Mostrar el registro sencillo del ítem
dc.contributor.author | García Diego, Fernando Juan | es_ES |
dc.contributor.author | Fernández Navajas, Angel | es_ES |
dc.contributor.author | Beltrán Medina, Pedro | es_ES |
dc.contributor.author | Merello Giménez, Paloma | |
dc.date.accessioned | 2016-01-18T11:41:24Z | |
dc.date.available | 2016-01-18T11:41:24Z | |
dc.date.issued | 2013-09 | |
dc.identifier.issn | 1424-8220 | |
dc.identifier.uri | http://hdl.handle.net/10251/59979 | |
dc.description.abstract | The mudejar church of Santa Maria (Ateca) is valuable for its architecture and the altarpiece contained inside. Ateca is a village with continental climate characterized by cold winters and hot summers. In this paper we are interested in analysing the effect of temperature and relative humidity (RH) changes produced by the heating system on the altarpiece. Therefore, a monitoring system of 15 temperature and 15 relative humidity sensors was installed with a recording frequency of a data point per minute. The main contribution of this paper is the quantitative study of the effect of the heating system on the thermo-hygrometric parameters using statistical techniques such as ANOVA, mean daily trajectories or bivariate plots, and the proposal of an innovative dynamic contour plot. As results, the heating system produces a substantial increase (decrease) of temperature (RH) causing an hourly variation of these physical parameters detrimental to the conservation of the altarpiece, especially in its higher areas. | es_ES |
dc.description.sponsorship | This work was partially supported by the Spanish Government (Ministerio de Ciencia e Innovacion) under projects HAR2010-21944-C02-01 and HAR2010-21944-C02-02. The authors thank the companies Albarium S.L., that made the restoration, and Artechnology S.L., which supplied the sensors and to Carmen Perez from Instituto Valenciano de Conservacion y Restauracion de Bienes Culturales (IVC+R). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation.ispartof | Sensors | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | preventive conservation | es_ES |
dc.subject | Spanish cultural heritage | es_ES |
dc.subject | temperature and humidity sensors | es_ES |
dc.subject | climate control system | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Study of the Effect of the Strategy of Heating on the Mudejar Church of Santa Maria in Ateca (Spain) for Preventive Conservation of the Altarpiece Surroundings | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/s130911407 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//HAR2010-21944-C02-01/ES/CARACTERIZACION MICROCLIMATICA DE OBRAS DE ARTE ENFOCADA A LA CONSERVACION PREVENTIVA DE LAS MISMAS/ | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//HAR2010-21944-C02-02/ES/MONITORIZACION Y ESTUDIO DE DEGRADACION EN OBRAS DE ARTE ENFOCADO A LA CONSERVACION PREVENTIVA DE LAS MISMAS./ | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.description.bibliographicCitation | García Diego, FJ.; Fernández Navajas, A.; Beltrán Medina, P.; Merello Giménez, P. (2013). Study of the Effect of the Strategy of Heating on the Mudejar Church of Santa Maria in Ateca (Spain) for Preventive Conservation of the Altarpiece Surroundings. Sensors. 13(9):11407-11423. https://doi.org/10.3390/s130911407 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.3390/s130911407 | es_ES |
dc.description.upvformatpinicio | 11407 | es_ES |
dc.description.upvformatpfin | 11423 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 13 | es_ES |
dc.description.issue | 9 | es_ES |
dc.relation.senia | 248517 | es_ES |
dc.identifier.pmid | 24064599 | en_EN |
dc.identifier.pmcid | PMC3821349 | en_EN |
dc.contributor.funder | Ministerio de Ciencia e Innovación |