Mostrar el registro sencillo del ítem
dc.contributor.author | Prats Boluda, Gema | es_ES |
dc.contributor.author | Gil Sánchez, Luís | es_ES |
dc.contributor.author | Ye Lin, Yiyao | es_ES |
dc.contributor.author | Ibáñez Civera, Francisco Javier | es_ES |
dc.contributor.author | Garcia Casado, Francisco Javier | es_ES |
dc.contributor.author | García Breijo, Eduardo | es_ES |
dc.date.accessioned | 2016-04-08T08:00:42Z | |
dc.date.available | 2016-04-08T08:00:42Z | |
dc.date.issued | 2012 | |
dc.identifier.issn | 1877-7058 | |
dc.identifier.uri | http://hdl.handle.net/10251/62357 | |
dc.description.abstract | [EN] Non-invasive bioelectrical recordings are usually carried out by using monopolar or bipolar disc electrodes. The poor spatial resolution is one important disadvantage of this kind of electrodes tending to pick up physiological interferences. Concentric ring electrodes have already been implemented in rigid substrates to increase the spatial resolution in the recording of bioelectrical signals such as the electrocardiography (ECG) or the electroencephalography (EEG). Our goal was to develop and test a new modular active sensor made up of a disposable sensing part with concentric ring electrodes printed on a flexible substrate by thick-film technology connected to a battery powered signal conditioning circuit, and to compare it to rigid conventional concentric ring electrodes implemented on printed circuit board. Simultaneous ECG recordings were carried out using both flexible and rigid electrodes. Results show that flexible concentric ring electrodes present lower skin-electrode contact impedance, higher amplitude and lower baseline wander than the rigid ones. | es_ES |
dc.description.sponsorship | Authors ackowledge financial support from the Spanish Government and its MICINN (MAT2009-14564-C04-02), MICINN (TEC2010-16945), the Universitat Politècnia de Valencia trough Nuevas Líneas de Investigación Multidisciplinares (PAID-05-11) for their respective research fellowship | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Procedia Engineering | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Flexible electrode | es_ES |
dc.subject | Non invasive bioelectrical signal | es_ES |
dc.subject | Concentric ring electrode | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Flexible Concentric Ring Electrode for Non Invasive Bioelectrical Surface Recordings | es_ES |
dc.type | Artículo | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.identifier.doi | 10.1016/j.proeng.2012.09.373 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-02/ES/Aproximacion Al Biomimetismo Usando Lenguas Electronicas Y Narices Para La Deteccion De Explosivos Y Agentes Nerviosos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//TEC2010-16945/ES/APLICACION DE TECNICAS LAPLACIANAS PARA LA MONITORIZACION DE LA ACTIVIDAD ELECTRICA DEL MUSCULO LISO HUMANO: ENFASIS EN ELECTROHISTEROGRAMA/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//PAID-05-11/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano - Institut Interuniversitari d'Investigació en Bioenginyeria i Tecnologia Orientada a l'Ésser Humà | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Prats Boluda, G.; Gil Sánchez, L.; Ye Lin, Y.; Ibáñez Civera, FJ.; Garcia Casado, FJ.; García Breijo, E. (2012). Flexible Concentric Ring Electrode for Non Invasive Bioelectrical Surface Recordings. Procedia Engineering. 47:1223-1226. https://doi.org/10.1016/j.proeng.2012.09.373 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.proeng.2012.09.373 | es_ES |
dc.description.upvformatpinicio | 1223 | es_ES |
dc.description.upvformatpfin | 1226 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 47 | es_ES |
dc.relation.senia | 230608 | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | |
dc.contributor.funder | Universitat Politècnica de València |