Mostrar el registro sencillo del ítem
dc.contributor.author | Gandía-Romero, Jose Manuel | es_ES |
dc.contributor.author | Bataller Prats, Román | es_ES |
dc.contributor.author | Monzón, Pablo | es_ES |
dc.contributor.author | Campos Sánchez, Inmaculada | es_ES |
dc.contributor.author | Garcia-Breijo, Eduardo | es_ES |
dc.contributor.author | Valcuende Payá, Manuel Octavio | es_ES |
dc.contributor.author | Soto Camino, Juan | es_ES |
dc.date.accessioned | 2016-06-30T12:45:06Z | |
dc.date.available | 2016-06-30T12:45:06Z | |
dc.date.issued | 2016-01 | |
dc.identifier.issn | 0925-4005 | |
dc.identifier.uri | http://hdl.handle.net/10251/66826 | |
dc.description.abstract | In order to monitor the chloride penetration processes, a potentiometric embedded thick-film sensor was developed. This paper includes the results of research on the characterization of Cl− sensors made of Ag/AgCl resistive pastes (materials, sensitivity and detection limit, reproducibility, reversibility and response time, long-term performance and reliability in the presence of interfering agents). Theoretical expressions have been developed to describe the potentiometric response including the presence of OH− and bromide ions. The study shows that thick-film sensors are able to monitor Cl− activity as a function of the redox potential. Sensors are also capable of providing reliable and continuous real-time information on phenomena related to the progress of the chloride penetration front in concrete specimens. These sensors are a promising tool because thick-film technology allows us to obtain miniaturized, low-cost, robust and stable long-term sensors for Cl− monitoring. | es_ES |
dc.description.sponsorship | The pre-doctoral scholarship granted to Roman Bataller Prats within the program "Formacion de Personal Investigador (FPI) 2012" from Universitat Politecnica de Valencia is gratefully acknowledged. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Sensors and Actuators B: Chemical | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Potentiometric | es_ES |
dc.subject | Chloride ion | es_ES |
dc.subject | Sensor | es_ES |
dc.subject | Corrosion | es_ES |
dc.subject | Thick-film | es_ES |
dc.subject | Concrete | es_ES |
dc.subject.classification | QUIMICA INORGANICA | es_ES |
dc.subject.classification | CONSTRUCCIONES ARQUITECTONICAS | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Characterization of embeddable potentiometric thick-film sensors for monitoring chloride penetration in concrete | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.snb.2015.07.056 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Construcciones Arquitectónicas - Departament de Construccions Arquitectòniques | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Gandía-Romero, JM.; Bataller Prats, R.; Monzón, P.; Campos Sánchez, I.; Garcia-Breijo, E.; Valcuende Payá, MO.; Soto Camino, J. (2016). Characterization of embeddable potentiometric thick-film sensors for monitoring chloride penetration in concrete. Sensors and Actuators B: Chemical. 222:407-418. doi:10.1016/j.snb.2015.07.056 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.snb.2015.07.056 | es_ES |
dc.description.upvformatpinicio | 407 | es_ES |
dc.description.upvformatpfin | 418 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 222 | es_ES |
dc.relation.senia | 294011 | es_ES |
dc.contributor.funder | Universitat Politècnica de València |