Impact of the throat sizing on the operating parameters in an experimental fixed bed gasifier: Analysis, evaluation and testing

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Impact of the throat sizing on the operating parameters in an experimental fixed bed gasifier: Analysis, evaluation and testing

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Montuori, Lina es_ES
dc.contributor.author Vargas Salgado, Carlos Afranio es_ES
dc.contributor.author Alcázar-Ortega, Manuel es_ES
dc.date.accessioned 2016-06-24T11:56:48Z
dc.date.available 2016-06-24T11:56:48Z
dc.date.issued 2015-11
dc.identifier.issn 0960-1481
dc.identifier.uri http://hdl.handle.net/10251/66437
dc.description.abstract The aim of this research is to contribute into the diffusion of biomass power systems by analyzing and testing the throat sizing influence on the operation of a gasification plant coupled with an internal combustion engine. In order to do this, the assessment of the proper operation range for some of the driving process parameters has been carried out. The analysis has been focused on such parameters as pressure drop of the fixed bed reactor, the inlet air flow, the syngas production, electrical power production and efficiency, looking for improving the performance and guaranteeing the proper system operation. Two different campaigns of tests have been carried out for figuring out the best design on the reactor. Based on this analysis, the most convenient throat diameter has been determined (in this case, around 10 cm), producing an increment in the production of syngas of about 31%. This modification has demonstrated also an increment of the electrical power produced by the gasification plant of about 40%, which means an increment in the motor generator efficiency of 35%. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Renewable Energy es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Throat size es_ES
dc.subject Downdraft gasifier es_ES
dc.subject Pressure drop es_ES
dc.subject Biomass es_ES
dc.subject Syngas es_ES
dc.subject Renewable resources es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.title Impact of the throat sizing on the operating parameters in an experimental fixed bed gasifier: Analysis, evaluation and testing es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.renene.2015.04.068
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica es_ES
dc.description.bibliographicCitation Montuori, L.; Vargas Salgado, CA.; Alcázar-Ortega, M. (2015). Impact of the throat sizing on the operating parameters in an experimental fixed bed gasifier: Analysis, evaluation and testing. Renewable Energy. 83:615-625. doi:10.1016/j.renene.2015.04.068 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.renene.2015.04.068 es_ES
dc.description.upvformatpinicio 615 es_ES
dc.description.upvformatpfin 625 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 83 es_ES
dc.relation.senia 290556 es_ES