dc.description.abstract | Protein adsorption on biomedical CoCrMo alloys plays a crucial role in biocompatibility, corrosion and wear properties of implants. So far, protein adsorption was studied only on passive CoCrMo alloys above the open circuit potential. In this work the adsorption of Bovine Serum Albumin (BSA) under cathodic conditions was investigated using a combination of Electrochemical Quartz Cristal Microbalance (EQCM) and X-Ray Photoelectron Spectroscopy (XPS) surface analysis. Results show that cathodic polarization yields larger BSA adsorption than what reported at passive potentials. The involved adsorption mechanism is related to the electrochemical controlled reduction of BSA. | es_ES |
dc.description.sponsorship | Authors would like to thank you the Spanish Government "Ministry of Education, Culture and Sport" for the financial support of A. Igual Munoz through the grant "Salvador de Maradriaga" during her stay at the EPFL (Switzerland). They also thank N. Xanthopoulos for his assistance with the XPS measurements and P. Mettraux for the PVD deposits. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation | Spanish Government "Ministry of Education, Culture and Sport" | es_ES |
dc.relation.ispartof | Electrochimica Acta | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Electrochemical Quartz Crystal Microbalance | es_ES |
dc.subject | X-Ray Photoelectron Surface | es_ES |
dc.subject | Bovine Serum Albumin | es_ES |
dc.subject | Adsorption | es_ES |
dc.subject | CoCrMo alloy | es_ES |
dc.subject | Passivity | es_ES |
dc.subject.classification | INGENIERIA QUIMICA | es_ES |
dc.title | Electrochemical Quartz Crystal Microbalance and X-Ray Photoelectron Spectroscopy study of cathodic reactions in Bovine Serum Albumin containing solutions on a Physical Vapour Deposition-CoCrMo biomedical alloy | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.electacta.2015.08.017 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear | es_ES |
dc.description.bibliographicCitation | Igual Muñoz, AN.; Mischler, S. (2015). Electrochemical Quartz Crystal Microbalance and X-Ray Photoelectron Spectroscopy study of cathodic reactions in Bovine Serum Albumin containing solutions on a Physical Vapour Deposition-CoCrMo biomedical alloy. Electrochimica Acta. 180:96-103. doi:10.1016/j.electacta.2015.08.017 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.electacta.2015.08.017 | es_ES |
dc.description.upvformatpinicio | 96 | es_ES |
dc.description.upvformatpfin | 103 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 180 | es_ES |
dc.relation.senia | 304173 | es_ES |
dc.identifier.eissn | 1873-3859 | |
dc.contributor.funder | Ministerio de Educación, Cultura y Deporte | es_ES |