Measuring gas emissions from livestock buildings: A review on uncertainty analysis and error sources

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Measuring gas emissions from livestock buildings: A review on uncertainty analysis and error sources

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Calvet Sanz, Salvador es_ES
dc.contributor.author Gates, Richard S. es_ES
dc.contributor.author Zhang, GuoQiang es_ES
dc.contributor.author Estellés, F. es_ES
dc.contributor.author Ogink, Nico W. M. es_ES
dc.contributor.author Pedersen, Soren es_ES
dc.contributor.author Berckmans, Daniel es_ES
dc.date.accessioned 2016-05-02T10:41:31Z
dc.date.available 2016-05-02T10:41:31Z
dc.date.issued 2013-11
dc.identifier.issn 1537-5110
dc.identifier.uri http://hdl.handle.net/10251/63325
dc.description.abstract Measuring gaseous and particulate emissions from livestock houses has been the subject of intensive research over the past two decades. Currently, there is general agreement regarding appropriate methods to measure emissions from mechanically ventilated buildings. However, measuring emissions from naturally ventilated buildings remains an elusive target primarily because there is no reference method for measuring building ventilation rate. Ventilation rates and thus building emissions estimates for naturally ventilated buildings are likely to contain greater errors compared with those from mechanically ventilated buildings. This work reviews the origin and magnitude of errors associated with emissions from naturally ventilated buildings as compared to those typically found in mechanical ventilation. Firstly, some general concepts of error analysis are detailed. Then, typical errors found in the literature for each measurement technique are reviewed, and potential sources of relevant systematic and random errors are identified. The emission standard uncertainty in mechanical ventilation is at best 10% or more of the measured value, whereas in natural ventilation it may be considerably higher and there may also be significant unquantifiable biases. A reference method is necessary to obtain accurate emissions estimates, and for naturally ventilated structures this suggests the need for a new means of ventilation measurement. The results obtained from the analysis of information in this review will be helpful to establish research priorities, and to optimize research efforts in terms of quality of emission measurements. (C) 2012 IAgrE. Published by Elsevier Ltd. All rights reserved. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Biosystems Engineering es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Gas emissions es_ES
dc.subject Livestock housing es_ES
dc.subject Random error es_ES
dc.subject Systematic error es_ES
dc.subject Error analysis es_ES
dc.subject Uncertainty es_ES
dc.subject Measuring ammonia emissions es_ES
dc.subject Fattening pig house es_ES
dc.subject Ventilation rate es_ES
dc.subject Carbon-Dioxide es_ES
dc.subject Broiler houses es_ES
dc.subject Air-flow es_ES
dc.subject Rates es_ES
dc.subject Poultry es_ES
dc.subject Manure es_ES
dc.subject Performance es_ES
dc.subject.classification PRODUCCION ANIMAL es_ES
dc.title Measuring gas emissions from livestock buildings: A review on uncertainty analysis and error sources es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.biosystemseng.2012.11.004
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ciencia y Tecnología Animal - Institut de Ciència i Tecnologia Animal es_ES
dc.description.bibliographicCitation Calvet Sanz, S.; Gates, RS.; Zhang, G.; Estellés, F.; Ogink, NWM.; Pedersen, S.; Berckmans, D. (2013). Measuring gas emissions from livestock buildings: A review on uncertainty analysis and error sources. Biosystems Engineering. 116:221-231. doi:10.1016/j.biosystemseng.2012.11.004 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.biosystemseng.2012.11.004 es_ES
dc.description.upvformatpinicio 221 es_ES
dc.description.upvformatpfin 231 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 116 es_ES
dc.relation.senia 250123 es_ES
dc.identifier.eissn 1537-5129


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem