, inexpensive and reliable test. This method results will be verified by applying it to values obtained in a series of bending tests and comparing these results with values obtained in tensile tests. Values concordance for small diameter GFRP rebars is very good. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Trans Tech Publications | es_ES |
dc.relation.ispartof | Advanced Materials Research | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | GFRP bar | es_ES |
dc.subject | Strength | es_ES |
dc.subject | Tension | es_ES |
dc.subject | Bending | es_ES |
dc.subject.classification | MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS | es_ES |
dc.title | GFRP Bar: Determining Tensile Strength with Bending Test | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.4028/www.scientific.net/AMR.1083.90 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures | es_ES |
dc.description.bibliographicCitation | Almerich Chulia, AI.; Fenollosa Forner, EJ.; Cabrera Fausto, I. (2015). GFRP Bar: Determining Tensile Strength with Bending Test. Advanced Materials Research. 1083:90-96. doi:10.4028/www.scientific.net/AMR.1083.90 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.4028/www.scientific.net/AMR.1083.90 | es_ES |
dc.description.upvformatpinicio | 90 | es_ES |
dc.description.upvformatpfin | 96 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 1083 | es_ES |
dc.relation.senia | 278154 | es_ES |
dc.identifier.eissn | 1662-8985 | |
dc.description.references | A.I. Almerich Chulia. Diseño, según Estados Limites, de Estructuras de Hormigon Armado Con Redondos de Fibra de Vidrio GFRP,. Thesis, Universidad Politecnica de Valencia, Valencia, Spain (2010). | es_ES |
dc.description.references | UNE 83306: 1985 Concrete tests. Indirect tension failure (Brazilian test). | es_ES |
dc.description.references | UNE-EN 14651: 2007+A1: 2008. Test method for concrete with metallic fibers. Tensile strength determining by means of bending test (Limit of Proportionality (LOP), residual strength). | es_ES |
dc.description.references | UNE-EN ISO 178 Plastics: Flexural properties determining. | es_ES |
dc.description.references | UNE-EN 13706-2: 2003. Reinforced plastics composites - Specifications for pultruded profiles - Part 2: Methods of test and general requirements. | es_ES |
dc.description.references | UNE 66040: 2003 Statistical interpretation of test results. Estimation of the mean. Confidence interval.. | es_ES |
dc.description.references | A.I. Almerich-Chulia et al., Innovative Design of GFRP Bars for Concrete Structures,. Advanced Materials Research, 457-458, 553 (2012). | es_ES |