American Water Works Association (AWWA), 1999. Water Meters - Selection, Installation, Testing, and Maintenance: Manual of Water Supply Practices (M6). Denver, CO: American Water Works Association.
American Water Works Association (AWWA), 2009. Water Audits and Loss Control Programs: AWWA Manual M36. Denver, CO: American Water Works Association.
Arregui, F.J., CabreraJr, E., and Cobacho, R., 2006a. Integrated water meter management. London: IWA Publishing.
[+]
American Water Works Association (AWWA), 1999. Water Meters - Selection, Installation, Testing, and Maintenance: Manual of Water Supply Practices (M6). Denver, CO: American Water Works Association.
American Water Works Association (AWWA), 2009. Water Audits and Loss Control Programs: AWWA Manual M36. Denver, CO: American Water Works Association.
Arregui, F.J., CabreraJr, E., and Cobacho, R., 2006a. Integrated water meter management. London: IWA Publishing.
Arregui, F. ., Cabrera, E., Cobacho, R., & García-Serra, J. (2006). Reducing Apparent Losses Caused By Meters Inaccuracies. Water Practice and Technology, 1(4). doi:10.2166/wpt.2006.093
Arregui, F.J., Martinez, B., Soriano, J., and Parra, J.C., 2009. Tools for improving decision making in water meter management. Proceedings of the 5th IWA Water Loss Reduction Specialist Conference (pp. 225–232). Cape Town, South Africa.
Barfuss, S.L., Johnson, M.C., and Neilsen, M.A., 2011. Accuracy of in-service water meters at low and high flow rates. Denver, CO: Water Research Foundation, Denver.
Blokker, E. J. M., Vreeburg, J. H. G., & van Dijk, J. C. (2010). Simulating Residential Water Demand with a Stochastic End-Use Model. Journal of Water Resources Planning and Management, 136(1), 19-26. doi:10.1061/(asce)wr.1943-5452.0000002
Bowen, P.T., Harp, J.F., Hendricks, J.E., and Shoeleh, M., 1991. Evaluating residential meter performance. Denver, CO: American Water Works Association Research Foundation.
Bowen, P.T., Harp, J.F., Baxter, J.W., and Shull, R.D., 1993. Residential water use patterns. Denver, CO: American Water Works Association Research Foundation.
Criminisi, A., Fontanazza, C. M., Freni, G., & Loggia, G. L. (2009). Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply. Water Science and Technology, 60(9), 2373-2382. doi:10.2166/wst.2009.423
DeOreo, W.B. and Mayer, P.W., 2013. Residential end uses of water study update. Denver, CO: Water Research Foundation.
ISO 4064-3, 1993. Measurement of water flow in closed conduits - meters for cold potable water. Part 3: Test methods and equipment. Geneva: International Organization for Standardization.
ISO 4064-1, 2005. Measurement of water flow in a fully charged closed conduit - meters for cold potable water and hot water. Part 1: Specifications. Geneva: International Organization for Standardization.
Lievers, C. and Barendregt, A., 2009. Implementation of intervention techniques to decrease commercial losses for Ghana. Proceedings of the 5th IWA Water Loss Reduction Specialist Conference (pp. 490–496). Cape Town, South Africa.
Male, J.W., Noss, R.R., and Moore, I.C., 1985. Identifying and Reducing Losses in Water Distribution Systems. Saddle River, NJ: Noyes Publications.
Mayer, P.W., DeOreo, W.B., Opitz, E.M., Kiefer, J.C., Davis, W.Y., Dziegielewski, B., and Nelson, J.O., 1999. Residential End Uses of Water. Denver, CO: AWWA Research Foundation and American Water Works Association.
Mutikanga, H. E., Sharma, S. K., & Vairavamoorthy, K. (2010). Assessment of apparent losses in urban water systems. Water and Environment Journal, 25(3), 327-335. doi:10.1111/j.1747-6593.2010.00225.x
Neilsen, M. A., Barfuss, S. L., & Johnson, M. C. (2011). Off-the-shelf accuracies of residential water meters. Journal - American Water Works Association, 103(9), 48-55. doi:10.1002/j.1551-8833.2011.tb11531.x
Richards, G. L., Johnson, M. C., & Barfuss, S. L. (2010). Apparent losses caused by water meter inaccuracies at ultralow flows. Journal - American Water Works Association, 102(5), 123-132. doi:10.1002/j.1551-8833.2010.tb10115.x
Rizzo, A. and Cilia, J., 2005. Quantifying meter under-registration caused by the ball valves of roof tanks (for indirect plumbing systems). Proceedings of the Leakage 2005 Conference, Halifax, Canada.
Thornton, J., Sturm, R., and Kunkel, G., 2008. Water Loss Control. New York: McGraw-Hill.
Woltmann, 2008. ITA. Valencia, Spain: Universitat PolitecnicaRetrieved from: http://www.ita.upv.es/software/presentacion-en.php.
Yaniv, S., 2012. Reduction of apparent losses using the UFR (Unmeasured-flow reducer): Case studies. Proceedings of the 5th IWA Specialist Conference on Efficient Water Use and Management. Hague, The Netherlands.
Yee, M. D. (1999). Economic analysis for replacing residential meters. Journal - American Water Works Association, 91(7), 72-77. doi:10.1002/j.1551-8833.1999.tb08666.x
[-]