dc.description.abstract | [EN] A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l(-1)) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples h(-1) of Bromoxynil in a wide interval of concentrations, over the range 5 x 10(-3) - 1 mg l(-1); the detection limit was 5 x 10(-3) mg l(-1). The RSD (n = 24) at 0.25 mg l(-1) of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation. | es_ES |
dc.description.sponsorship | This research was supported by Ministerio de Educación y Ciencia (Spanish Government), Project BQU2002-04248-C02-01. | |
dc.language | Inglés | es_ES |
dc.publisher | Nihon Bunseki Kagakkai (Japan Society for Analytical Chemistry) | es_ES |
dc.relation.ispartof | Analytical Sciences | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Bromoxynil | es_ES |
dc.subject | Chemiluminescent measurements | es_ES |
dc.subject | Flow injection analysis | es_ES |
dc.subject | Hydrogen-Ion Concentration | es_ES |
dc.subject | Molecular structure | es_ES |
dc.subject | Nitriles | es_ES |
dc.subject | Photochemistry | es_ES |
dc.subject | Sensitivity and specificity | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection assembly | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.2116/analsci.22.29 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICYT//BQU2002-04248-C02-01/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres | es_ES |
dc.description.bibliographicCitation | Pawlicova, Z.; Albert-Garcia, JR.; Sahuquillo, I.; García Mateo, JV.; Catalá-Icardo, M.; Martínez Calatayud, J. (2006). Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection assembly. Analytical Sciences. 22(1):29-34. https://doi.org/10.2116/analsci.22.29 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://doi.org/10.2116/analsci.22.29 | es_ES |
dc.description.upvformatpinicio | 29 | es_ES |
dc.description.upvformatpfin | 34 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 22 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.senia | 27487 | es_ES |
dc.identifier.eissn | 1348-2246 | |
dc.identifier.pmid | 16429768 | |
dc.contributor.funder | Ministerio de Ciencia y Tecnología |