- -

Monoclonal antibody-based flow-through immunosensor for analysis of carbaryl

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Monoclonal antibody-based flow-through immunosensor for analysis of carbaryl

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author González Martínez, Miguel Ángel es_ES
dc.contributor.author Morais, Sergi es_ES
dc.contributor.author Puchades, Rosa es_ES
dc.contributor.author Maquieira Catala, Ángel es_ES
dc.contributor.author Abad Fuentes, Antonio es_ES
dc.contributor.author Montoya Baides, Ángel es_ES
dc.date.accessioned 2017-01-23T13:46:06Z
dc.date.issued 1997-07-15
dc.identifier.issn 0003-2700
dc.identifier.uri http://hdl.handle.net/10251/77231
dc.description.abstract [EN] Immunosensor systems have been developed for the rapid and sensitive determination of pesticides, using the insecticide carbaryl as a model analyte. The systems are based on the principle of heterogeneous competitive enzyme immunoassay and used mouse monoclonal anti-carbaryl antibodies either in solution (indirect format) or immobilized (direct format). In both formats, enzyme label (horseradish peroxidase, HRP) and fluorometric detection were employed. In the direct format, antibodies were immobilized on a hydrazide-derivatized agarose gel, and 6-[((1-naphthyloxy)carbonyl)amino]hexanoic acid (CNH hapten) conjugated to HRP was used as the enzyme tracer. The limit of detection was 26 ng L-1 (11 min/assay), and the useful life of the sensor was 60−70 cycles. In the indirect format, CNH conjugated to bovine serum albumin was immobilized on an N-hydroxysuccinimide-derivatized agarose gel, and a rabbit anti-mouse antibody labeled with HRP was used as a secondary immunoreagent. The limit of detection was 284 ng L-1 (17 min/assay), and the useful life of the sensor was 160−200 cycles. The developed methods were applied to the analysis of commercial drinking water and apple juice spiked with carbaryl. Interassay RSD ranged from 9 to 39% in the direct format and from 4 to 28% in the indirect format. Recoveries were between 62 and 109% in the direct format and between 78 and 124% in the indirect format. The results were compared with those obtained by enzyme-linked immunosorbent assay as reference method and indicated the suitability of the immunosensor for quality control in water and food analysis es_ES
dc.description.sponsorship This project was supported by the CICYT project AMB 96-1079 and the DGCYT project PB 95-0740. M.A.G.-M. acknowledges a grant from the Fundacio´n Caja Madrid to carry out Ph.D. studies.
dc.language Inglés es_ES
dc.publisher American Chemical Society es_ES
dc.relation.ispartof Analytical Chemistry es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Immobilized enzyme reactors es_ES
dc.subject Pesticides es_ES
dc.subject.classification QUIMICA ANALITICA es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Monoclonal antibody-based flow-through immunosensor for analysis of carbaryl es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.1021/ac961068t
dc.relation.projectID info:eu-repo/grantAgreement/MECD//AMB96-1079/ES/VIGILANCIA DE LA CONTAMINACIÓN POR PLAGUICIDAS Y SUS METABOLITOS MEDIANTE INMUNOSENSORES. PUESTA A PUNTO Y VALIDACIÓN EN UN SISTEMA DE ABASTECIMIENTO DE AGUAS POTABLES/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MEC//PB95-0740/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural - Escola Tècnica Superior d'Enginyeria Agronòmica i del Medi Natural es_ES
dc.description.bibliographicCitation González Martínez, MÁ.; Morais, S.; Puchades, R.; Maquieira Catala, Á.; Abad Fuentes, A.; Montoya Baides, Á. (1997). Monoclonal antibody-based flow-through immunosensor for analysis of carbaryl. Analytical Chemistry. 69(14):2812-2818. https://doi.org/10.1021/ac961068t es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://dx.doi.org/10.1021/ac961068t es_ES
dc.description.upvformatpinicio 2812 es_ES
dc.description.upvformatpfin 2818 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 69 es_ES
dc.description.issue 14 es_ES
dc.relation.senia 15467 es_ES
dc.contributor.funder Ministerio de Educación, Cultura y Deporte es_ES
dc.contributor.funder Ministerio de Educación y Ciencia es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem