Mostrar el registro sencillo del ítem
dc.contributor.author | Pollán, Marina | es_ES |
dc.contributor.author | Llobet Azpitarte, Rafael | es_ES |
dc.contributor.author | Miranda García, Josefa | es_ES |
dc.contributor.author | Antón Guirao, Joaquín | es_ES |
dc.contributor.author | Casals el Busto, María | es_ES |
dc.contributor.author | Martinez Gomez, Inmaculada | es_ES |
dc.contributor.author | Palop Jonquères, Carmen | es_ES |
dc.contributor.author | Ruiz Perales, Francisco | es_ES |
dc.contributor.author | Sanchez Contador, Carmen | es_ES |
dc.contributor.author | Vidal, Carmen | es_ES |
dc.contributor.author | Perez Gómez, Beatriz | es_ES |
dc.contributor.author | Salas Trejo, Dolores | es_ES |
dc.date.accessioned | 2015-12-21T10:45:29Z | |
dc.date.available | 2015-12-21T10:45:29Z | |
dc.date.issued | 2013 | |
dc.identifier.issn | 2193-1801 | |
dc.identifier.uri | http://hdl.handle.net/10251/59083 | |
dc.description.abstract | We developed a semi-automated tool to assess mammographic density (MD), a phenotype risk marker for breast cancer (BC), in full-field digital images and evaluated its performance testing its reproducibility, comparing our MD estimates with those obtained by visual inspection and using Cumulus, verifying their association with factors that influence MD, and studying the association between MD measures and subsequent BC risk. Three radiologists assessed MD using DM-Scan, the new tool, on 655 processed images (craniocaudal view) obtained in two screening centers. Reproducibility was explored computing pair-wise concordance correlation coefficients (CCC). The agreement between DM-Scan estimates and visual assessment (semi- uantitative scale, 6 categories) was quantified computing weighted kappa statistics (quadratic weights). DM-Scan and Cumulus readings were compared using CCC. Variation of DM-Scan measures by age, body mass index (BMI) and other MD modifiers was tested in regression mixed models with mammographic device as a random-effect term. The association between DM-Scan measures and subsequent BC was estimated in a case control study. All BC cases in screening attendants (2007 2010) at a center with full-field digital mammography were matched by age and screening year with healthy controls (127 pairs). DM-Scan was used to blindly assess MD in available mammograms (112 cases/119 controls). Unconditional logistic models were fitted, including age, menopausal status and BMI as confounders. DM-Scan estimates were very reliable (pairwise CCC: 0.921, 0.928 and 0.916). They showed a reasonable agreement with visual MD assessment (weighted kappa ranging 0.79-0.81). DM-Scan and Cumulus measures were highly concordant (CCC ranging 0.80-0.84), but ours tended to be higher (4%-5% on average). As expected, DM-Scan estimates varied with age, BMI, parity and family history of BC. Finally, DM-Scan measures were significantly associated with BC (p-trend=0.005). Taking MD<7% as reference, OR per categories of MD were: OR7%-17%=1.32 (95% CI=0.59-2.99), OR17%-28%=2.28 (95% CI=1.03-5.04) and OR>=29%=3.10 (95% CI=1.35-7.14). Our results confirm that DM-Scan is a reliable tool to assess MD in full-field digital mammograms. | es_ES |
dc.description.sponsorship | This work was supported by research grants from Spain's Health Research Fund (Fondo de INvestigacion Santiaria) (PI060386 & PI09/1230); Gent per Gent Fund (EDEMAC Project) and the Spanish Federation of Breast Cancer Patients (Federacion Espanola de Cancer de Mama) (FECMA 485 EPY 1170-10). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | SpringerOpen | es_ES |
dc.relation.ispartof | SpringerPlus | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Mammographic density | es_ES |
dc.subject | Breast density | es_ES |
dc.subject | Density assessment | es_ES |
dc.subject | Computer-assisted tool | es_ES |
dc.subject | Reliability | es_ES |
dc.subject.classification | LENGUAJES Y SISTEMAS INFORMATICOS | es_ES |
dc.title | Validation of DM-Scan, a computer-assisted tool to assess mammographic density in full-field digital mammograms | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1186/2193-1801-2-242 | |
dc.relation.projectID | info:eu-repo/grantAgreement/ISCIII//PI09%2F1230/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/ISCIII//PI06%2F0386/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/FECMA//485 EPY 1170–10/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Sistemas Informáticos y Computación - Departament de Sistemes Informàtics i Computació | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Área de Instituto de Ciencias de la Educación - Àrea de l'Institut de Ciències de l'Educació | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto Tecnológico de Informática - Institut Universitari Mixt Tecnològic d'Informàtica | es_ES |
dc.description.bibliographicCitation | Pollán, M.; Llobet Azpitarte, R.; Miranda García, J.; Antón Guirao, J.; Casals El Busto, M.; Martinez Gomez, I.; Palop Jonquères, C.... (2013). Validation of DM-Scan, a computer-assisted tool to assess mammographic density in full-field digital mammograms. SpringerPlus. 2(242):1-13. https://doi.org/10.1186/2193-1801-2-242 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1186/2193-1801-2-242 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 13 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 2 | es_ES |
dc.description.issue | 242 | es_ES |
dc.relation.senia | 252424 | es_ES |
dc.identifier.eissn | 2193-1801 | |
dc.identifier.pmid | 23865000 | en_EN |
dc.identifier.pmcid | PMC3693435 | en_EN |
dc.contributor.funder | Instituto de Salud Carlos III; Fondo de Investigaciones Sanitarias | es_ES |
dc.contributor.funder | Federación Española de Cáncer de Mama | es_ES |
dc.contributor.funder | Fundación Gent per Gent | es_ES |
dc.description.references | Ascunce N, Salas D, Zubizarreta R, Almazan R, Ibanez J, Ederra M: Cancer screening in Spain. Ann Oncol 2010, 21(Suppl 3):iii43-iii51. | es_ES |
dc.description.references | Assi V, Warwick J, Cuzick J, Duffy SW: Clinical and epidemiological issues in mammographic density. Nat Rev Clin Oncol 2012, 9: 33-40. | es_ES |
dc.description.references | Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310. | es_ES |
dc.description.references | Boyd NF, Martin LJ, Yaffe MJ, Minkin S: Mammographic density and breast cancer risk: current understanding and future prospects. Breast Cancer Res 2011, 13: 223. 10.1186/bcr2942 | es_ES |
dc.description.references | Byng JW, Yaffe MJ, Jong RA, Shumak RS, Lockwood GA, Tritchler DL, Boyd NF: Analysis of mammographic density and breast cancer risk from digitized mammograms. Radiographics 1998, 18: 1587-1598. | es_ES |
dc.description.references | Cabanes A, Pastor-Barriuso R, Garcia-Lopez M, Pedraz-Pingarron C, Sanchez-Contador C, Vazquez Carrete JA, Moreno MP, Vidal C, Salas D, Miranda-Garcia J, et al.: Alcohol, tobacco, and mammographic density: a population-based study. Breast Cancer Res Treat 2011, 129: 135-147. 10.1007/s10549-011-1414-5 | es_ES |
dc.description.references | Cuzick J, Warwick J, Pinney E, Duffy SW, Cawthorn S, Howell A, Forbes JF, Warren RM: Tamoxifen-induced reduction in mammographic density and breast cancer risk reduction: a nested case–control study. J Natl Cancer Inst 2011, 103: 744-752. 10.1093/jnci/djr079 | es_ES |
dc.description.references | Evans DG, Warwick J, Astley SM, Stavrinos P, Sahin S, Ingham S, McBurney H, Eckersley B, Harvie M, Wilson M, et al.: Assessing individual breast cancer risk within the U.K. National Health Service Breast Screening Program: a new paradigm for cancer prevention. Cancer Prev Res (Phila) 2012, 5: 943-951. 10.1158/1940-6207.CAPR-11-0458 | es_ES |
dc.description.references | Garrido-Estepa M, Ruiz-Perales F, Miranda J, Ascunce N, Gonzalez-Roman I, Sanchez-Contador C, Santamarina C, Moreo P, Vidal C, Peris M, et al.: Evaluation of mammographic density patterns: reproducibility and concordance among scales. BMC Cancer 2010, 10: 485. | es_ES |
dc.description.references | Harvey JA: Quantitative assessment of percent breast density: analog versus digital acquisition. Technol Cancer Res Treat 2004, 3: 611-616. | es_ES |
dc.description.references | Highnam RP, Brady JM, Shepstone BJ: Estimation of compressed breast thickness during mammography. Br J Radiol 1998, 71: 646-653. | es_ES |
dc.description.references | Keller BM, Nathan DL, Gavenonis SC, Chen J, Conant EF, Kontos D: Reader variability in breast density estimation from full-field digital mammograms: the effect of image postprocessing on relative and absolute measures. Acad Radiol 2013. Epub ahead of print | es_ES |
dc.description.references | Li J, Szekely L, Eriksson L, Heddson B, Sundbom A, Czene K, Hall P, Humphreys K: High-throughput mammographic-density measurement: a tool for risk prediction of breast cancer. Breast Cancer Res 2012, 14: R114. 10.1186/bcr3238 | es_ES |
dc.description.references | Lin LI: A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989, 45: 255-268. 10.2307/2532051 | es_ES |
dc.description.references | Manduca A, Carston MJ, Heine JJ, Scott CG, Pankratz VS, Brandt KR, Sellers TA, Vachon CM, Cerhan JR: Texture features from mammographic images and risk of breast cancer. Cancer Epidemiol Biomarkers Prev 2009, 18: 837-845. 10.1158/1055-9965.EPI-08-0631 | es_ES |
dc.description.references | McCormack VA, dos Santos Silva I: Breast density and parenchymal patterns as markers of breast cancer risk: a meta-analysis. Cancer Epidemiol Biomarkers Prev 2006, 15: 1159-1169. 10.1158/1055-9965.EPI-06-0034 | es_ES |
dc.description.references | Nielsen M, Karemore G, Loog M, Raundahl J, Karssemeijer N, Otten JD, Karsdal MA, Vachon CM, Christiansen C: A novel and automatic mammographic texture resemblance marker is an independent risk factor for breast cancer. Cancer Epidemiol 2011, 35: 381-387. 10.1016/j.canep.2010.10.011 | es_ES |
dc.description.references | Olson JE, Sellers TA, Scott CG, Schueler BA, Brandt KR, Serie DJ, Jensen MR, Wu FF, Morton MJ, Heine JJ, et al.: The influence of mammogram acquisition on the mammographic density and breast cancer association in the mayo mammography health study cohort. Breast Cancer Res 2012, 14: R147. 10.1186/bcr3357 | es_ES |
dc.description.references | Perez-Gomez B, Ruiz F, Martinez I, Casals M, Miranda J, Sanchez-Contador C, Vidal C, Llobet R, Pollan M, Salas D: Women's features and inter-/intra-rater agreement on mammographic density assessment in full-field digital mammograms (DDM-SPAIN). Breast Cancer Res Treat 2012, 132: 287-295. 10.1007/s10549-011-1833-3 | es_ES |
dc.description.references | Pollan M, Lope V, Miranda-Garcia J, Garcia M, Casanova F, Sanchez-Contador C, Santamarina C, Moreo P, Vidal C, Peris M, et al.: Adult weight gain, fat distribution and mammographic density in Spanish pre- and post-menopausal women (DDM-Spain). Breast Cancer Res Treat 2012, 134: 823-838. 10.1007/s10549-012-2108-3 | es_ES |
dc.description.references | Sala M, Salas D, Belvis F, Sanchez M, Ferrer J, Ibanez J, Roman R, Ferrer F, Vega A, Laso MS, et al.: Reduction in false-positive results after introduction of digital mammography: analysis from four population-based breast cancer screening programs in Spain. Radiology 2011, 258: 388-395. 10.1148/radiol.10100874 | es_ES |
dc.description.references | Schousboe JT, Kerlikowske K, Loh A, Cummings SR: Personalizing mammography by breast density and other risk factors for breast cancer: analysis of health benefits and cost-effectiveness. Ann Intern Med 2011, 155: 10-20. 10.7326/0003-4819-155-1-201107050-00003 | es_ES |
dc.description.references | Stone J, Ding J, Warren RM, Duffy SW, Hopper JL: Using mammographic density to predict breast cancer risk: dense area or percentage dense area. Breast Cancer Res 2010, 12: R97. 10.1186/bcr2778 | es_ES |
dc.description.references | Vachon CM, Brandt KR, Ghosh K, Scott CG, Maloney SD, Carston MJ, Pankratz VS, Sellers TA: Mammographic breast density as a general marker of breast cancer risk. Cancer Epidemiol Biomarkers Prev 2007, 16: 43-49. 10.1158/1055-9965.EPI-06-0738 | es_ES |
dc.description.references | Vachon C, Fowler EE, Tiffenberg G, Scott C, Pankratz VS, Sellers TA, Heine JJ: Comparison of percent density from raw and processed full field digital mammography data. Breast Cancer Res 2013, 15: R1. 10.1186/bcr3372 | es_ES |
dc.description.references | Yaffe MJ: Mammographic density. Measurement of mammographic density. Breast Cancer Res 2008, 10: 209. 10.1186/bcr2102 | es_ES |
dc.description.references | Yaghjyan L, Colditz GA, Collins LC, Schnitt SJ, Rosner B, Vachon C, Tamimi RM: Mammographic breast density and subsequent risk of breast cancer in postmenopausal women according to tumor characteristics. J Natl Cancer Inst 2011, 103: 1179-1189. 10.1093/jnci/djr225 | es_ES |