Ardid Ramírez, M.; Camarena Femenia, F.; Felis-Enguix, I.; Herrero Debón, A.; Llorens Alvarez, CD.; Martínez Mora, JA.; Saldaña-Coscollar, M. (2016). A compact array calibrator to study the feasibility of acoustic neutrino detection. EPJ Web of Conferences. 116(03001):1-4. https://doi.org/10.1051/epjconf/201611603001
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/79572
Title:
|
A compact array calibrator to study the feasibility of acoustic neutrino detection
|
Author:
|
Ardid Ramírez, Miguel
Camarena Femenia, Francisco
Felis-Enguix, Iván
Herrero Debón, Alicia
Llorens Alvarez, Carlos David
Martínez Mora, Juan Antonio
Saldaña-Coscollar, María
|
UPV Unit:
|
Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres
Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia
|
Issued date:
|
|
Abstract:
|
[EN] Underwater acoustic detection of ultra-high-energy neutrinos was proposed already in 1950s: when a neutrino interacts with a nucleus in water, the resulting particle cascade produces a pressure pulse that has a bipolar ...[+]
[EN] Underwater acoustic detection of ultra-high-energy neutrinos was proposed already in 1950s: when a neutrino interacts with a nucleus in water, the resulting particle cascade produces a pressure pulse that has a bipolar temporal structure and propagates within a flat disk-like volume. A telescope that consists of thousands of acoustic sensors deployed in the deep sea can monitor hundreds of cubic kilometres of water looking for these signals and discriminating them from acoustic noise. To study the feasibility of the technique it is critical to have a calibrator able to mimic the neutrino signature that can be operated from a vessel. Due to the axial-symmetry of the signal, their very directive short bipolar shape and the constraints of operating at sea, the development of such a calibrator is very challenging. Once the possibility of using the acoustic parametric technique for this aim was validated with the first compact array calibrator prototype, in this paper we describe the new design for such a calibrator composed of an array of piezo ceramic tube transducers emitting in axial direction.
[-]
|
Subjects:
|
Array acoustic
,
Acoustic neutrino detection
,
UHE particle
|
Copyrigths:
|
Reconocimiento (by)
|
ISBN:
|
978-2-7598-2016-0
|
Source:
|
EPJ Web of Conferences. (issn:
2100-014X
)
|
DOI:
|
10.1051/epjconf/201611603001
|
Publisher:
|
EDP Sciences
|
Publisher version:
|
http://dx.doi.org/10.1051/epjconf/201611603001
|
Conference name:
|
7th Biannual Very Large Volume Neutrino Telescope Workshop (VLVnT)
|
Conference place:
|
Roma, Italy
|
Conference date:
|
September 14-16, 2015
|
Project ID:
|
info:eu-repo/grantAgreement/MINECO//FPA2012-37528-C02-02/ES/PARTICIPACION DEL IGIC EN ANTARES Y KM3NET/
info:eu-repo/grantAgreement/MICINN//CSD2009-00064/ES/Método de Multimensajeros para la Detección de la Materia Oscura/
info:eu-repo/grantAgreement/GVA//ACOMP%2F2015%2F175/
info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F079/ES/Telescopios de Neutrinos en el Mediterráneo/
|
Thanks:
|
We acknowledge the financial support of the Spanish Ministerio de Economía y Competitividad, Grants
FPA2012-37528-C02-02, and Consolider MultiDark CSD2009-00064, of the Generalitat Valenciana, Grants
ACOMP/2015/175 ...[+]
We acknowledge the financial support of the Spanish Ministerio de Economía y Competitividad, Grants
FPA2012-37528-C02-02, and Consolider MultiDark CSD2009-00064, of the Generalitat Valenciana, Grants
ACOMP/2015/175 PrometeoII/2014/079 and of the European FEDER funds.
[-]
|
Type:
|
Artículo
Comunicación en congreso
|