dc.contributor.author | Llopis, R. | es_ES |
dc.contributor.author | Cabello, R. | es_ES |
dc.contributor.author | Sanchez, D. | es_ES |
dc.contributor.author | Torrella Alcaraz, Enrique | es_ES |
dc.contributor.author | Patino, J. | es_ES |
dc.contributor.author | Sanchez, J. G. | es_ES |
dc.date.accessioned | 2015-10-29T12:26:03Z | |
dc.date.available | 2015-10-29T12:26:03Z | |
dc.date.issued | 2011-05 | |
dc.identifier.issn | 1359-4311 | |
dc.identifier.uri | http://hdl.handle.net/10251/56728 | |
dc.description.abstract | The Regulation CE-1005/2009 has banned the use of virgin HCFC-22 in Europe from the 31st December 2009, because it contains chlorine, although its use is allowed up to the 31st December 2014 if it is recycled. Now, manufacturers are developing different free-chlorine drop-in solutions to replace the HCFC-22 in the existing equipment by non-ozone depleting substances in order to exhaust its remaining life. This work focuses on the experimental evaluation of two HCFC-22 drop-in solutions for low temperature applications, the HFC-422A and the HFC-417B, in a double-stage vapour compression plant driven by a compound compressor in an evaporating temperature range between -31 and -17 degrees C and in a condensing temperature range between 30 and 48 degrees C. The experimental results show that there is a reduction in cooling capacity and in COP with regard to the HCFC-22 operation, which is analysed and discussed in the paper. | es_ES |
dc.description.sponsorship | The authors would like to thank Fundacion Caixa Castello-Bancaixa (P1.1B2008-12) and to Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) for their economic support given to the present study. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Applied Thermal Engineering | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Drop-in | es_ES |
dc.subject | R22 | es_ES |
dc.subject | Two-stage system | es_ES |
dc.subject | Compound compressor | es_ES |
dc.subject | R422A | es_ES |
dc.subject | R417B | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.title | Experimental evaluation of HCFC-22 replacement by the drop-in fluids HFC-422A and HFC-417B for low temperature refrigeration applications | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.applthermaleng.2011.01.003 | |
dc.relation.projectID | info:eu-repo/grantAgreement/UJI//P1·1B2008-12/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//CTM2008-06468-C02-02/ES/INSTALACIONES FRIGORIFICAS MEDIOAMBIENTALMENTE SOSTENIBLES. ESTUDIO DE ASPECTOS ENERGETICOS RELACIONADOS CON LA APLICACION DEL REFRIGERANTE NATURAL CO2./ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada | es_ES |
dc.description.bibliographicCitation | Llopis, R.; Cabello, R.; Sanchez, D.; Torrella Alcaraz, E.; Patino, J.; Sanchez, JG. (2011). Experimental evaluation of HCFC-22 replacement by the drop-in fluids HFC-422A and HFC-417B for low temperature refrigeration applications. Applied Thermal Engineering. 31(6-7):1323-1331. https://doi.org/10.1016/j.applthermaleng.2011.01.003 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.applthermaleng.2011.01.003 | es_ES |
dc.description.upvformatpinicio | 1323 | es_ES |
dc.description.upvformatpfin | 1331 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 31 | es_ES |
dc.description.issue | 6-7 | es_ES |
dc.relation.senia | 210691 | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Universitat Jaume I | es_ES |
dc.contributor.funder | Fundació Caixa Castelló - Bancaixa |