Resumen:
|
The Manzanares River, located in Madrid (Spain), is the main water supplier of a highly populated region,
and it also receives wastewater from the same area. The effluents of eight Waste Water Treatment Plants
(WWTPs) ...[+]
The Manzanares River, located in Madrid (Spain), is the main water supplier of a highly populated region,
and it also receives wastewater from the same area. The effluents of eight Waste Water Treatment Plants
(WWTPs) downstream of the river, which represent 90% of the flow in the middle and lower parts of the
river, are the primary sources of water pollution. Although the situation has improved slightly in the last two
years, the water in the river is highly polluted, making it uninhabitable for aquatic life. Water quality
modelling is typically used to assess the effect of treatment improvements in water bodies. In this work, the
GESCAL module of the Aquatool Decision Support System Shell was used to simulate water quality in the
Manzanares River. GESCAL is appropriate for modelling in an integrated way water quality for whole water
resources systems, including reservoirs and rivers. A model was built that simulates conductivity,
phosphorous, carbonaceous organic matter, dissolved oxygen, organic nitrogen, ammonia, and nitrates.
The period from October 2006 to September 2008 was selected for calibration due to the many treatment
modifications that occurred during this time. An earlier and longer period, from October 2000 to September
2006, was used for validation. In addition, a daily model was used to analyse the robustness of the GESCAL
model. Once the GESCAL model was validated, different scenarios were considered and simulated. First,
different combinations of nutrient elimination among the different WWTPs were simulated, leading to the
conclusion that investments have to focus on three of the proposed WWTPs. Moreover, these treatments will
not be sufficient to maintain fish habitat conditions at all times. Additional measures, such as the increment
of the flow in the river or oxygen injection, were simulated. Incrementing the flow of the Manzanares River
has been shown to be an efficient means of increasing water quality, but this implies an increment in the risk
of water scarcity situations in the Madrid water supply system.