Study of the influence of inner lining material on thermal stratification in a hot water storage tank

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Study of the influence of inner lining material on thermal stratification in a hot water storage tank

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Gasque Albalate, Maria es_ES
dc.contributor.author González Altozano, Pablo es_ES
dc.contributor.author Maurer, Daniel es_ES
dc.contributor.author Moncho Esteve, Ignacio José es_ES
dc.contributor.author Gutiérrez-Colomer, Rosa Penélope es_ES
dc.contributor.author Palau-Salvador, Guillermo es_ES
dc.contributor.author García-Mari, Eugenio es_ES
dc.date.accessioned 2016-05-16T11:45:11Z
dc.date.available 2016-05-16T11:45:11Z
dc.date.issued 2015-01-22
dc.identifier.issn 1359-4311
dc.identifier.uri http://hdl.handle.net/10251/64117
dc.description.abstract [EN] The present study has analysed the influence of thermal conductivity of the inner lining material on the stratification process in a hot water tank during thermal charge and the later standby period. This analysis has been carried out numerically by a three-dimensional Computational Fluid Dynamics (CFD) model. Experimental measurements of temperature profiles are used to select and verificate the model, and to later validate CFD simulations. With the validated model, temperature over time at several heights, temperature profiles, velocity contours, water streamtraces and temperature contours, are studied and compared for three different inner lining materials. The obtained results confirm that a weak conducting lining material favours energy storage in the tank and the thermal stratification of water during charge and subsequent standby period. The effect of the inner lining material on the energy accumulated in water and on the moment of energy (stratification) is potentially enhanced when the material's thermal conductivity diminishes. The use of insulating paints as inner lining for water storage tanks could be a possible solution to be studied and subsequently adopted in practice to improve the efficient use of energy in stored water. The analysis techniques employed prove most useful and enable the results to be compared and presented in a novel way. es_ES
dc.description.sponsorship This research was supported by the Plan Nacional de I+D+i del Ministerio de Ciencia e Innovacion (ENE2009-13376). The authors would like to thank L.H. Sanchis for his valuable and constructive suggestions during the planning and development of this research. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Applied Thermal Engineering es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Water stratification es_ES
dc.subject Thermal energy storage es_ES
dc.subject Inner lining material es_ES
dc.subject CFD es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.classification INGENIERIA AGROFORESTAL es_ES
dc.title Study of the influence of inner lining material on thermal stratification in a hot water storage tank es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.applthermaleng.2014.10.040
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//ENE2009-13376/ES/Estudio Y Caracterizacion De La Estratificacion En Los Acumuladores De Las Instalaciones Solares Termicas. Desarrollo De Un Acumulador Termico Estratificado Para Uso Solar/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Rural y Agroalimentaria - Departament d'Enginyeria Rural i Agroalimentària es_ES
dc.description.bibliographicCitation Gasque Albalate, M.; González Altozano, P.; Maurer, D.; Moncho Esteve, IJ.; Gutiérrez-Colomer, RP.; Palau-Salvador, G.; García-Mari, E. (2015). Study of the influence of inner lining material on thermal stratification in a hot water storage tank. Applied Thermal Engineering. 75:344-356. https://doi.org/10.1016/j.applthermaleng.2014.10.040 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://dx.doi.org/10.1016/j.applthermaleng.2014.10.040 es_ES
dc.description.upvformatpinicio 344 es_ES
dc.description.upvformatpfin 356 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 75 es_ES
dc.relation.senia 284103 es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)