- -

An electronic nose for the detection of Sarin, Soman and Tabun mimics and interfering agents

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

An electronic nose for the detection of Sarin, Soman and Tabun mimics and interfering agents

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Olguín Pinatti, Cristian Ariel es_ES
dc.contributor.author Laguarda-Miro, Nicolas es_ES
dc.contributor.author Pascual Vidal, Lluís es_ES
dc.contributor.author García Breijo, Eduardo es_ES
dc.contributor.author Martínez Mañez, Ramón es_ES
dc.contributor.author Soto Camino, Juan
dc.date.accessioned 2016-07-12T10:32:33Z
dc.date.available 2016-07-12T10:32:33Z
dc.date.issued 2014-10
dc.identifier.issn 0925-4005
dc.identifier.uri http://hdl.handle.net/10251/67458
dc.description.abstract An electronic nose system (E-nose) with metal oxide semiconductor sensors (MOS) has been designed to discriminate and quantify different chemical warfare agents (CWA) mimics. The E-nose consists of an array of commercial MOS for different gases, two sensors for temperature sensing, a sample handling system, a data acquisition system and a laptop with the data acquisition system control. With this device, discrimination studies have been carried out to detect specific CWA simulants (diethyl chlorophosphonate (DCP), diethyl cyanophosphate (DCNP), diisipropyl fluoride (DFP)), their derivatives (diethyl 1-phenylethyl phosphonate (OP-1), diethyl (2- cyanoethyl)phosphonate (OP-2), dimethyl methyl phosphonate (OP-3) and diethyl (2-oxopropyl)phosphonate (OP-4)) and some potential interfering substances (sulfuric acid, ammonia, ethanol and acetone). Principal components analyses (PCA) show that it is possible to discriminate the studied organophosphorous CWA mimics (DCP, DCNP and DFP) from the other studied derivatives and potential interfering agents. In addition, DCNP quantification studies have been done by using partial least squares (PLS) and a mathematical model has been obtained to predict DCNP concentrations in air. In this model, the coefficient of determination (R2) is 0.9567, the root mean square error of prediction (RMSEP) is 30 and the limit of detection (LOD) is 5 ppm so the model is considered valid. These results suggest that this E-nose system is capable to discriminate and quantify CWA mimics and it would be a feasible system to be used in a real scenario. es_ES
dc.description.sponsorship Financial support from the Spanish Government (MAT2009-14564-C04-02 and MAT2009-14564-C04-01), the Grant BES-2010-034031 from the FPI-MINECO Subprogram and the Spanish Government and European FEDER funds (MAT2012-38429-C04-04) are gratefully acknowledged. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Sensors and Actuators B: Chemical es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Electronic nose es_ES
dc.subject MOS es_ES
dc.subject CWA Simulants es_ES
dc.subject Discrimination es_ES
dc.subject Quantification es_ES
dc.subject.classification QUIMICA INORGANICA es_ES
dc.subject.classification INGENIERIA QUIMICA es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title An electronic nose for the detection of Sarin, Soman and Tabun mimics and interfering agents es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.snb.2014.05.060
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-02/ES/Aproximacion Al Biomimetismo Usando Lenguas Electronicas Y Narices Para La Deteccion De Explosivos Y Agentes Nerviosos/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-01/ES/Nanomateriales Hibridos Para El Desarrollo De "Puertas Moleculares" De Aplicacion En Procesos De Reconocimiento Y Terapeutica Y Para La Deteccion De Explosivos./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//BES-2010-034031/ES/BES-2010-034031/ / es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//MAT2012-38429-C04-04/ES/DESARROLLO DE NUEVOS SISTEMAS DE DETECCION Y ACCION BASADOS EN TECNOLOGIAS ELECTRONICAS Y MICROELECTRONICAS PARA SU APLICACION EN SISTEMAS DE LIBERACION Y DETECCION DE GASES/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Química - Departament de Química es_ES
dc.description.bibliographicCitation Olguín Pinatti, CA.; Laguarda-Miro, N.; Pascual Vidal, L.; García Breijo, E.; Martínez Mañez, R.; Soto Camino, J. (2014). An electronic nose for the detection of Sarin, Soman and Tabun mimics and interfering agents. Sensors and Actuators B: Chemical. 202:31-37. https://doi.org/10.1016/j.snb.2014.05.060 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.snb.2014.05.060 es_ES
dc.description.upvformatpinicio 31 es_ES
dc.description.upvformatpfin 37 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 202 es_ES
dc.relation.senia 267716 es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem