dc.description.abstract | Thick-film screen printed silver–silver chloride (Ag/AgCl) reference electrodes have been fabricated and investigated as an alternative to liquid electrolyte Ag/AgCl reference electrodes. The performance of the electrodes was examined with variations of the potassium chloride (KCl) concentration in the final (top) layer of the electrode. Also, different types of binder (glass and polymer) were tested for the underlying Ag/AgCl layer. The addition of another layer on top of the KCl containing salt matrix layer has been found to provide a better stability in varying concentrations of KCl test solutions. The electrodes were found to give a satisfactory performance when tested for stability in different pH solutions. | es_ES |
dc.description.sponsorship | The authors wish to thank the UK Environment Agency and the National Environmental Research Council for partially funding this work. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Sensors and Actuators A: Physical | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Silver/silver chloride | es_ES |
dc.subject | Reference electrodes | es_ES |
dc.subject | Thick-film | es_ES |
dc.subject | Solid state | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | The effect on performance of fabrication parameter variations of thick-film screen printed silver/silver chloride potentiometric reference electrodes | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.sna.2013.03.036 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Glanc, M.; Sophocleous, M.; Atkinson, J.; García-Breijo, E. (2013). The effect on performance of fabrication parameter variations of thick-film screen printed silver/silver chloride potentiometric reference electrodes. Sensors and Actuators A: Physical. 197:1-8. doi:10.1016/j.sna.2013.03.036 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.sna.2013.03.036 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 8 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 197 | es_ES |
dc.relation.senia | 258737 | es_ES |
dc.contributor.funder | Environment Agency, Reino Unido | es_ES |
dc.contributor.funder | Natural Environment Research Council, Reino Unido | es_ES |