dc.contributor.advisor | Trénor Gomis, Beatriz Ana | es_ES |
dc.contributor.advisor | Prats Boluda, Gema | es_ES |
dc.contributor.author | Terrés Haro, José Manuel | es_ES |
dc.date.accessioned | 2016-12-22T10:10:42Z | |
dc.date.available | 2016-12-22T10:10:42Z | |
dc.date.created | 2016-07-14 | |
dc.date.issued | 2016-12-22 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/75625 | |
dc.description.abstract | Nowadays the study and acquisition of bioelectric signalshas wide applicability in the field of medical diagnosis. In the course of Bioelectronic of the Degree in Electronic and Automation Engineering, the students design and develop in a PC board conditioning systems for different bioelectric signals, such as electrocardiogram, electromyogram, electrooculogram and electrogastrogram. It has identified the need for a modular and configurable system that allows students to check their designs. Specifically in this work the student will design, simulate and implement PCB the different stages of the mentioned conditioning system. The system should be versatile, facilitating the connection and disconnection of each stage, and offering the possibility of changing the incomes and cutoff frequencies of the stages. It should be also programmed an user interface into the LabVIEW environment for the acquisition, display and storage of the output signals. The student will write a user manual. | es_ES |
dc.description.abstract | El estudio y captación de las señales bioeléctricas tiene hoy en día una gran aplicabilidad en el campo del diagnóstico médico. En la asignatura de Bioelectrónica de la titulación de Grado en Ingeniería Electrónica y Automática, los alumnos diseñan y montan en placa de prototipado diferentes sistemas de acondicionamiento de señales bioeléctricas, como el electrocardiograma, el electromiograma, el electrooculograma y el electrogastrograma. Se ha detectado la necesidad de un sistema modular y configurable que permita a los alumnos la comprobación de sus diseños. Concretamente en el presente trabajo el alumno diseñará, simulará e implementará en PCB las diferentes etapas que constituyen los sistemas de acondicionamiento mencionados. El sistema será versátil facilitando la conexión y desconexión de cada etapa, y ofreciendo la posibilidad de modificar ganancias y frecuencias de corte de las etapas. Asimismo, se programará en el entorno labview la adquisición, visualización y almacenamiento de la señal de salida. El alumno redactará un manual de usuario. | es_ES |
dc.format.extent | 182 | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Electrocardiogram | es_ES |
dc.subject | Electromyogram | es_ES |
dc.subject | Electrooculógram | es_ES |
dc.subject | Electroenterogram | es_ES |
dc.subject | Acquisition system | es_ES |
dc.subject | Measurement and visualization | es_ES |
dc.subject | Electromiógrafo | es_ES |
dc.subject | Electrocardiógrafo | es_ES |
dc.subject | Electrooculógrafo | es_ES |
dc.subject | Sistema de adquisición | es_ES |
dc.subject | Electroenterógrafo | es_ES |
dc.subject | Medida y visualización | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.subject.other | Grado en Ingeniería Electrónica Industrial y Automática-Grau en Enginyeria Electrònica Industrial i Automàtica | es_ES |
dc.title | Diseño e implementación de un sistema modular y configurable para la captación de distintas señales bioeléctricas | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | Terrés Haro, JM. (2016). Diseño e implementación de un sistema modular y configurable para la captación de distintas señales bioeléctricas. Universitat Politècnica de València. http://hdl.handle.net/10251/75625 | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\35460 | es_ES |