- -

Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Bustamante García, Eliseo es_ES
dc.contributor.author García Diego, Fernando Juan es_ES
dc.contributor.author Calvet Sanz, Salvador es_ES
dc.contributor.author Estellés, Fernando es_ES
dc.contributor.author Beltrán Medina, Pedro es_ES
dc.contributor.author Hospitaler Pérez, Antonio es_ES
dc.contributor.author Torres Salvador, Antonio Germán es_ES
dc.date.accessioned 2016-06-02T10:25:03Z
dc.date.available 2016-06-02T10:25:03Z
dc.date.issued 2013-05
dc.identifier.issn 1996-1073
dc.identifier.uri http://hdl.handle.net/10251/65107
dc.description © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). es_ES
dc.description.abstract [EN] Broiler production in modern poultry farms commonly uses mechanical ventilation systems. This mechanical ventilation requires an amount of electric energy and a high level of investment in technology. Nevertheless, broiler production is affected by periodic problems of mortality because of thermal stress, thus being crucial to explore the ventilation efficiency. In this article, we analyze a cross-mechanical ventilation system focusing on air velocity distribution. In this way, two methodologies were used to explore indoor environment in livestock buildings: Computational Fluid Dynamics (CFD) simulations and direct measurements for verification and validation (V&V) of CFD. In this study, a validation model using a Generalized Linear Model (GLM) was conducted to compare these methodologies. The results showed that both methodologies were similar in results: the average of air velocities values were 0.60 ± 0.56 m s−1 for CFD and 0.64 ± 0.54 m s−1 for direct measurements. In conclusion, the air velocity was not affected by the methodology (CFD or direct measurements), and the CFD simulations were therefore validated to analyze indoor environment of poultry farms and its operations. A better knowledge of the indoor environment may contribute to reduce the demand of electric energy, increasing benefits and improving the thermal comfort of broilers es_ES
dc.description.sponsorship This work was funded by the project GV04B-511 (Generalitat Valenciana, Spain) and by the Vicerrectorado of Investigacion of the Universitat Politecnica de Valencia (Programa de Apoyo a la Investigacion y Desarrollo Multidisciplinar Project PAID register 2614). en_EN
dc.language Inglés es_ES
dc.publisher MDPI es_ES
dc.relation.ispartof Energies es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Livestock building es_ES
dc.subject Design es_ES
dc.subject Efficiency es_ES
dc.subject Ventilation es_ES
dc.subject Cross-mechanical ventilation es_ES
dc.subject Poultry farm es_ES
dc.subject Broilers es_ES
dc.subject.classification PRODUCCION ANIMAL es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/en6052605
dc.relation.projectID info:eu-repo/grantAgreement/GVA//GV04B-511/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//2614/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal es_ES
dc.description.bibliographicCitation Bustamante García, E.; García Diego, FJ.; Calvet Sanz, S.; Estellés, F.; Beltrán Medina, P.; Hospitaler Pérez, A.; Torres Salvador, AG. (2013). Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm. Energies. 6(5):2605-2623. https://doi.org/10.3390/en6052605 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://dx.doi.org/10.3390/en6052605 es_ES
dc.description.upvformatpinicio 2605 es_ES
dc.description.upvformatpfin 2623 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 6 es_ES
dc.description.issue 5 es_ES
dc.relation.senia 249863 es_ES
dc.contributor.funder Universitat Politècnica de València es_ES
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem