In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Herreros, Jesús es_ES
dc.contributor.author Ubilla, Matías es_ES
dc.contributor.author Berjano Zanón, Enrique es_ES
dc.contributor.author Vila-Nuñez, Juan E. es_ES
dc.contributor.author Páramo, José A. es_ES
dc.contributor.author Sola, Josu es_ES
dc.contributor.author Mercé, Salvador es_ES
dc.date.accessioned 2017-03-27T14:47:47Z
dc.date.available 2017-03-27T14:47:47Z
dc.date.issued 2010-02
dc.identifier.issn 0160-564X
dc.identifier.uri http://hdl.handle.net/10251/79116
dc.description.abstract The aim of this study was to assess platelet dysfunction and damage to organs after extracorporeal circulation using a pump based on a new method that adds a pulsatile flow to the continuous flow provided by a centrifugal pump. The continuous component of the total flow (2–3 L/min) is created by a Bio-Pump centrifugal pump, while the pulsatile component is created by the pulsating of an inner membrane pneumatically controlled by an intraaortic counterpulsation balloon console (systolic volume of 37.5 mL in an asynchronous way with a frequency of 60 bpm). Six pigs were subjected to a partial cardiopulmonary bypass lasting 180 min and were sacrificed 60 min after extracorporeal circulation was suspended. The hematological study included the measurement of hematocrit, hemoglobin, leukocytes, and platelet function. The new pump did not significantly alter either platelet count or platelet function. In contrast, hematocrit and hemoglobin were significantly reduced during extracorporeal circulation (approximately 5% P = 0.011, and 2 g/dL P = 0.01, respectively). The leukocyte count during extracorporeal circulation showed a tendency to decrease, but this was not significant. In general, the short-term use of the new pump (4 h) did not cause any serious morphological damage to the heart, lung, kidney, or liver. The results suggest that the hemodynamic performance of the new pump is similar to a conventional centrifugal pump and could therefore be appropriate for use in extracorporeal circulation. es_ES
dc.language Inglés es_ES
dc.publisher Wiley es_ES
dc.relation.ispartof Artificial Organs es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Centrifugal pump es_ES
dc.subject Extracorporeal circulation es_ES
dc.subject Organ injury es_ES
dc.subject Platelet count es_ES
dc.subject Pulsatile flow es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1111/j.1525-1594.2009.00769.x
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Herreros, J.; Ubilla, M.; Berjano Zanón, E.; Vila-Nuñez, JE.; Páramo, JA.; Sola, J.; Mercé, S. (2010). In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump. Artificial Organs. 34(2):140-146. doi:10.1111/j.1525-1594.2009.00769.x es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1111/j.1525-1594.2009.00769.x es_ES
dc.description.upvformatpinicio 140 es_ES
dc.description.upvformatpfin 146 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 34 es_ES
dc.description.issue 2 es_ES
dc.relation.senia 39636 es_ES
dc.identifier.eissn 1525-1594


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem