- -

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

Show full item record

Gonzalez Diaz, D.; Álvarez Puerta, V.; Borges, FIG.; Camargo, M.; Carcel, S.; Cebrian, S.; Cervera, A.... (2015). Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 804:8-24. https://doi.org/10.1016/j.nima.2015.08.033

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/66178

Files in this item

Item Metadata

Title: Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm
Author: Gonzalez Diaz, Diego Álvarez Puerta, Vicente Borges, F. I. G. Camargo, M. Carcel, S. Cebrian, S. Cervera, A. Conde, C. A. N. Dafni, T. Esteve Bosch, Raul Fernandes, L. M. P. Mora Mas, Francisco José Pérez Aparicio, José Luis Rodríguez Samaniego, Javier Toledo Alarcón, José Francisco
UPV Unit: Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures
Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
Issued date:
Abstract:
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated ...[+]
Subjects: Double-beta decay , Gamma and electron detection , Microbulk micromegas , Time projection chamber , High pressure Xenon-Trimehylamine , Penning-Fluorescent mixtures
Copyrigths: Reserva de todos los derechos
Source:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. (issn: 0168-9002 ) (eissn: 1872-9576 )
DOI: 10.1016/j.nima.2015.08.033
Publisher:
Elsevier
Publisher version: http://dx.doi.org/10.1016/j.nima.2015.08.033
Project ID:
info:eu-repo/grantAgreement/EC/FP7/339787/EU
European Research Council 339787-NEXT 240054-TREX
...[+]
info:eu-repo/grantAgreement/EC/FP7/339787/EU
info:eu-repo/grantAgreement/FCT/5876-PPCDTI/103860/PT
info:eu-repo/grantAgreement/EC/FP7/240054/EU
European Research Council 339787-NEXT 240054-TREX
Spanish Ministerio de Economia y Competitividad CSD2008-0037 (CUP) CSD2007-00042 (CPAN) FPA2008-03456 FPA2009-13697
Portuguese Fundacao para a Ciencia e a Tecnologia
European FEDER PPTDC/FIS/103860/2008
US Department Of Energy DE-AC02-05CH11231
[-]
Thanks:
The NEXT collaboration acknowledges funding support from the following agencies and institutions: European Research Council under Advanced Grant 339787-NEXT and Starting Grant 240054-TREX, Spanish Ministerio de Economia y ...[+]
Type: Artículo

This item appears in the following Collection(s)

Show full item record