Ultrasonic characterization of GRC with high percentage of fly ash substitution

Show full item record

Genovés Gómez, V.; Gosálbez Castillo, J.; Miralles Ricós, R.; Bonilla Salvador, MM.; Paya Bernabeu, JJ. (2015). Ultrasonic characterization of GRC with high percentage of fly ash substitution. Ultrasonics. 60:88-95. doi:10.1016/j.ultras.2015.02.016

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/60095

Files in this item

Item Metadata

Title: Ultrasonic characterization of GRC with high percentage of fly ash substitution
Author:
UPV Unit: Universitat Politècnica de València. Instituto de Ciencia y Tecnología del Hormigón - Institut de Ciència i Tecnologia del Formigó
Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions
Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil
Issued date:
Abstract:
New applications of non-destructive techniques (NDT) with ultrasonic tests (attenuation and velocity by means of ultrasonic frequency sweeps) have been developed for the characterization of fibre-reinforced cementitious ...[+]
Subjects: GRC , Fly ash , Attenuation , Pulse velocity , Frequency sweep
Copyrigths: Reserva de todos los derechos
Source:
Ultrasonics. (issn: 0041-624X ) (eissn: 1874-9968 )
DOI: 10.1016/j.ultras.2015.02.016
Publisher:
Elsevier
Publisher version: http://dx.doi.org/10.1016/j.ultras.2015.02.016
Thanks:
This work has been supported by the Government of Spain under Grant TEC2011-23403 01/01/2012