dc.description.abstract | [ES] Para realizar el diseño teórico del sistema de adquisición, previamente hubo que realizar un estudio teórico sobre los potenciales bioeléctricos generados en el cuerpo humano. En el caso que ocupa, se prestó mayor atención a aquellos potenciales de origen muscular, de los que se obtuvieron los rangos de frecuencia y tensión más comunes. Una vez conocidas las características de las señales, se comenzó el diseño teórico del sistema. Debido a que el electromiógrafo es un elemento de aplicación médica, el aislamiento del paciente con respecto a la alimentación y a los aparatos de medida fue la prioridad; para ello se utilizaron componentes con el distintivo “Medical Instrumentation” en sus respectivos datasheet, lo que los califica de aptos para el uso en este tipo de aplicaciones. | es_ES |
dc.description.abstract | [CA] Per realitzar el disseny teòric del sistema d'adquisició, prèviament va caldre realitzar un estudi teòric sobre els potencials bioelèctrics generats al cos humà. En el cas que ocupa, es va prestar més atenció a aquells potencials d'origen muscular, dels quals es van obtenir els rangs de freqüència i tensió més comuns . Una vegada conegudes les característiques de les senyals, es va començar el disseny teòric del sistema. Pel fet que l’electromiògraf és un element d'aplicació mèdica, l'aïllament del pacient pel que fa a l'alimentació i als aparells de mesura va ser la prioritat; per a això es van utilitzar components amb el distintiu "Medical Instrumentation" en els seus respectius datasheet, la qual cosa els qualifica d'aptes per a l'ús en aquest tipus d'aplicacions. | es_ES |
dc.description.abstract | [EN] To perform the theoretical design of the acquisition system, previously had to be made a theoretical study of the bioelectric potential generated in the human body. In the present case, greater attention was paid to those potential of muscular origin, of which the ranges were obtained in the more common values of frequency and voltage. Once known the characteristics of the signals, the theoretical design of the system began. Since the electromyograph is an element of medical application, the isolation of the patient respect the power supply and the measuring devices was the priority; in order to do that, were used components which were labelled with "Medical Instrumentation" in their respective datasheet, which describes them as suitable for use in such applications. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Señales bioeléctricas | es_ES |
dc.subject | Sensores | es_ES |
dc.subject | Instrumentación electrónica | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.subject.other | Grado en Ingeniería en Tecnologías Industriales-Grau en Enginyeria en Tecnologies Industrials | es_ES |
dc.title | Diseño y desarrollo de un sistema de registro de la actividad muscular | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Guerrero López, JC. (2016). Diseño y desarrollo de un sistema de registro de la actividad muscular. http://hdl.handle.net/10251/70106. | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\29475 | es_ES |