Mostrar el registro sencillo del ítem
dc.contributor.author | Bustamante García, Eliseo | es_ES |
dc.contributor.author | García Diego, Fernando Juan | es_ES |
dc.contributor.author | Calvet Sanz, Salvador | es_ES |
dc.contributor.author | Estellés, Fernando | es_ES |
dc.contributor.author | Beltrán Medina, Pedro | es_ES |
dc.contributor.author | Hospitaler Pérez, Antonio | es_ES |
dc.contributor.author | Torres Salvador, Antonio Germán | es_ES |
dc.date.accessioned | 2016-06-02T10:25:03Z | |
dc.date.available | 2016-06-02T10:25:03Z | |
dc.date.issued | 2013-05 | |
dc.identifier.issn | 1996-1073 | |
dc.identifier.uri | http://hdl.handle.net/10251/65107 | |
dc.description | © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). | es_ES |
dc.description.abstract | [EN] Broiler production in modern poultry farms commonly uses mechanical ventilation systems. This mechanical ventilation requires an amount of electric energy and a high level of investment in technology. Nevertheless, broiler production is affected by periodic problems of mortality because of thermal stress, thus being crucial to explore the ventilation efficiency. In this article, we analyze a cross-mechanical ventilation system focusing on air velocity distribution. In this way, two methodologies were used to explore indoor environment in livestock buildings: Computational Fluid Dynamics (CFD) simulations and direct measurements for verification and validation (V&V) of CFD. In this study, a validation model using a Generalized Linear Model (GLM) was conducted to compare these methodologies. The results showed that both methodologies were similar in results: the average of air velocities values were 0.60 ± 0.56 m s−1 for CFD and 0.64 ± 0.54 m s−1 for direct measurements. In conclusion, the air velocity was not affected by the methodology (CFD or direct measurements), and the CFD simulations were therefore validated to analyze indoor environment of poultry farms and its operations. A better knowledge of the indoor environment may contribute to reduce the demand of electric energy, increasing benefits and improving the thermal comfort of broilers | es_ES |
dc.description.sponsorship | This work was funded by the project GV04B-511 (Generalitat Valenciana, Spain) and by the Vicerrectorado of Investigacion of the Universitat Politecnica de Valencia (Programa de Apoyo a la Investigacion y Desarrollo Multidisciplinar Project PAID register 2614). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation.ispartof | Energies | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Livestock building | es_ES |
dc.subject | Design | es_ES |
dc.subject | Efficiency | es_ES |
dc.subject | Ventilation | es_ES |
dc.subject | Cross-mechanical ventilation | es_ES |
dc.subject | Poultry farm | es_ES |
dc.subject | Broilers | es_ES |
dc.subject.classification | PRODUCCION ANIMAL | es_ES |
dc.subject.classification | INGENIERIA DE LA CONSTRUCCION | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/en6052605 | |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//GV04B-511/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//2614/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal | es_ES |
dc.description.bibliographicCitation | Bustamante García, E.; García Diego, FJ.; Calvet Sanz, S.; Estellés, F.; Beltrán Medina, P.; Hospitaler Pérez, A.; Torres Salvador, AG. (2013). Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD) in a Cross-Mechanically Ventilated Broiler Farm. Energies. 6(5):2605-2623. https://doi.org/10.3390/en6052605 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://dx.doi.org/10.3390/en6052605 | es_ES |
dc.description.upvformatpinicio | 2605 | es_ES |
dc.description.upvformatpfin | 2623 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 6 | es_ES |
dc.description.issue | 5 | es_ES |
dc.relation.senia | 249863 | es_ES |
dc.contributor.funder | Universitat Politècnica de València | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |