dc.description.abstract | Atrial fibrillation (AF) is the most commonly clinically-encountered arrhythmia. Catheter ablation of AF is mainly based on trigger elimination and modification of the AF substrate. Substrate mapping ablation of complex fractionated atrial electrograms (CFAEs) has emerged to be a promising technique. To improve substrate mapping based on CFAE analysis, automatic detection algorithms need to be developed in order to simplify and accelerate the ablation procedures. According to the latest studies, the level of fractionation has been shown to be promisingly well estimated from CFAE measured during radio frequency (RF) ablation of AF. The nature of CFAE is generally nonlinear and nonstationary, so the use of complexity measures is considered to be the appropriate technique for the analysis of AF records. This work proposes the use of sample entropy (SampEn), not only as a way to discern between non-fractionated and fractionated atrial electrograms (A-EGM), but also as a tool for characterizing the degree of A-EGM regularity, which is linked to changes in the AF substrate and to heart tissue damage. The use of SampEn combined with a blind parameter estimation optimization process enables the classification between CFAE and non-CFAE with statistical significance (p < 0:001), 0.89 area under the ROC, 86% specificity and 77% sensitivity over a mixed database of A-EGM combined from two independent CFAE signal databases, recorded during RF ablation of AF in two EU countries (542 signals in total). On the basis of the results obtained in this study, it can be suggested that the use of SampEn is suitable for real-time support during navigation of RF ablation of AF, as only 1.5 seconds of signal segments need to be analyzed. | es_ES |
dc.description.sponsorship | This work has been supported by the Spanish Ministry of Science and Innovation, Research Project TEC 2009-14222, by the Ministry of Education Youth and Sports of the Czech Republic, the Grant Agency of the Czech Technical University in Prague No. SGS13/203/OHK3/3T/13 and by the Czech Science 300 Foundation post-doctoral GACR research project GACR #P103/11/P106. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation.ispartof | Entropy | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Atrial fibrillation | es_ES |
dc.subject | Catheter ablation | es_ES |
dc.subject | Complex fractionated atrial electrograms | es_ES |
dc.subject | Sample entropy | es_ES |
dc.subject | Signal classification | es_ES |
dc.subject.classification | ARQUITECTURA Y TECNOLOGIA DE COMPUTADORES | es_ES |
dc.title | Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/e17117493 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//TEC2009-14222/ES/Interpretacion Y Caracterizacion De Metodos De Analisis De Complejidad En El Contexto Del Procesado Biomedico De La Señal/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/CVUT//SGS13%2F203%2FOHK3%2F3T%2F13/CZ/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GACR//P103%1F11%2FP106/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto Tecnológico de Informática - Institut Universitari Mixt Tecnològic d'Informàtica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors | es_ES |
dc.description.bibliographicCitation | Cirugeda Roldán, EM.; Novak, D.; Kremen, V.; Cuesta Frau, D.; Keller, M.; Luik, A.; Srutova, M. (2015). Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study. Entropy. 17(11):7493-7509. https://doi.org/10.3390/e17117493 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.3390/e17117493 | es_ES |
dc.description.upvformatpinicio | 7493 | es_ES |
dc.description.upvformatpfin | 7509 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 17 | es_ES |
dc.description.issue | 11 | es_ES |
dc.relation.senia | 299164 | es_ES |
dc.identifier.eissn | 1099-4300 | |
dc.contributor.funder | Czech Technical University in Prague | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Czech Science Foundation | es_ES |
dc.contributor.funder | Ministry of Education, Youth and Sport of the Czech Republic | es_ES |
dc.description.references | Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., … Clémenty, J. (1998). Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins. New England Journal of Medicine, 339(10), 659-666. doi:10.1056/nejm199809033391003 | es_ES |
dc.description.references | Nademanee, K., Schwab, M., Porath, J., & Abbo, A. (2006). How to perform electrogram-guided atrial fibrillation ablation. Heart Rhythm, 3(8), 981-984. doi:10.1016/j.hrthm.2006.03.018 | es_ES |
dc.description.references | PORTER, M., SPEAR, W., AKAR, J. G., HELMS, R., BRYSIEWICZ, N., SANTUCCI, P., & WILBER, D. J. (2008). Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated Electrograms. Journal of Cardiovascular Electrophysiology, 19(6), 613-620. doi:10.1111/j.1540-8167.2008.01189.x | es_ES |
dc.description.references | Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., … Jaïs, P. (2006). Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation. Circulation, 113(5), 616-625. doi:10.1161/circulationaha.105.546648 | es_ES |
dc.description.references | Schmitt, C., Ndrepepa, G., Weber, S., Schmieder, S., Weyerbrock, S., Schneider, M., … Schömig, A. (2002). Biatrial multisite mapping of atrial premature complexes triggering onset of atrial fibrillation. The American Journal of Cardiology, 89(12), 1381-1387. doi:10.1016/s0002-9149(02)02350-0 | es_ES |
dc.description.references | NDREPEPA, G., KARCH, M. R., SCHNEIDER, M. A. E., WEYERBROCK, S., SCHREIECK, J., DEISENHOFER, I., … SCHMITT, C. (2002). Characterization of Paroxysmal and Persistent Atrial Fibrillation in the Human Left Atrium During Initiation and Sustained Episodes. Journal of Cardiovascular Electrophysiology, 13(6), 525-532. doi:10.1046/j.1540-8167.2002.00525.x | es_ES |
dc.description.references | Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., … Ngarmukos, T. (2004). A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. Journal of the American College of Cardiology, 43(11), 2044-2053. doi:10.1016/j.jacc.2003.12.054 | es_ES |
dc.description.references | Oral, H., Chugh, A., Good, E., Wimmer, A., Dey, S., Gadeela, N., … Morady, F. (2007). Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms. Circulation, 115(20), 2606-2612. doi:10.1161/circulationaha.107.691386 | es_ES |
dc.description.references | Kumagai, K. (2007). Patterns of activation in human atrial fibrillation. Heart Rhythm, 4(3), S7-S12. doi:10.1016/j.hrthm.2006.12.013 | es_ES |
dc.description.references | Mainardi, L. T., Corino, V. D., Lombardi, L., Tondo, C., Mantica, M., Lombardi, F., & Cerutti, S. (2004). BioMedical Engineering OnLine, 3(1), 37. doi:10.1186/1475-925x-3-37 | es_ES |
dc.description.references | RAVELLI, F., FAES, L., SANDRINI, L., GAITA, F., ANTOLINI, R., SCAGLIONE, M., & NOLLO, G. (2005). Wave Similarity Mapping Shows the Spatiotemporal Distribution of Fibrillatory Wave Complexity in the Human Right Atrium During Paroxysmal and Chronic Atrial Fibrillation. Journal of Cardiovascular Electrophysiology, 16(10), 1071-1076. doi:10.1111/j.1540-8167.2005.50008.x | es_ES |
dc.description.references | NG, J., & GOLDBERGER, J. J. (2007). Understanding and Interpreting Dominant Frequency Analysis of AF Electrograms. Journal of Cardiovascular Electrophysiology, 18(6), 680-685. doi:10.1111/j.1540-8167.2007.00832.x | es_ES |
dc.description.references | Takahashi, Y., O’Neill, M. D., Hocini, M., Dubois, R., Matsuo, S., Knecht, S., … Haïssaguerre, M. (2008). Characterization of Electrograms Associated With Termination of Chronic Atrial Fibrillation by Catheter Ablation. Journal of the American College of Cardiology, 51(10), 1003-1010. doi:10.1016/j.jacc.2007.10.056 | es_ES |
dc.description.references | Křemen, V., Lhotská, L., Macaš, M., Čihák, R., Vančura, V., Kautzner, J., & Wichterle, D. (2008). A new approach to automated assessment of fractionation of endocardial electrograms during atrial fibrillation. Physiological Measurement, 29(12), 1371-1381. doi:10.1088/0967-3334/29/12/002 | es_ES |
dc.description.references | Ciaccio, E. J., Biviano, A. B., Whang, W., Gambhir, A., & Garan, H. (2010). Different characteristics of complex fractionated atrial electrograms in acute paroxysmal versus long-standing persistent atrial fibrillation. Heart Rhythm, 7(9), 1207-1215. doi:10.1016/j.hrthm.2010.06.018 | es_ES |
dc.description.references | LIN, Y.-J., LO, M.-T., LIN, C., CHANG, S.-L., LO, L.-W., HU, Y.-F., … CHEN, S.-A. (2012). Nonlinear Analysis of Fibrillatory Electrogram Similarity to Optimize the Detection of Complex Fractionated Electrograms During Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology, 24(3), 280-289. doi:10.1111/jce.12019 | es_ES |
dc.description.references | NG, J., BORODYANSKIY, A. I., CHANG, E. T., VILLUENDAS, R., DIBS, S., KADISH, A. H., & GOLDBERGER, J. J. (2010). Measuring the Complexity of Atrial Fibrillation Electrograms. Journal of Cardiovascular Electrophysiology, 21(6), 649-655. doi:10.1111/j.1540-8167.2009.01695.x | es_ES |
dc.description.references | Ganesan, A. N., Kuklik, P., Lau, D. H., Brooks, A. G., Baumert, M., Lim, W. W., … Sanders, P. (2013). Bipolar Electrogram Shannon Entropy at Sites of Rotational Activation. Circulation: Arrhythmia and Electrophysiology, 6(1), 48-57. doi:10.1161/circep.112.976654 | es_ES |
dc.description.references | Jacquemet, V., & Henriquez, C. S. (2009). Genesis of complex fractionated atrial electrograms in zones of slow conduction: A computer model of microfibrosis. Heart Rhythm, 6(6), 803-810. doi:10.1016/j.hrthm.2009.02.026 | es_ES |
dc.description.references | Jadidi, A. S., Duncan, E., Miyazaki, S., Lellouche, N., Shah, A. J., Forclaz, A., … Jaïs, P. (2012). Functional Nature of Electrogram Fractionation Demonstrated by Left Atrial High-Density Mapping. Circulation: Arrhythmia and Electrophysiology, 5(1), 32-42. doi:10.1161/circep.111.964197 | es_ES |
dc.description.references | Ferrario, M., Signorini, M. G., Magenes, G., & Cerutti, S. (2006). Comparison of Entropy-Based Regularity Estimators: Application to the Fetal Heart Rate Signal for the Identification of Fetal Distress. IEEE Transactions on Biomedical Engineering, 53(1), 119-125. doi:10.1109/tbme.2005.859809 | es_ES |
dc.description.references | Lewis, M. J., & Short, A. L. (2007). Sample entropy of electrocardiographic RR and QT time-series data during rest and exercise. Physiological Measurement, 28(6), 731-744. doi:10.1088/0967-3334/28/6/011 | es_ES |
dc.description.references | Al-Angari, H. M., & Sahakian, A. V. (2007). Use of Sample Entropy Approach to Study Heart Rate Variability in Obstructive Sleep Apnea Syndrome. IEEE Transactions on Biomedical Engineering, 54(10), 1900-1904. doi:10.1109/tbme.2006.889772 | es_ES |
dc.description.references | Lake, D. E., Richman, J. S., Griffin, M. P., & Moorman, J. R. (2002). Sample entropy analysis of neonatal heart rate variability. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 283(3), R789-R797. doi:10.1152/ajpregu.00069.2002 | es_ES |
dc.description.references | Cervigón, R., Moreno, J., Reilly, R. B., Millet, J., Pérez-Villacastín, J., & Castells, F. (2010). Entropy measurements in paroxysmal and persistent atrial fibrillation. Physiological Measurement, 31(7), 1011-1020. doi:10.1088/0967-3334/31/7/010 | es_ES |
dc.description.references | Alcaraz, R., & Rieta, J. J. (2009). The application of nonlinear metrics to assess organization differences in short recordings of paroxysmal and persistent atrial fibrillation. Physiological Measurement, 31(1), 115-130. doi:10.1088/0967-3334/31/1/008 | es_ES |
dc.description.references | Orozco-Duque, A., Novak, D., Kremen, V., & Bustamante, J. (2015). Multifractal analysis for grading complex fractionated electrograms in atrial fibrillation. Physiological Measurement, 36(11), 2269-2284. doi:10.1088/0967-3334/36/11/2269 | es_ES |
dc.description.references | Ugarte, J. P., Orozco-Duque, A., Tobón, C., Kremen, V., Novak, D., Saiz, J., … Bustamante, J. (2014). Dynamic Approximate Entropy Electroanatomic Maps Detect Rotors in a Simulated Atrial Fibrillation Model. PLoS ONE, 9(12), e114577. doi:10.1371/journal.pone.0114577 | es_ES |
dc.description.references | Richman, J. S., & Moorman, J. R. (2000). Physiological time-series analysis using approximate entropy and sample entropy. American Journal of Physiology-Heart and Circulatory Physiology, 278(6), H2039-H2049. doi:10.1152/ajpheart.2000.278.6.h2039 | es_ES |
dc.description.references | STILES, M. K., BROOKS, A. G., JOHN, B., WILSON, L., KUKLIK, P., DIMITRI, H., … SANDERS, P. (2008). The Effect of Electrogram Duration on Quantification of Complex Fractionated Atrial Electrograms and Dominant Frequency. Journal of Cardiovascular Electrophysiology, 19(3), 252-258. doi:10.1111/j.1540-8167.2007.01034.x | es_ES |
dc.description.references | Verma, A., Novak, P., Macle, L., Whaley, B., Beardsall, M., Wulffhart, Z., & Khaykin, Y. (2008). A prospective, multicenter evaluation of ablating complex fractionated electrograms (CFEs) during atrial fibrillation (AF) identified by an automated mapping algorithm: Acute effects on AF and efficacy as an adjuvant strategy. Heart Rhythm, 5(2), 198-205. doi:10.1016/j.hrthm.2007.09.027 | es_ES |
dc.description.references | Schilling, C., Keller, M., Scherr, D., Oesterlein, T., Haïssaguerre, M., Schmitt, C., … Luik, A. (2015). Fuzzy decision tree to classify complex fractionated atrial electrograms. Biomedical Engineering / Biomedizinische Technik, 60(3). doi:10.1515/bmt-2014-0110 | es_ES |
dc.description.references | Garcia-Gonzalez, M. A., Fernandez-Chimeno, M., & Ramos-Castro, J. (2009). Errors in the Estimation of Approximate Entropy and Other Recurrence-Plot-Derived Indices Due to the Finite Resolution of RR Time Series. IEEE Transactions on Biomedical Engineering, 56(2), 345-351. doi:10.1109/tbme.2008.2005951 | es_ES |
dc.description.references | Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994). High-density mapping of electrically induced atrial fibrillation in humans. Circulation, 89(4), 1665-1680. doi:10.1161/01.cir.89.4.1665 | es_ES |
dc.description.references | Lake, D. E., & Moorman, J. R. (2011). Accurate estimation of entropy in very short physiological time series: the problem of atrial fibrillation detection in implanted ventricular devices. American Journal of Physiology-Heart and Circulatory Physiology, 300(1), H319-H325. doi:10.1152/ajpheart.00561.2010 | es_ES |
dc.description.references | HOEKSTRA, B. P. T., DIKS, C. G. H., ALLESSIE, M. A., & GOEDB, J. (1995). Nonlinear Analysis of Epicardial Atrial Electrograms of Electrically Induced Atrial Fibrillation in Man. Journal of Cardiovascular Electrophysiology, 6(6), 419-440. doi:10.1111/j.1540-8167.1995.tb00416.x | es_ES |