dc.description.abstract | [EN] Heat pumps lose much efficiency when they are working in very cold weather conditions or when they are dedicated to the production of water at very high temperatures. There are appearing some solutions on the market that allow to extend the working conditions of this type of equipment as well as increase efficiency in extreme conditions. This project aims to design a heat pump ready to work in these extreme conditions and the development of a comparative analysis between the efficiencies and capacities achieved with the designed systemcompared with a conventional system. | es_ES |
dc.description.abstract | [ES] Las bombas de calor tienden a perder mucha eficiencia cuando trabajan en condiciones climaticas muy frias o cuando se dedican a producir agua a temperaturas muy altas. Para ello en los ultimos años se estan implementando algunas soluciones en el mercado que permiten extender las condiciones de uso de este tipo de equipos asi como incrementar su eficiencia en condiciones extremas. En este proyecto se pretende diseñar una bomba de calor preparada para trabajar en este tipo de condiciones extremas mostrando ademas un analisis comparativo entre las eficiencias y capacidades conseguidas con este equipo en relacion con un sistema convencional. | es_ES |
dc.format.extent | 113 | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Heat pump | es_ES |
dc.subject | Efficiency | es_ES |
dc.subject | Sanitary hot water | es_ES |
dc.subject | Bomba de calor | es_ES |
dc.subject | Eficiencia | es_ES |
dc.subject | Agua caliente sanitaria | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.other | Grado en Ingeniería Mecánica-Grau en Enginyeria Mecànica | es_ES |
dc.title | Instalación de climatización para la casa de la música de Antella | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | García Dávila, D. (2016). Instalación de climatización para la casa de la música de Antella. Universitat Politècnica de València. http://hdl.handle.net/10251/73190 | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\14951 | es_ES |