Total harmonic distortion based method for linearity assessment in electrochemical systems in the context of EIS

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Total harmonic distortion based method for linearity assessment in electrochemical systems in the context of EIS

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Giner Sanz, Juan José es_ES
dc.contributor.author Ortega Navarro, Emma María es_ES
dc.contributor.author Pérez-Herranz, Valentín es_ES
dc.date.accessioned 2016-05-26T15:38:56Z
dc.date.available 2016-05-26T15:38:56Z
dc.date.issued 2015-12-20
dc.identifier.issn 0013-4686
dc.identifier.uri http://hdl.handle.net/10251/64818
dc.description.abstract Electrochemical Impedance Spectroscopy (EIS) is a widely used electrochemical measurement technique that has been used in a great spectrum of fields since it allows deconvolving the individual physic- chemical processes that take place in a given system. Ohm s generalized law, and thus the impedance concept, are only valid if 4 conditions are fulfilled: causality, finiteness, stationarity and linearity. In the case that any of these conditions is not achieved, the obtained impedance spectra will present distortions that may lead to biased or even erroneous results and conclusions. For this reason it is crucial to verify if the 4 conditions are fulfilled, before accepting the results extracted from impedance spectra. In this work, a linearity assessment quantitative method based in the total harmonic distortion (THD) parameter is presented and verified experimentally. The experimental validation of the implemented method showed that the implemented method is able to assess quantitatively the linearity of the system. In addition, it is also able to determine the threshold frequency above which the system will not present significant nonlinear effects even for large perturbation amplitudes. It was observed that the THD method is more sensitive to nonlinear effects than the spectra themselves. es_ES
dc.description.sponsorship The authors are very grateful to the Generalitat Valenciana for its economic support in form of Vali+d grant (Ref: ACIF-2013-268). en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Electrochimica Acta es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Electrochemical Impedance Spectroscopy es_ES
dc.subject Total harmonic distortion es_ES
dc.subject Linearity condition es_ES
dc.subject Spectrum validation es_ES
dc.subject Noise quantification es_ES
dc.subject.classification INGENIERIA QUIMICA es_ES
dc.title Total harmonic distortion based method for linearity assessment in electrochemical systems in the context of EIS es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.electacta.2015.10.152
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACIF%2F2013%2F268/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.description.bibliographicCitation Giner Sanz, JJ.; Ortega Navarro, EM.; Pérez-Herranz, V. (2015). Total harmonic distortion based method for linearity assessment in electrochemical systems in the context of EIS. Electrochimica Acta. 186:598-612. https://doi.org/10.1016/j.electacta.2015.10.152 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.electacta.2015.10.152 es_ES
dc.description.upvformatpinicio 598 es_ES
dc.description.upvformatpfin 612 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 186 es_ES
dc.relation.senia 297351 es_ES
dc.identifier.eissn 1873-3859
dc.contributor.funder Generalitat Valenciana es_ES