Mostrar el registro sencillo del ítem
dc.contributor.author | Aguilar, Albert | es_ES |
dc.contributor.author | Garcia-Olcina, Raimundo | es_ES |
dc.contributor.author | Martinez, Pedro A. | es_ES |
dc.contributor.author | Martos, Julio | es_ES |
dc.contributor.author | Soret, Jesús | es_ES |
dc.contributor.author | Torres-Pais, Jose | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Sánchez Martínez, Filomeno | es_ES |
dc.date.accessioned | 2017-04-05T12:25:12Z | |
dc.date.available | 2017-04-05T12:25:12Z | |
dc.date.issued | 2014-01-11 | |
dc.identifier.issn | 0168-9002 | |
dc.identifier.uri | http://hdl.handle.net/10251/79497 | |
dc.description.abstract | Coincidence time measurements with SiPMs have shown to be suitable for PET/MR systems. The present study is based on 3 x 3 mm(2) SiPMs, LSO crystals and a conditioning signal electronic circuit. A Constant Fraction Discriminator (CFD) is used to digitalize the signals and a TDC FPGA-implemented is employed for fine time measurements. TDC capability allows processing the arrival of multiple events simultaneously, measuring times under 100 ps. The complete set-up for time measurements results on a resolution of 892 +/- 41 ps for a pair of detectors. The details of such implementation are exposed and the trade-offs of each configuration are discussed. (C) 2013 Elsevier By, All rights reserved, | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Time of flight | es_ES |
dc.subject | Silicon photomultipliers | es_ES |
dc.subject | Time-to-digital converter | es_ES |
dc.subject | Field Programable Gate Array | es_ES |
dc.subject | Positron emission tomography and magnetic resonance | es_ES |
dc.title | Time of flight measurements based on FPGA and SiPMs for PET MR | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.nima.2013.09.008 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto de Biología Molecular y Celular de Plantas - Institut Universitari Mixt de Biologia Molecular i Cel·lular de Plantes | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.description.bibliographicCitation | Aguilar, A.; Garcia-Olcina, R.; Martinez, PA.; Martos, J.; Soret, J.; Torres-Pais, J.; Benlloch Baviera, JM.... (2014). Time of flight measurements based on FPGA and SiPMs for PET MR. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 734:127-131. doi:10.1016/j.nima.2013.09.008 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.nima.2013.09.008 | es_ES |
dc.description.upvformatpinicio | 127 | es_ES |
dc.description.upvformatpfin | 131 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 734 | es_ES |
dc.relation.senia | 258706 | es_ES |