Mostrar el registro sencillo del ítem
dc.contributor.author | Remón Martín, Laura | es_ES |
dc.contributor.author | Arias, Augusto | es_ES |
dc.contributor.author | Calatayud Calatayud, Arnau | es_ES |
dc.contributor.author | Furlan, Walter Daniel | es_ES |
dc.contributor.author | Monsoriu Serra, Juan Antonio | es_ES |
dc.date.accessioned | 2016-01-20T09:13:30Z | |
dc.date.available | 2016-01-20T09:13:30Z | |
dc.date.issued | 2012-12-20 | |
dc.identifier.issn | 1559-128X | |
dc.identifier.uri | http://hdl.handle.net/10251/60053 | |
dc.description.abstract | A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method. | es_ES |
dc.description.sponsorship | We acknowledge the financial support from Ministerio de Ciencia e Innovacion (grants FIS2011-23175 and TRA2009-0215), Generalitat Valenciana (grant PROMETEO2009-077), and Universitat Politecnica de Valencia (PAID-05-11), Spain. L. Remon acknowledges a fellowship of "Fundacion Cajamurcia," Spain. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Optical Society of America | es_ES |
dc.relation.ispartof | Applied optics | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Defocus transfer-function | es_ES |
dc.subject | Optical-performance | es_ES |
dc.subject | Image quality | es_ES |
dc.subject | In-vivo | es_ES |
dc.subject | Decentration | es_ES |
dc.subject | Tilt | es_ES |
dc.subject | Designs | es_ES |
dc.subject | Aberrations | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1364/AO.51.008594 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//FIS2011-23175/ES/DISEÑO Y REALIZACION DE ESTRUCTURAS DIFRACTIVAS APERIODICAS: NUEVAS LENTES OFTALMICAS Y OTRAS APLICACIONES/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//TRA2009_0215/ES/Lentes intraoculares multifocales. Fabricación y caracterización de prototipos basados en secuencias aperiódicas./ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEO%2F2009%2F077/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//PAID-05-11/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.description.bibliographicCitation | Remón Martín, L.; Arias, A.; Calatayud Calatayud, A.; Furlan, WD.; Monsoriu Serra, JA. (2012). Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator. Applied optics. 36(51):8594-8598. https://doi.org/10.1364/AO.51.008594 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1364/AO.51.008594 | es_ES |
dc.description.upvformatpinicio | 8594 | es_ES |
dc.description.upvformatpfin | 8598 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 36 | es_ES |
dc.description.issue | 51 | es_ES |
dc.relation.senia | 233736 | es_ES |
dc.identifier.eissn | 2155-3165 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Universitat Politècnica de València | es_ES |
dc.description.references | Portney, V. (1992). Optical testing and inspection methodology for modern intraocular lenses. Journal of Cataract & Refractive Surgery, 18(6), 607-613. doi:10.1016/s0886-3350(13)80453-1 | es_ES |
dc.description.references | Rawer, R., Stork, W., Spraul, C. W., & Lingenfelder, C. (2005). Imaging quality of intraocular lenses. Journal of Cataract & Refractive Surgery, 31(8), 1618-1631. doi:10.1016/j.jcrs.2005.01.033 | es_ES |
dc.description.references | Barbero, S., Marcos, S., & Jiménez-Alfaro, I. (2003). Optical aberrations of intraocular lenses measured in vivo and in vitro. Journal of the Optical Society of America A, 20(10), 1841. doi:10.1364/josaa.20.001841 | es_ES |
dc.description.references | Schwiegerling, J., & DeHoog, E. (2010). Problems testing diffractive intraocular lenses with Shack-Hartmann sensors. Applied Optics, 49(16), D62. doi:10.1364/ao.49.000d62 | es_ES |
dc.description.references | Schwiegerling, J. (2007). Analysis of the Optical Performance of Presbyopia Treatments With the Defocus Transfer Function. Journal of Refractive Surgery, 23(9), 965-971. doi:10.3928/1081-597x-20071101-19 | es_ES |
dc.description.references | ATCHISON, D. A. (1989). Optical Design of Intraocular Lenses. III. On-Axis Performance in the Presence of Lens Displacement. Optometry and Vision Science, 66(10), 671-681. doi:10.1097/00006324-198910000-00003 | es_ES |
dc.description.references | Taketani, F., Matuura, T., Yukawa, E., & Hara, Y. (2004). Influence of intraocular lens tilt and decentration on wavefront aberrations. Journal of Cataract & Refractive Surgery, 30(10), 2158-2162. doi:10.1016/j.jcrs.2004.02.072 | es_ES |
dc.description.references | Altmann, G. E., Nichamin, L. D., Lane, S. S., & Pepose, J. S. (2005). Optical performance of 3 intraocular lens designs in the presence of decentration. Journal of Cataract & Refractive Surgery, 31(3), 574-585. doi:10.1016/j.jcrs.2004.09.024 | es_ES |
dc.description.references | Phillips, P., Rosskothen, H. D., Pérez-Emmanuelli, J., & Koester, C. J. (1988). Measurement of intraocular lens decentration and tilt in vivo. Journal of Cataract & Refractive Surgery, 14(2), 129-135. doi:10.1016/s0886-3350(88)80086-5 | es_ES |
dc.description.references | De Castro, A., Rosales, P., & Marcos, S. (2007). Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Journal of Cataract & Refractive Surgery, 33(3), 418-429. doi:10.1016/j.jcrs.2006.10.054 | es_ES |
dc.description.references | Sasaki, K., Sakamoto, Y., Shibata, T., Nakaizumi, H., & Emori, Y. (1989). Measurement of postoperative intraocular lens tilting and decentration using Scheimpflug images. Journal of Cataract & Refractive Surgery, 15(4), 454-457. doi:10.1016/s0886-3350(89)80071-9 | es_ES |
dc.description.references | Eppig, T., Scholz, K., Löffler, A., Meßner, A., & Langenbucher, A. (2009). Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye. Journal of Cataract & Refractive Surgery, 35(6), 1091-1100. doi:10.1016/j.jcrs.2009.01.034 | es_ES |
dc.description.references | Calatayud, A., Rodrigo, J. A., Remón, L., Furlan, W. D., Cristóbal, G., & Monsoriu, J. A. (2012). Experimental generation and characterization of Devil’s vortex-lenses. Applied Physics B, 106(4), 915-919. doi:10.1007/s00340-012-4913-0 | es_ES |
dc.description.references | Simpson, M. J. (1992). Diffractive multifocal intraocular lens image quality. Applied Optics, 31(19), 3621. doi:10.1364/ao.31.003621 | es_ES |
dc.description.references | ATCHISON, D. A., YE, M., BRADLEY, A., COLLINS, M. J., ZHANG, X., RAHMAN, H. A., & THIBOS, L. N. (1992). Chromatic Aberration and Optical Power of a Diffractive Bifocal Contact Lens. Optometry and Vision Science, 69(10), 797-804. doi:10.1097/00006324-199210000-00009 | es_ES |
dc.description.references | Portney, V. (2011). Light distribution in diffractive multifocal optics and its optimization. Journal of Cataract & Refractive Surgery, 37(11), 2053-2059. doi:10.1016/j.jcrs.2011.04.038 | es_ES |
dc.description.references | Castignoles, F., Flury, M., & Lepine, T. (2010). Comparison of the efficiency, MTF and chromatic properties of four diffractive bifocal intraocular lens designs. Optics Express, 18(5), 5245. doi:10.1364/oe.18.005245 | es_ES |