dc.contributor.author |
Mota Babiloni, Adrián
|
es_ES |
dc.contributor.author |
Navarro Esbri, Joaquin
|
es_ES |
dc.contributor.author |
Barragán Cervera, Ángel
|
es_ES |
dc.contributor.author |
Moles Ribera, Francisco
|
es_ES |
dc.contributor.author |
Peris Pérez, Bernardo
|
es_ES |
dc.date.accessioned |
2015-12-15T08:29:11Z |
|
dc.date.available |
2015-12-15T08:29:11Z |
|
dc.date.issued |
2015-03 |
|
dc.identifier.issn |
0140-7007 |
|
dc.identifier.uri |
http://hdl.handle.net/10251/58807 |
|
dc.description.abstract |
[EN] This work presents an experimental analysis of a non-flammable R1234ze(E)/R134a mixture (R450A) as R134a drop-in replacement. While R134a has a high GWP value (1430), the R450A GWP is only 547. The experimental tests are carried out in a vapour compression plant equipped with a variable-speed compressor. The replacement suitability has been studied combining different operating conditions: evaporation temperature, condensation temperature and the use of an internal heat exchanger (IHX). The drop-in cooling capacity of R450A compared with R134a is 6% lower as average. R450A COP is even higher to those resulting with R134a (approximately 1%). The discharge temperature of R450A is lower than that of R134a, 2K as average. The IHX has a similar positive influence on the energy performance of both fluids. In conclusion, R450A can be considered as a good candidate to replace R134a. |
es_ES |
dc.description.sponsorship |
The authors thankfully acknowledge "Ministerio de Educacion, Cultura y Deporte" for supporting this work through "Becas y Contratos de Formacion de Profesorado Universitario del Programa Nacional de Formacion de Recursos Humanos de Investigacion del ejercicio 2012". |
|
dc.language |
Inglés |
es_ES |
dc.publisher |
Elsevier |
es_ES |
dc.relation.ispartof |
International Journal of Refrigeration |
es_ES |
dc.rights |
Reserva de todos los derechos |
es_ES |
dc.subject |
Refrigeration |
es_ES |
dc.subject |
R450A |
es_ES |
dc.subject |
R134a |
es_ES |
dc.subject |
Mixture |
es_ES |
dc.subject |
Energy efficiency |
es_ES |
dc.subject |
Drop-in |
es_ES |
dc.title |
Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement |
es_ES |
dc.type |
Artículo |
es_ES |
dc.identifier.doi |
10.1016/j.ijrefrig.2014.12.010 |
|
dc.rights.accessRights |
Abierto |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Instituto de Seguridad Industrial, Radiofísica y Medioambiental - Institut de Seguretat Industrial, Radiofísica i Mediambiental |
es_ES |
dc.description.bibliographicCitation |
Mota Babiloni, A.; Navarro Esbri, J.; Barragán Cervera, Á.; Moles Ribera, F.; Peris Pérez, B. (2015). Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement. International Journal of Refrigeration. 51:52-58. doi:10.1016/j.ijrefrig.2014.12.010 |
es_ES |
dc.description.accrualMethod |
S |
es_ES |
dc.relation.publisherversion |
http://dx.doi.org/10.1016/j.ijrefrig.2014.12.010 |
es_ES |
dc.description.upvformatpinicio |
52 |
es_ES |
dc.description.upvformatpfin |
58 |
es_ES |
dc.type.version |
info:eu-repo/semantics/publishedVersion |
es_ES |
dc.description.volume |
51 |
es_ES |
dc.relation.senia |
279955 |
es_ES |