Mostrar el registro sencillo del ítem
dc.contributor.author | García Narbón, José Vicente | es_ES |
dc.contributor.author | Rocha, M.I. | es_ES |
dc.contributor.author | March Iborra, Mª Del Carmen | es_ES |
dc.contributor.author | García, P. | es_ES |
dc.contributor.author | Francis, Laurent A | es_ES |
dc.contributor.author | Montoya Baides, Ángel | es_ES |
dc.contributor.author | Arnau Vives, Antonio | es_ES |
dc.contributor.author | Jiménez Jiménez, Yolanda | es_ES |
dc.date.accessioned | 2016-03-02T12:47:16Z | |
dc.date.available | 2016-03-02T12:47:16Z | |
dc.date.issued | 2014 | |
dc.identifier.issn | 1877-7058 | |
dc.identifier.uri | http://hdl.handle.net/10251/61365 | |
dc.description.abstract | [EN] In this work we determined the Sensitivity (estimated as the I50 value) and Limit of Detection (LOD) for the immunodetection of carbaryl pesticide with two different types of acoustic wave sensors: High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCM) and Love Mode Surface Acoustic Wave (LM-SAW). Results were compared with others previously reported using different sensors and techniques, like traditional QCM, Surface Plasmon Resonance (SPR) and Enzyme-Linked ImmunoSorbent Assay (ELISA). We used the AWS-A10 research platform (AWSensors, Spain) to perform the experiments. We obtained I50 values of 0.31 μg/L and 0.66 μg/L, and LODs of 0.09 μg/L and 0.14 μg/L, for 120 MHz LM-SAW and 100 MHz HFF-QCM devices, respectively. Both the sensitivities and LODs of the immunosensors improved previously reported SPR and QCM results by one and two orders of magnitude, respectively, and reached those of ELISA. | es_ES |
dc.description.sponsorship | The authors acknowledge: the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (ERDF) for their financing support through the grant of the INNPACTO 2012 project (DETECTA IPT-2012-0154-300000) and J.V. García's Fellowship, ref. AP2007-03745 of the FPU (Formación de Profesorado Universitario) program; the Mexican Consejo Nacional de Ciencia y Tecnología (CONACyT) for M.I. Rocha-Gaso's PhD CONACyT Fellowship. | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Procedia Engineering | es_ES |
dc.rights | Reconocimiento - No comercial - Compartir igual (by-nc-sa) | es_ES |
dc.subject | Acoustic wave sensor | es_ES |
dc.subject | Biosensor | es_ES |
dc.subject | Immunosensor | es_ES |
dc.subject | Carbaryl | es_ES |
dc.subject | Pesticide | es_ES |
dc.subject | QCM | es_ES |
dc.subject | SAW | es_ES |
dc.subject | Love wave | es_ES |
dc.subject | High Fundamental Frequency | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Love Mode Surface Acoustic Wave and High Fundamental Frequency Quartz Crystal Microbalance immunosensors for the detection of carbaryl pesticide | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.proeng.2014.11.649 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//IPT-2012-0154-300000/ES/DEMOSTRADOR TECNOLÓGICO BASADO EN TRANSDUCTORES ACÚSTICOS PARA APLICACIONES DE PREVENCIÓN Y DIAGNÓSTICO EN SALUD (DETECTA)/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//AP2007-03745/ES/AP2007-03745/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano - Institut Interuniversitari d'Investigació en Bioenginyeria i Tecnologia Orientada a l'Ésser Humà | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | García Narbón, JV.; Rocha, M.; March Iborra, MDC.; García, P.; Francis, LA.; Montoya Baides, Á.; Arnau Vives, A.... (2014). Love Mode Surface Acoustic Wave and High Fundamental Frequency Quartz Crystal Microbalance immunosensors for the detection of carbaryl pesticide. Procedia Engineering. 87:759-762. https://doi.org/10.1016/j.proeng.2014.11.649 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.proeng.2014.11.649 | es_ES |
dc.description.upvformatpinicio | 759 | es_ES |
dc.description.upvformatpfin | 762 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 87 | es_ES |
dc.relation.senia | 279896 | es_ES |
dc.contributor.funder | Ministerio de Educación y Ciencia |