Mostrar el registro sencillo del ítem
dc.contributor.author | Calvo, David | es_ES |
dc.contributor.author | Atienza, Felipe | es_ES |
dc.contributor.author | Jalife, José | es_ES |
dc.contributor.author | Martínez Alzamora, Mª Nieves | es_ES |
dc.contributor.author | Bravo, Loreto | es_ES |
dc.contributor.author | Almendral Garrote, Jesús | es_ES |
dc.contributor.author | González-Torrecilla, Esteban | es_ES |
dc.contributor.author | Arenal, Ángel | es_ES |
dc.contributor.author | Bermejo, Javier | es_ES |
dc.contributor.author | Fernández-Avilés, Francisco | es_ES |
dc.contributor.author | Berenfeld, Omer | es_ES |
dc.date.accessioned | 2016-12-12T17:11:23Z | |
dc.date.available | 2016-12-12T17:11:23Z | |
dc.date.issued | 2012-11 | |
dc.identifier.issn | 1099-5129 | |
dc.identifier.uri | http://hdl.handle.net/10251/75131 | |
dc.description.abstract | Aims Research on paroxysmal atrial fibrillation (AF) assumes that fibrillation induced by rapid pacing adequately reproduces spontaneously occurring paroxysmal AF in humans. We aimed to compare the spectral properties of spontaneous vs. induced AF episodes in paroxysmal AF patients. Methods and results Eighty-five paroxysmal AF patients arriving in sinus rhythm to the electrophysiology laboratory were evaluated prior to ablation. Atrial fibrillation was induced by rapid pacing from the pulmonary vein-left atrial junctions (PV-LAJ), the coronary sinus (CS), or the high right atrium (HRA). Simultaneous recordings were obtained using multipolar catheters. Off-line power spectral analysis of 5 s bipolar electrograms was used to determine dominant frequency (DF) at recording sites with regularity index 0.2. Sixty-eight episodes were analysed for DF. Comparisons were made between spontaneous (n = 23) and induced (n = 45) AF episodes at each recording site. No significant differences were observed between spontaneous and induced AF episodes in HRA (5.18 +/- 0.69 vs. 5.06 +/- 0.91 Hz; P = 0.64), CS (5.27 +/- 0.69 vs. 5.36 +/- 0.76 Hz; P = 0.69), or LA (5.72 +/- 0.88 vs. 5.64 +/- 0.75 Hz; P = 0.7) regardless of pacing site. Consistent with these results, paired analysis in seven patients with both spontaneous and induced AF episodes, showed no regional DFs differences. Moreover, a left-to-right DF gradient was also present in both spontaneous (PV-LAJ 5.71 +/- 0.81 vs. HRA 5.18 +/- 0.69 Hz; P = 0.005) and induced (PV-LAJ 5.62 +/- 0.72 vs. HRA 5.07 +/- 0.91 Hz; P = 0.002) AF episodes, with no differences between them (P = not specific). Conclusion In patients with paroxysmal AF, high-rate pacing-induced AF adequately mimics spontaneously initiated AF, regardless of induction site. | es_ES |
dc.description.sponsorship | This study was supported in part by grants from the Spanish Society of Cardiology (D. C. and F. A.); the Ministerio de Economia y Competitividad, Red RECAVA (F. A., J.A., E. G. T., A. A., J.B., and F. F. A.); the Centro Nacional de Investigaciones Cardiovasculares (proyecto CNIC-13) to (F. A., J.A., E. G. T., O.B., and J.J.); NIH P01 HL087226 and the Leducq Foundation (J.J. and O.B.); and the Gelman and the Coulter awards from the University of Michigan (O.B.). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Oxford University Press (OUP) | es_ES |
dc.relation.ispartof | EP-Europace | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Atrial fibrillation | es_ES |
dc.subject | Pulmonary veins | es_ES |
dc.subject | Dominant frequency | es_ES |
dc.subject | Inducibility | es_ES |
dc.subject | Left atrial diameter | es_ES |
dc.subject.classification | ESTADISTICA E INVESTIGACION OPERATIVA | es_ES |
dc.title | High-rate pacing-induced atrial fibrillation effectively reveals properties of spontaneously occurring paroxysmal atrial fibrillation in humans | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1093/europace/eus180 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MSC//RD06%2F0014/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/NIH//7P01HL087226-02/US/P3: Biophysical Mechanisms in two Arhythmogenic Diseases/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Estadística e Investigación Operativa Aplicadas y Calidad - Departament d'Estadística i Investigació Operativa Aplicades i Qualitat | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | Calvo, D.; Atienza, F.; Jalife, J.; Martínez Alzamora, MN.; Bravo, L.; Almendral Garrote, J.; González-Torrecilla, E.... (2012). High-rate pacing-induced atrial fibrillation effectively reveals properties of spontaneously occurring paroxysmal atrial fibrillation in humans. EP-Europace. 14(11):1560-1566. https://doi.org/10.1093/europace/eus180 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1093/europace/eus180 | es_ES |
dc.description.upvformatpinicio | 1560 | es_ES |
dc.description.upvformatpfin | 1566 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 14 | es_ES |
dc.description.issue | 11 | es_ES |
dc.relation.senia | 230056 | es_ES |
dc.identifier.pmid | 22696516 | es_ES |
dc.identifier.pmcid | PMC3697800 | es_ES |
dc.contributor.funder | University of Michigan | es_ES |
dc.contributor.funder | National Institutes of Health, EEUU | es_ES |
dc.contributor.funder | Ministerio de Sanidad y Consumo | es_ES |
dc.contributor.funder | Sociedad Española de Cardiología | es_ES |
dc.contributor.funder | Leducq Foundation | es_ES |
dc.contributor.funder | Centro Nacional de Investigaciones Cardiovasculares | es_ES |