- -

Attenuation correction without transmission scan for the MAMMI breast PET

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Attenuation correction without transmission scan for the MAMMI breast PET

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Soriano Asensi, Antonio es_ES
dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Orero Palomares, Abel es_ES
dc.contributor.author Moliner Martínez, Laura es_ES
dc.contributor.author Carles Fariña, Montserrat es_ES
dc.contributor.author Sánchez Martínez, Filomeno es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.contributor.author Correcher Salvador, Carlos es_ES
dc.contributor.author Carrilero Lopez, Vicente es_ES
dc.contributor.author Seimetz, Michael es_ES
dc.date.accessioned 2017-04-05T10:12:29Z
dc.date.available 2017-04-05T10:12:29Z
dc.date.issued 2011-08-21
dc.identifier.issn 0168-9002
dc.identifier.uri http://hdl.handle.net/10251/79480
dc.description.abstract [EN] Whole-body Positron Emission Tomography (PET) scanners are required in order to span large Fields of View (FOV). Therefore, reaching the sensitivity and spatial resolution required for early stage breast tumor detection is not straightforward. MAMMI is a dedicated breast PET scanner with a ring geometry designed to provide PET images with a spatial resolution as high as 1.5 mm, being able to detect small breast tumors ðo1 cmÞ. The patient lays down in prone position during the scan, thus making possible to image the whole breast, up to regions close to the base of the pectoral without the requirement of breast compression. Attenuation correction (AC) for PET data improves the image quality and the quantitative accuracy of radioactivity distribution determination. In dedicated, high resolution breast cancer scanners, this correction would enhance the proper diagnosis in early disease stages. In whole-body PET scanners, AC is usually taken into account with the use of transmission scans, either by external radioactive rod sources or by Computed Tomography (CT). This considerably increases the radiation dose administered to the patient and time needed for the exploration. In this work we propose a method for breast shape identification by means of PET image segmentation. The breast shape identification will be used for the determination of the AC. For the case of a specific breast PET scanner the procedure we propose should provide AC similar to that obtained by transmission scans as we take advantage of the breast anatomical simplicity. Experimental validation of the proposed approach with a dedicated breast PET prototype is also presented. The main advantage of this method is an important dose reduction since the transmission scan is not required. es_ES
dc.description.sponsorship This study has been partially funded by the European Commission under the project "MAMmography with Molecular Imaging MAMMI, FP6-2005-LIFESCIHEALTH-7".
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Breast PET es_ES
dc.subject Attenuation correction es_ES
dc.title Attenuation correction without transmission scan for the MAMMI breast PET es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.nima.2010.12.138
dc.relation.projectID info:eu-repo/grantAgreement/EC/FP6/LIFESCIHEALTH-7/37555/EU/Mammography with molecular imaging/MAMMI/
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.description.bibliographicCitation Soriano Asensi, A.; González Martínez, AJ.; Orero Palomares, A.; Moliner Martínez, L.; Carles Fariña, M.; Sánchez Martínez, F.; Benlloch Baviera, JM.... (2011). Attenuation correction without transmission scan for the MAMMI breast PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 648:S75-S78. doi:10.1016/j.nima.2010.12.138 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.nima.2010.12.138 es_ES
dc.description.upvformatpinicio S75 es_ES
dc.description.upvformatpfin S78 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 648 es_ES
dc.relation.senia 211765 es_ES
dc.contributor.funder European Commission


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem