- -

Alteration of the P-wave non-linear dynamics near the onset of paroxysmal atrial fibrillation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Alteration of the P-wave non-linear dynamics near the onset of paroxysmal atrial fibrillation

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Martinez, Arturo es_ES
dc.contributor.author Abasolo, Daniel es_ES
dc.contributor.author Alcaraz, Raul es_ES
dc.contributor.author Rieta, J J es_ES
dc.date.accessioned 2016-05-27T14:35:03Z
dc.date.available 2016-05-27T14:35:03Z
dc.date.issued 2015-07
dc.identifier.issn 1350-4533
dc.identifier.uri http://hdl.handle.net/10251/64856
dc.description.abstract The analysis of P-wave variability from the electrocardiogram (ECG) has been suggested as an early predictor of the onset of paroxysmal atrial fibrillation (PAP). Hence, a preventive treatment could be used to avoid the loss of normal sinus rhythm, thus minimising health risks and improving the patient's quality of life. In these previous studies the variability of different temporal and morphological P-wave features has been only analysed in a linear fashion. However, the electrophysiological alteration occurring in the atria before the onset of PAF has to be considered as an inherently complex, chaotic and non-stationary process. This work analyses the presence of non-linear dynamics in the P-wave progression before the onset of PAF through the application of the central tendency measure (CTM), which is a non-linear metric summarising the degree of variability in a time series. Two hour-length ECG intervals just before the arrhythmia onset belonging to 46 different PAF patients were analysed. In agreement with the invasively observed inhomogeneous atrial conduction preceding the onset of PAF, CTM for all the considered P-wave features showed higher variability when the arrhythmia was closer to its onset. A diagnostic accuracy around 80% to discern between ECG segments far from PAF and close to PAP was obtained with the CTM of the metrics considered. This result was similar to previous P-wave variability methods based on linear approaches. However, the combination of linear and non-linear methods with a decision tree improved considerably their discriminant ability up to 90%, thus suggesting that both dynamics could coexist at the same time in the fragmented depolarisation of the atria preceding the arrhythmia. (C) 2015 IPEM. Published by Elsevier Ltd. All rights reserved. es_ES
dc.description.sponsorship This work was supported by the projects TEC2014-52250-R from the Spanish Ministry of Economy Competitiveness and PPII-2014-026-P from Junta de Comunidades de Castilla-La Mancha. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Medical Engineering and Physics es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Atrial fibrillation es_ES
dc.subject Central tendency measure es_ES
dc.subject Electrocardiogram es_ES
dc.subject Non-linear es_ES
dc.subject P-wave es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Alteration of the P-wave non-linear dynamics near the onset of paroxysmal atrial fibrillation es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.medengphy.2015.03.021
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//TEC2014-52250-R/ES/CUANTIFICACION DEL REMODELADO ELECTROANATOMICO EN ARRITMIAS CARDIACAS. DE LA INVESTIGACION A LA TERAPIA PERSONALIZADA./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/JCCM//PPII-2014-026-P/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Grupo de ingeniería en bioseñales e imagen radiológica es_ES
dc.description.bibliographicCitation Martinez, A.; Abasolo, D.; Alcaraz, R.; Rieta, JJ. (2015). Alteration of the P-wave non-linear dynamics near the onset of paroxysmal atrial fibrillation. Medical Engineering and Physics. 37(7):692-697. https://doi.org/10.1016/j.medengphy.2015.03.021 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.medengphy.2015.03.021 es_ES
dc.description.upvformatpinicio 692 es_ES
dc.description.upvformatpfin 697 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 37 es_ES
dc.description.issue 7 es_ES
dc.relation.senia 302092 es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.contributor.funder Junta de Comunidades de Castilla-La Mancha es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem