Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Cirugeda Roldán, Eva María es_ES
dc.contributor.author Novak, Daniel es_ES
dc.contributor.author Kremen, Vaclav es_ES
dc.contributor.author Cuesta Frau, David es_ES
dc.contributor.author Keller, Matthias es_ES
dc.contributor.author Luik, Armin es_ES
dc.contributor.author Srutova, Martina es_ES
dc.date.accessioned 2016-03-15T08:54:56Z
dc.date.available 2016-03-15T08:54:56Z
dc.date.issued 2015-11
dc.identifier.issn 1099-4300
dc.identifier.uri http://hdl.handle.net/10251/61865
dc.description.abstract Atrial fibrillation (AF) is the most commonly clinically-encountered arrhythmia. Catheter ablation of AF is mainly based on trigger elimination and modification of the AF substrate. Substrate mapping ablation of complex fractionated atrial electrograms (CFAEs) has emerged to be a promising technique. To improve substrate mapping based on CFAE analysis, automatic detection algorithms need to be developed in order to simplify and accelerate the ablation procedures. According to the latest studies, the level of fractionation has been shown to be promisingly well estimated from CFAE measured during radio frequency (RF) ablation of AF. The nature of CFAE is generally nonlinear and nonstationary, so the use of complexity measures is considered to be the appropriate technique for the analysis of AF records. This work proposes the use of sample entropy (SampEn), not only as a way to discern between non-fractionated and fractionated atrial electrograms (A-EGM), but also as a tool for characterizing the degree of A-EGM regularity, which is linked to changes in the AF substrate and to heart tissue damage. The use of SampEn combined with a blind parameter estimation optimization process enables the classification between CFAE and non-CFAE with statistical significance (p < 0:001), 0.89 area under the ROC, 86% specificity and 77% sensitivity over a mixed database of A-EGM combined from two independent CFAE signal databases, recorded during RF ablation of AF in two EU countries (542 signals in total). On the basis of the results obtained in this study, it can be suggested that the use of SampEn is suitable for real-time support during navigation of RF ablation of AF, as only 1.5 seconds of signal segments need to be analyzed. es_ES
dc.description.sponsorship This work has been supported by the Spanish Ministry of Science and Innovation, Research Project TEC 2009-14222, by the Ministry of Education Youth and Sports of the Czech Republic, the Grant Agency of the Czech Technical University in Prague No. SGS13/203/OHK3/3T/13 and by the Czech Science 300 Foundation post-doctoral GACR research project GACR #P103/11/P106. en_EN
dc.language Inglés es_ES
dc.publisher MDPI es_ES
dc.relation.ispartof Entropy es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Atrial fibrillation es_ES
dc.subject Catheter ablation es_ES
dc.subject Complex fractionated atrial electrograms es_ES
dc.subject Sample entropy es_ES
dc.subject Signal classification es_ES
dc.subject.classification ARQUITECTURA Y TECNOLOGIA DE COMPUTADORES es_ES
dc.title Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/e17117493
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//TEC2009-14222/ES/Interpretacion Y Caracterizacion De Metodos De Analisis De Complejidad En El Contexto Del Procesado Biomedico De La Señal/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/CVUT//SGS13%2F203%2FOHK3%2F3T%2F13/CZ/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GACR//P103%1F11%2FP106/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario Mixto Tecnológico de Informática - Institut Universitari Mixt Tecnològic d'Informàtica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors es_ES
dc.description.bibliographicCitation Cirugeda Roldán, EM.; Novak, D.; Kremen, V.; Cuesta Frau, D.; Keller, M.; Luik, A.; Srutova, M. (2015). Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study. Entropy. 17(11):7493-7509. https://doi.org/10.3390/e17117493 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.3390/e17117493 es_ES
dc.description.upvformatpinicio 7493 es_ES
dc.description.upvformatpfin 7509 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 17 es_ES
dc.description.issue 11 es_ES
dc.relation.senia 299164 es_ES
dc.identifier.eissn 1099-4300
dc.contributor.funder Czech Technical University in Prague es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Czech Science Foundation es_ES
dc.contributor.funder Ministry of Education, Youth and Sport of the Czech Republic es_ES
dc.description.references Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., … Clémenty, J. (1998). Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins. New England Journal of Medicine, 339(10), 659-666. doi:10.1056/nejm199809033391003 es_ES
dc.description.references Nademanee, K., Schwab, M., Porath, J., & Abbo, A. (2006). How to perform electrogram-guided atrial fibrillation ablation. Heart Rhythm, 3(8), 981-984. doi:10.1016/j.hrthm.2006.03.018 es_ES
dc.description.references PORTER, M., SPEAR, W., AKAR, J. G., HELMS, R., BRYSIEWICZ, N., SANTUCCI, P., & WILBER, D. J. (2008). Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated Electrograms. Journal of Cardiovascular Electrophysiology, 19(6), 613-620. doi:10.1111/j.1540-8167.2008.01189.x es_ES
dc.description.references Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., … Jaïs, P. (2006). Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation. Circulation, 113(5), 616-625. doi:10.1161/circulationaha.105.546648 es_ES
dc.description.references Schmitt, C., Ndrepepa, G., Weber, S., Schmieder, S., Weyerbrock, S., Schneider, M., … Schömig, A. (2002). Biatrial multisite mapping of atrial premature complexes triggering onset of atrial fibrillation. The American Journal of Cardiology, 89(12), 1381-1387. doi:10.1016/s0002-9149(02)02350-0 es_ES
dc.description.references NDREPEPA, G., KARCH, M. R., SCHNEIDER, M. A. E., WEYERBROCK, S., SCHREIECK, J., DEISENHOFER, I., … SCHMITT, C. (2002). Characterization of Paroxysmal and Persistent Atrial Fibrillation in the Human Left Atrium During Initiation and Sustained Episodes. Journal of Cardiovascular Electrophysiology, 13(6), 525-532. doi:10.1046/j.1540-8167.2002.00525.x es_ES
dc.description.references Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., … Ngarmukos, T. (2004). A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. Journal of the American College of Cardiology, 43(11), 2044-2053. doi:10.1016/j.jacc.2003.12.054 es_ES
dc.description.references Oral, H., Chugh, A., Good, E., Wimmer, A., Dey, S., Gadeela, N., … Morady, F. (2007). Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms. Circulation, 115(20), 2606-2612. doi:10.1161/circulationaha.107.691386 es_ES
dc.description.references Kumagai, K. (2007). Patterns of activation in human atrial fibrillation. Heart Rhythm, 4(3), S7-S12. doi:10.1016/j.hrthm.2006.12.013 es_ES
dc.description.references Mainardi, L. T., Corino, V. D., Lombardi, L., Tondo, C., Mantica, M., Lombardi, F., & Cerutti, S. (2004). BioMedical Engineering OnLine, 3(1), 37. doi:10.1186/1475-925x-3-37 es_ES
dc.description.references RAVELLI, F., FAES, L., SANDRINI, L., GAITA, F., ANTOLINI, R., SCAGLIONE, M., & NOLLO, G. (2005). Wave Similarity Mapping Shows the Spatiotemporal Distribution of Fibrillatory Wave Complexity in the Human Right Atrium During Paroxysmal and Chronic Atrial Fibrillation. Journal of Cardiovascular Electrophysiology, 16(10), 1071-1076. doi:10.1111/j.1540-8167.2005.50008.x es_ES
dc.description.references NG, J., & GOLDBERGER, J. J. (2007). Understanding and Interpreting Dominant Frequency Analysis of AF Electrograms. Journal of Cardiovascular Electrophysiology, 18(6), 680-685. doi:10.1111/j.1540-8167.2007.00832.x es_ES
dc.description.references Takahashi, Y., O’Neill, M. D., Hocini, M., Dubois, R., Matsuo, S., Knecht, S., … Haïssaguerre, M. (2008). Characterization of Electrograms Associated With Termination of Chronic Atrial Fibrillation by Catheter Ablation. Journal of the American College of Cardiology, 51(10), 1003-1010. doi:10.1016/j.jacc.2007.10.056 es_ES
dc.description.references Křemen, V., Lhotská, L., Macaš, M., Čihák, R., Vančura, V., Kautzner, J., & Wichterle, D. (2008). A new approach to automated assessment of fractionation of endocardial electrograms during atrial fibrillation. Physiological Measurement, 29(12), 1371-1381. doi:10.1088/0967-3334/29/12/002 es_ES
dc.description.references Ciaccio, E. J., Biviano, A. B., Whang, W., Gambhir, A., & Garan, H. (2010). Different characteristics of complex fractionated atrial electrograms in acute paroxysmal versus long-standing persistent atrial fibrillation. Heart Rhythm, 7(9), 1207-1215. doi:10.1016/j.hrthm.2010.06.018 es_ES
dc.description.references LIN, Y.-J., LO, M.-T., LIN, C., CHANG, S.-L., LO, L.-W., HU, Y.-F., … CHEN, S.-A. (2012). Nonlinear Analysis of Fibrillatory Electrogram Similarity to Optimize the Detection of Complex Fractionated Electrograms During Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology, 24(3), 280-289. doi:10.1111/jce.12019 es_ES
dc.description.references NG, J., BORODYANSKIY, A. I., CHANG, E. T., VILLUENDAS, R., DIBS, S., KADISH, A. H., & GOLDBERGER, J. J. (2010). Measuring the Complexity of Atrial Fibrillation Electrograms. Journal of Cardiovascular Electrophysiology, 21(6), 649-655. doi:10.1111/j.1540-8167.2009.01695.x es_ES
dc.description.references Ganesan, A. N., Kuklik, P., Lau, D. H., Brooks, A. G., Baumert, M., Lim, W. W., … Sanders, P. (2013). Bipolar Electrogram Shannon Entropy at Sites of Rotational Activation. Circulation: Arrhythmia and Electrophysiology, 6(1), 48-57. doi:10.1161/circep.112.976654 es_ES
dc.description.references Jacquemet, V., & Henriquez, C. S. (2009). Genesis of complex fractionated atrial electrograms in zones of slow conduction: A computer model of microfibrosis. Heart Rhythm, 6(6), 803-810. doi:10.1016/j.hrthm.2009.02.026 es_ES
dc.description.references Jadidi, A. S., Duncan, E., Miyazaki, S., Lellouche, N., Shah, A. J., Forclaz, A., … Jaïs, P. (2012). Functional Nature of Electrogram Fractionation Demonstrated by Left Atrial High-Density Mapping. Circulation: Arrhythmia and Electrophysiology, 5(1), 32-42. doi:10.1161/circep.111.964197 es_ES
dc.description.references Ferrario, M., Signorini, M. G., Magenes, G., & Cerutti, S. (2006). Comparison of Entropy-Based Regularity Estimators: Application to the Fetal Heart Rate Signal for the Identification of Fetal Distress. IEEE Transactions on Biomedical Engineering, 53(1), 119-125. doi:10.1109/tbme.2005.859809 es_ES
dc.description.references Lewis, M. J., & Short, A. L. (2007). Sample entropy of electrocardiographic RR and QT time-series data during rest and exercise. Physiological Measurement, 28(6), 731-744. doi:10.1088/0967-3334/28/6/011 es_ES
dc.description.references Al-Angari, H. M., & Sahakian, A. V. (2007). Use of Sample Entropy Approach to Study Heart Rate Variability in Obstructive Sleep Apnea Syndrome. IEEE Transactions on Biomedical Engineering, 54(10), 1900-1904. doi:10.1109/tbme.2006.889772 es_ES
dc.description.references Lake, D. E., Richman, J. S., Griffin, M. P., & Moorman, J. R. (2002). Sample entropy analysis of neonatal heart rate variability. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 283(3), R789-R797. doi:10.1152/ajpregu.00069.2002 es_ES
dc.description.references Cervigón, R., Moreno, J., Reilly, R. B., Millet, J., Pérez-Villacastín, J., & Castells, F. (2010). Entropy measurements in paroxysmal and persistent atrial fibrillation. Physiological Measurement, 31(7), 1011-1020. doi:10.1088/0967-3334/31/7/010 es_ES
dc.description.references Alcaraz, R., & Rieta, J. J. (2009). The application of nonlinear metrics to assess organization differences in short recordings of paroxysmal and persistent atrial fibrillation. Physiological Measurement, 31(1), 115-130. doi:10.1088/0967-3334/31/1/008 es_ES
dc.description.references Orozco-Duque, A., Novak, D., Kremen, V., & Bustamante, J. (2015). Multifractal analysis for grading complex fractionated electrograms in atrial fibrillation. Physiological Measurement, 36(11), 2269-2284. doi:10.1088/0967-3334/36/11/2269 es_ES
dc.description.references Ugarte, J. P., Orozco-Duque, A., Tobón, C., Kremen, V., Novak, D., Saiz, J., … Bustamante, J. (2014). Dynamic Approximate Entropy Electroanatomic Maps Detect Rotors in a Simulated Atrial Fibrillation Model. PLoS ONE, 9(12), e114577. doi:10.1371/journal.pone.0114577 es_ES
dc.description.references Richman, J. S., & Moorman, J. R. (2000). Physiological time-series analysis using approximate entropy and sample entropy. American Journal of Physiology-Heart and Circulatory Physiology, 278(6), H2039-H2049. doi:10.1152/ajpheart.2000.278.6.h2039 es_ES
dc.description.references STILES, M. K., BROOKS, A. G., JOHN, B., WILSON, L., KUKLIK, P., DIMITRI, H., … SANDERS, P. (2008). The Effect of Electrogram Duration on Quantification of Complex Fractionated Atrial Electrograms and Dominant Frequency. Journal of Cardiovascular Electrophysiology, 19(3), 252-258. doi:10.1111/j.1540-8167.2007.01034.x es_ES
dc.description.references Verma, A., Novak, P., Macle, L., Whaley, B., Beardsall, M., Wulffhart, Z., & Khaykin, Y. (2008). A prospective, multicenter evaluation of ablating complex fractionated electrograms (CFEs) during atrial fibrillation (AF) identified by an automated mapping algorithm: Acute effects on AF and efficacy as an adjuvant strategy. Heart Rhythm, 5(2), 198-205. doi:10.1016/j.hrthm.2007.09.027 es_ES
dc.description.references Schilling, C., Keller, M., Scherr, D., Oesterlein, T., Haïssaguerre, M., Schmitt, C., … Luik, A. (2015). Fuzzy decision tree to classify complex fractionated atrial electrograms. Biomedical Engineering / Biomedizinische Technik, 60(3). doi:10.1515/bmt-2014-0110 es_ES
dc.description.references Garcia-Gonzalez, M. A., Fernandez-Chimeno, M., & Ramos-Castro, J. (2009). Errors in the Estimation of Approximate Entropy and Other Recurrence-Plot-Derived Indices Due to the Finite Resolution of RR Time Series. IEEE Transactions on Biomedical Engineering, 56(2), 345-351. doi:10.1109/tbme.2008.2005951 es_ES
dc.description.references Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994). High-density mapping of electrically induced atrial fibrillation in humans. Circulation, 89(4), 1665-1680. doi:10.1161/01.cir.89.4.1665 es_ES
dc.description.references Lake, D. E., & Moorman, J. R. (2011). Accurate estimation of entropy in very short physiological time series: the problem of atrial fibrillation detection in implanted ventricular devices. American Journal of Physiology-Heart and Circulatory Physiology, 300(1), H319-H325. doi:10.1152/ajpheart.00561.2010 es_ES
dc.description.references HOEKSTRA, B. P. T., DIKS, C. G. H., ALLESSIE, M. A., & GOEDB, J. (1995). Nonlinear Analysis of Epicardial Atrial Electrograms of Electrically Induced Atrial Fibrillation in Man. Journal of Cardiovascular Electrophysiology, 6(6), 419-440. doi:10.1111/j.1540-8167.1995.tb00416.x es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem