dc.identifier.uri http://hdl.handle.net/10251/76340
dc.description.abstract This paper presents a study of the effects of axial and rotational restraints on the fire response of concrete filled tubular (CFT) columns. The fiber model presented by the authors in a previous paper Ibañez et al. (2013) is employed to simulate the fire behavior of CFT columns within non-sway frames. Parametric studies are performed to analyze the influence of the different factors affecting the problem. Consequently, the opposite effects that the restraining frame has on the fire response of CFT columns are corroborated. On one hand, the restrained thermal elongation induces restraining forceswhich negatively affects the column. However, a beneficial effect is produced by the rotational restraintwhich positively modifies the boundary conditions of the heated column. Besides, another favorable effect comes from the gradual redistribution of the internal forces as the heated column loses its mechanical capacity, resulting in higher FRR. In a second step, current provisions given by Eurocode 4 Part 1.2 (EC4) are analyzed together with those given in the UK National Annex to Eurocode 4. Finally, these values are also used in the assessment of the simple calculation model presented by the authors in a previous paper Ibañez et al. (2015) and subsequently a proposal is made obtaining reasonably accurate but slightly safe results since the guidelines of CEN-Horizontal Group Fire were followed. As a result, the fire effective length value of 0.5 L given by EC4 is found to lead to unsafe results, being more appropriate to adopt the value of 0.7 L suggested in the UK National Annex. es_ES
dc.description.sponsorship The authors would like to express their sincere gratitude to both the Spanish "Ministerio de Ciencia e Innovacion" and to the European Community through the FEDER funds for the help provided to finance the Project BIA2012-33144. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Journal of Constructional Steel Research es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Concrete filled tubular column es_ES
dc.subject Axial and rotational restraints es_ES
dc.subject Simple calculation method es_ES
dc.subject Effective length es_ES
dc.subject Non-sway frames es_ES
dc.subject Eurocode 4 es_ES
dc.subject.classification MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.title Effects of axial and rotational restraints on concrete-filled tubular columns under fire es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.jcsr.2016.06.010
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//BIA2012-33144/ES/CARACTERIZACION NUMERICA Y EXPERIMENTAL DE PILARES TUBULARES DE ACERO RELLENOS DE HORMIGON CON DOBLE-TUBO YHORMIGON DE ULTRA-ALTA RESISTENCIA/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ciencia y Tecnología del Hormigón - Institut de Ciència i Tecnologia del Formigó es_ES
dc.description.bibliographicCitation Ibáñez Usach, C.; Romero, ML.; Hospitaler Pérez, A. (2016). Effects of axial and rotational restraints on concrete-filled tubular columns under fire. Journal of Constructional Steel Research. 125:114-127. https://doi.org/10.1016/j.jcsr.2016.06.010 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi. org/10.1016/j.jcsr.2016.06.010 es_ES
dc.description.upvformatpinicio 114 es_ES
dc.description.upvformatpfin 127 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 125 es_ES
dc.relation.senia 314618 es_ES
dc.identifier.eissn 1873-5983
dc.contributor.funder Ministerio de Economía y Competitividad es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem