Mostrar el registro sencillo del ítem
dc.contributor.author | Yang, Chanseung | es_ES |
dc.contributor.author | Kang, Tae-June | es_ES |
dc.contributor.author | Hyun, Doosoo | es_ES |
dc.contributor.author | Lee, Sang Bin | es_ES |
dc.contributor.author | Antonino Daviu, José Alfonso | es_ES |
dc.contributor.author | Pons Llinares, Joan | es_ES |
dc.date.accessioned | 2016-10-03T11:50:12Z | |
dc.date.available | 2016-10-03T11:50:12Z | |
dc.date.issued | 2014-08 | |
dc.identifier.issn | 0093-9994 | |
dc.identifier.uri | http://hdl.handle.net/10251/70911 | |
dc.description | © 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.” Upon publication, authors are asked to include either a link to the abstract of the published article in IEEE Xplore®, or the article’s Digital Object Identifier (DOI). | es_ES |
dc.description.abstract | Axial cooling air ducts in the rotor of large induction motors are known to produce magnetic asymmetry and can cause steady-state current or vibration spectrum analysis based fault detection techniques to fail. If the number of axial air ducts and that of poles are identical, frequency components that overlap with that of rotor faults can be produced for healthy motors. False positive rotor fault indication due to axial ducts is a common problem in the field that results in unnecessary maintenance cost. However, there is currently no known test method available for distinguishing rotor faults and false indications due to axial ducts other than offline rotor inspection or testing. Considering that there is no magnetic asymmetry under high slip conditions due to limited flux penetration into the rotor yoke, the detection of broken bars under the start-up transient is investigated in this paper. A wavelet-based detection method is proposed and verified on custom-built lab motors and 6.6-kV motors misdiagnosed with broken bars via steady-state spectrum analysis. It is shown that the proposed method provides the reliable detection of broken bars under the start-up transient independent of axial duct influence. | es_ES |
dc.description.sponsorship | This work was supported in part by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (NRF-2013R1A1A2010370) and in part by the Human Resources Development Program (20134030200340) of the Korea Institute of Energy Technology Evaluation and Planning Grant funded by the Korea Government Ministry of Trade, Industry, and Energy. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | es_ES |
dc.relation.ispartof | IEEE Transactions on Industry Applications | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | AC machines | es_ES |
dc.subject | fault diagnosis | es_ES |
dc.subject | induction motors | es_ES |
dc.subject | rotor fault | es_ES |
dc.subject | start-up analysis | es_ES |
dc.subject.classification | INGENIERIA ELECTRICA | es_ES |
dc.title | Reliable Detection of Induction Motor Rotor Faults Under the Rotor Axial Air Duct Influence | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1109/TIA.2013.2297448 | |
dc.relation.projectID | info:eu-repo/grantAgreement/NRF//2013R1A1A2010370/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/KETEP//20134030200340/ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica | es_ES |
dc.description.bibliographicCitation | Yang, C.; Kang, T.; Hyun, D.; Lee, SB.; Antonino Daviu, JA.; Pons Llinares, J. (2014). Reliable Detection of Induction Motor Rotor Faults Under the Rotor Axial Air Duct Influence. IEEE Transactions on Industry Applications. 50(4):2493-2502. https://doi.org/10.1109/TIA.2013.2297448 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1109/TIA.2013.2297448 | es_ES |
dc.description.upvformatpinicio | 2493 | es_ES |
dc.description.upvformatpfin | 2502 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 50 | es_ES |
dc.description.issue | 4 | es_ES |
dc.relation.senia | 271788 | es_ES |
dc.identifier.eissn | 1939-9367 | |
dc.contributor.funder | Korea Institute of Energy Technology Evaluation and Planning | es_ES |
dc.contributor.funder | National Research Foundation of Korea | es_ES |