Fire design methods for slim-floor structures

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Fire design methods for slim-floor structures

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Romero, Manuel L. es_ES
dc.contributor.author Cajot,Louis-Guy es_ES
dc.contributor.author Conan, Yves es_ES
dc.contributor.author Braun, Matthias es_ES
dc.date.accessioned 2016-03-08T09:47:49Z
dc.date.issued 2015-05
dc.identifier.issn 1867-0539
dc.identifier.uri http://hdl.handle.net/10251/61541
dc.description.abstract Slim-floor beams are well-known, sustainable and economical solutions for residential, commercial and industrial buildings. However, despite their widespread use, Eurocode 4 contains no specific simplified calculation methods for the fire resistance of integrated and shallow floor beams. There is a clear need for an improved understanding of the performance of structures in fire plus clear and cost-effective design guidance. This paper presents a set of simplified rules for determining thermal fields in the lower flange, web, rebars and slab of slim or integrated floor beams. This calculation methodology is based on existing formulas taken from different parts of Eurocode 4 except for the temperature calculation in the lower flange, which is deduced from a parametrical study using the SAFIR software. es_ES
dc.language Inglés es_ES
dc.publisher Ernst und Sohn: OnlineOpen es_ES
dc.relation.ispartof Steel Construction es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Slim floors es_ES
dc.subject Fire resistance es_ES
dc.subject Simplified methods es_ES
dc.subject Composite steel-concrete structures es_ES
dc.subject Shallow floor beams es_ES
dc.subject Methods of analysis and design es_ES
dc.subject Composite construction es_ES
dc.subject.classification MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS es_ES
dc.title Fire design methods for slim-floor structures es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.1002/stco.201510012
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures es_ES
dc.description.bibliographicCitation Romero, ML.; Cajot, L.; Conan, Y.; Braun, M. (2015). Fire design methods for slim-floor structures. Steel Construction. 8(2):102-109. doi:10.1002/stco.201510012 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1002/stco.201510012 es_ES
dc.description.upvformatpinicio 102 es_ES
dc.description.upvformatpfin 109 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 8 es_ES
dc.description.issue 2 es_ES
dc.relation.senia 290047 es_ES
dc.identifier.eissn 1867-0539
dc.description.references CEN European Committee for Standardization: EN 1994-1-2, Eurocode 4: Design of composite steel and concrete structures - Part 1-2: General rules - Structural fire design. Brussels, 2005. es_ES
dc.description.references Cajot , L. G. Franssen , J. M. Debruyckere , R. Guides de construction Métallique. Sécurité Incendie. INFOSTEEL, 2012. es_ES
dc.description.references European Convention for Constructional Steelwork TC3: Model Code on Fire Engineering, 2001. es_ES
dc.description.references British Steel: BS 476: Part 21: Fire Resistance Tests Summary of Data Obtained During a Test on a Composite Slim Floor Beam, Swinden Technology Centre, Moorgate, Rotherham, 1996. es_ES
dc.description.references Both , C. Fellinger , J. H. H. Twilt , L. Shallow floor construction with deep composite deck: from fire tests to simple calculation rules. HERON, 1997, vol. 42(3): pp. 145-152. es_ES
dc.description.references Schleich , J. B. Cajot , L. G. Brasseur Test au feu sur un plancher type “Slim floor”. RPS report No. 24/95, EMPA/ETH, Zurich, 1994. es_ES
dc.description.references Lawson , R. M. Fire resistance of Slim Floor Beams. Draft final report, ECSC research project, 1997. es_ES
dc.description.references Schleich , J. B. Slim Floor Construction: Why? Composite construction - conventional and innovative, Intl. Conf., Innsbruck, Proc., 1997, pp. 53-64. es_ES
dc.description.references Mullett , D. L. Lawson , R. M. Slim Floor Construction using deep decking. The Steel Construction Institute, pub. P127, 1993. es_ES
dc.description.references Mullett , D. L. Slim Floor Design and Construction. The Steel Construction Institute, pub. P110, 1992. es_ES
dc.description.references Cajot , L. G. Gallois , L. Debruyckere , R. Franssen , J.-M. Simplified design method for slim floor beams exposed to fire. Nordic Steel Construction Conf., Oslo, 2012. es_ES
dc.description.references Borgogno , W. Fontana , M. Versuche zum Tragverhalten von Betonhohlplatten mit flexibler Auflagerung bei Raumtemperatur und Normbrandbedingungen (Experiments on the behavior of hollow core slabs with flexible bearing at room temperature and standard fire conditions). PhD thesis, Institute of Structural Engineering, ETH Zurich, 1996 (in German). es_ES
dc.description.references Peltonen , S. Fire tests of a slim-floor structure. 6th European Conf on Steel & Composite Structures (Eurosteel 2011), vol. B, pp. 1545-1550. es_ES
dc.description.references Newman , G. M. Fire resistance of slim floor beams. Journal of constructional steel research, 33.1-2 (1995), pp. 87-100. es_ES
dc.description.references Bailey , C. G. The behaviour of asymmetric slim floor steel beams in fire. Journal of Constructional Steel Research, 50 (1999), pp. 235-257. es_ES
dc.description.references Makelainen , P. Ma , Z. Fire resistance of composite slim floor beams. Journal of constructional steel research, 54.3 (2000), pp. 345-363. es_ES
dc.description.references Ma , Z. Mäkeläinen , P. Behaviour of composite slim floor structures in fire. Journal of Structural Engineering, ASCE, 126(7), 2000, pp. 830-837. es_ES
dc.description.references Ellobody , E. Nonlinear behaviour of unprotected composite slim floor steel beams exposed to different fire conditions. Thin-Walled Structures, 49 (2011), pp. 762-771. es_ES
dc.description.references Maraveas , C. Numerical analysis of delta composite beams in fire. 7th European Conf. on Steel & Composite Structures, 10-12 Sept, 2014, Naples, paper 27-150. es_ES
dc.description.references Zaharia , R. Duma , D. Vassart , O. Gernay , T. Franssen , J. M. Simplified method for temperature distributions in slim floor beams. Application of Structural Fire Design, 29 Apr 2011, Prague. es_ES
dc.description.references Zaharia , R. Franssen , J. M. Simple equations for the calculation of temperature within the cross-section of slim floor beams under ISO fire. Steel and Composite Structures, vol. 13, 2012, No. 2, pp. 171-185. es_ES
dc.description.references CEN European Committee for Standardization: EN 1993-1-2, Eurocode 4: Design of steel structures - Part 1-2: General rules - Structural fire design. Brussels, 2005. es_ES
dc.description.references Braun , M. Obiala , R. Odenbreit , C. Hechler , O. CoSFB - Design and Application of a New Generation of Slim-Floor Construction, 7th European Conf. on Steel & Composite Structures (Eurosteel), 2014, Naples. es_ES
dc.description.references Sha , W. Chan , T. M. Intumescent fire protection coating thickness for shallow floor beams. Advances in Building Technology, 2002, vol. 2, pp. 1321-1328. es_ES
dc.description.references Choi , S. Ali , F. Nadjai , A. Han , S. Choi , J. Structural performance of slim-beam floor system in fire. Journal of Structural Fire Engineering 2011, vol. 2(1), pp. 57-67. es_ES