García Diego, FJ.; Sanchez-Quinche, A.; Merello Giménez, P.; Beltrán Medina, P.; Peris Ribera, CJ. (2013). Array of Hall Effect Sensors for Linear Positioning of a Magnet Independently of Its Strength Variation. A Case Study: Monitoring Milk Yield during Milking in Goats. Sensors. 13(6):8000-8012. doi:10.3390/s130608000
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/59978
Title:
|
Array of Hall Effect Sensors for Linear Positioning of a Magnet Independently of Its Strength Variation. A Case Study: Monitoring Milk Yield during Milking in Goats
|
Author:
|
García Diego, Fernando Juan
Sanchez-Quinche, Angel
Merello Giménez, Paloma
Beltrán Medina, Pedro
Peris Ribera, Cristófol Josep
|
UPV Unit:
|
Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada
Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal
|
Issued date:
|
|
Abstract:
|
In this study we propose an electronic system for linear positioning of a magnet independent of its modulus, which could vary because of aging, different fabrication process, etc. The system comprises a linear array of 24 ...[+]
In this study we propose an electronic system for linear positioning of a magnet independent of its modulus, which could vary because of aging, different fabrication process, etc. The system comprises a linear array of 24 Hall Effect sensors of proportional response. The data from all sensors are subject to a pretreatment (normalization) by row (position) making them independent on the temporary variation of its magnetic field strength. We analyze the particular case of the individual flow in milking of goats. The multiple regression analysis allowed us to calibrate the electronic system with a percentage of explanation R-2 = 99.96%. In our case, the uncertainty in the linear position of the magnet is 0.51 mm that represents 0.019 L of goat milk. The test in farm compared the results obtained by direct reading of the volume with those obtained by the proposed electronic calibrated system, achieving a percentage of explanation of 99.05%.
[-]
|
Subjects:
|
Hall effect sensors
,
milk yield
,
multiple regression
,
linear magnet position
|
Copyrigths:
|
Reconocimiento (by)
|
Source:
|
Sensors. (issn:
1424-8220
)
|
DOI:
|
10.3390/s130608000
|
Publisher:
|
MDPI
|
Publisher version:
|
http://dx.doi.org/10.3390/s130608000
|
Project ID:
|
Spanish Government (Ministerio de Ciencia e Innovacion) HAR2010-21944-C02-01 HAR2010-21944-C02-02
SENESCYT (Secretaria Nacional de Educacion Superior, Ciencia, Tecnologia e Innovacion) from the Equator Republic
|
Thanks:
|
This work was partially supported by the Spanish Government (Ministerio de Ciencia e Innovacion) under projects HAR2010-21944-C02-01 and HAR2010-21944-C02-02. A. Sanchez-Quinche acknowledges the support received from ...[+]
This work was partially supported by the Spanish Government (Ministerio de Ciencia e Innovacion) under projects HAR2010-21944-C02-01 and HAR2010-21944-C02-02. A. Sanchez-Quinche acknowledges the support received from SENESCYT (Secretaria Nacional de Educacion Superior, Ciencia, Tecnologia e Innovacion) from the Equator Republic.
[-]
|
Type:
|