- -

Residual biomass calculation from individual tree architecture using terrestrial laser scanner and ground-level measurements

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Residual biomass calculation from individual tree architecture using terrestrial laser scanner and ground-level measurements

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Fernández-Sarría, Alfonso es_ES
dc.contributor.author Velázquez Martí, Borja es_ES
dc.contributor.author Sajdak, Magdalena es_ES
dc.contributor.author Martinez, Laura es_ES
dc.contributor.author Estornell Cremades, Javier es_ES
dc.date.accessioned 2015-11-26T15:48:03Z
dc.date.available 2015-11-26T15:48:03Z
dc.date.issued 2013-04
dc.identifier.issn 0168-1699
dc.identifier.uri http://hdl.handle.net/10251/58195
dc.description.abstract Large quantity of residual biomass with possible energy and industrial end can be obtained from management operations of urban forests. The profitability of exploiting this resource is conditioned by the amount of existing biomass within urban community ecosystems. Prior research pointed out that residual biomass from Platanus hispanica and other tree species can be calculated from dendrometric parameters. In this study, two approaches have been analyzed: First, applicability of TLS was tested for residual biomass calculation from crown volume. In addition, traditional models for residual biomass prediction were developed from dendrometric parameters (tree height, crown diameter, and diameter at breast height). Next, a comparison between parameters obtained with both methodologies (standard methodologies vs TLS) was carried out. The results indicate a strong relationship (R2 = 0.906) between crown diameters and between total tree heights (R2 = 0.868). The crown volumes extracted from the TLS point cloud were calculated by 4 different methods: convex hull; convex hull by slices of 5 cm height in the XY plane; triangulation by XY flat sections, and voxel modeling. The highest accuracy was found when the voxel method was used for pruned biomass prediction (R2 = 0.731). The results revealed the potential of TLS data to determine dendrometric parameters and biomass yielded from pruning quitar of urban forests es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Computers and Electronics in Agriculture es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Urban forest es_ES
dc.subject Residual biomass es_ES
dc.subject Allometric relationships es_ES
dc.subject Volume equations es_ES
dc.subject TLS es_ES
dc.subject Crown modeling es_ES
dc.subject.classification INGENIERIA CARTOGRAFICA, GEODESIA Y FOTOGRAMETRIA es_ES
dc.subject.classification INGENIERIA AGROFORESTAL es_ES
dc.title Residual biomass calculation from individual tree architecture using terrestrial laser scanner and ground-level measurements es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.compag.2013.01.012
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Cartográfica Geodesia y Fotogrametría - Departament d'Enginyeria Cartogràfica, Geodèsia i Fotogrametria es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Rural y Agroalimentaria - Departament d'Enginyeria Rural i Agroalimentària es_ES
dc.description.bibliographicCitation Fernández-Sarría, A.; Velázquez Martí, B.; Sajdak, M.; Martinez, L.; Estornell Cremades, J. (2013). Residual biomass calculation from individual tree architecture using terrestrial laser scanner and ground-level measurements. Computers and Electronics in Agriculture. 93:90-97. doi:10.1016/j.compag.2013.01.012 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.compag.2013.01.012 es_ES
dc.description.upvformatpinicio 90 es_ES
dc.description.upvformatpfin 97 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 93 es_ES
dc.relation.senia 237926 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem