Airborne pollutant emissions from naturally ventilated buildings: Proposed research directions

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Airborne pollutant emissions from naturally ventilated buildings: Proposed research directions

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Takai, Hisamitsu es_ES
dc.contributor.author Nimmermark, Sven es_ES
dc.contributor.author Banhazi, Thomas es_ES
dc.contributor.author Norton, Tomas es_ES
dc.contributor.author Jacobson, Larry D. es_ES
dc.contributor.author Calvet Sanz, Salvador es_ES
dc.contributor.author Hassouna, Melynda es_ES
dc.contributor.author Bjerg, Bjarne es_ES
dc.contributor.author Zhang, Guo-Qiang es_ES
dc.contributor.author Pedersen, Soeren es_ES
dc.contributor.author Kai, Peter es_ES
dc.contributor.author Wang, Kaiying es_ES
dc.contributor.author Berckmans, Daniel es_ES
dc.date.accessioned 2016-05-02T10:24:03Z
dc.date.available 2016-05-02T10:24:03Z
dc.date.issued 2013-11
dc.identifier.issn 1537-5110
dc.identifier.uri http://hdl.handle.net/10251/63322
dc.description.abstract The present article describes the current research focus and the future research trends associated with investigating emissions from naturally ventilated buildings as identified at the technical session entitled "Emission from naturally ventilated buildings (Measurement, modelling, reduction and assessment)", that was held during the International Commission of Agricultural and Biosystems Engineering (Commission Internationale du Genie Rural, CIGR) World Congress in Quebec, Canada, between the 13th and 18th June 2010. Current knowledge and measurement techniques can only provide reasonable estimates of emissions from naturally ventilated livestock buildings. Thus, further research and development are required. The goal is a point where measurements are precise enough to validate simulation models and to obtain more consistent and accurate emission estimates. To achieve this, better synergy between mathematical modelling, physical modelling and field measurements of ventilation rates in naturally ventilated livestock buildings is required. The review of research presented at the Quebec meeting identified the following intermediate goals: 1. Investigate and determine error sources and measurement inaccuracies. Error analysis might be necessary to interpret results and establish research priorities. 2. Develop intelligent ventilation control systems that can handle highly fluctuating ventilation conditions in naturally ventilated livestock buildings. 3. Develop practical field methods that can be used as reference standards. 4. Establish a dedicated facility that could be used to obtain precise reference measurements of ventilation rates in naturally ventilated building. To enable this, a parallel development of new technologies (instrumentation and methodology) is required. (C) 2013 Published by Elsevier Ltd on behalf of IAgrE. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Biosystems Engineering es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification PRODUCCION ANIMAL es_ES
dc.title Airborne pollutant emissions from naturally ventilated buildings: Proposed research directions es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.biosystemseng.2012.12.015
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ciencia y Tecnología Animal - Institut de Ciència i Tecnologia Animal es_ES
dc.description.bibliographicCitation Takai, H.; Nimmermark, S.; Banhazi, T.; Norton, T.; Jacobson, LD.; Calvet Sanz, S.; Hassouna, M.... (2013). Airborne pollutant emissions from naturally ventilated buildings: Proposed research directions. Biosystems Engineering. 116(3):214-220. doi:10.1016/j.biosystemseng.2012.12.015 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.biosystemseng.2012.12.015 es_ES
dc.description.upvformatpinicio 214 es_ES
dc.description.upvformatpfin 220 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 116 es_ES
dc.description.issue 3 es_ES
dc.relation.senia 249849
dc.identifier.eissn 1537-5129