Experimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sources

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Experimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sources

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Molés-Ribera, Francisco es_ES
dc.contributor.author Navarro Esbrí, Joaquín es_ES
dc.contributor.author Peris-Pérez, Bernardo es_ES
dc.contributor.author Mota-Babiloni, Adrián es_ES
dc.date.accessioned 2017-05-23T12:33:22Z
dc.date.available 2017-05-23T12:33:22Z
dc.date.issued 2016-04-05
dc.identifier.issn 1359-4311
dc.identifier.uri http://hdl.handle.net/10251/81657
dc.description.abstract [EN] In this work an experimental evaluation of the working fluid HCFO-1233zd-E as HFC-245fa replacement in ORC systems for low temperature heat sources has been conducted. A fully monitored ORC module has been used to test both working fluids at different operating conditions. Due to the different densities of the working fluids, the mass flow rate for HCFO-1233zd-E is approximately 20% lower than for HFC-245fa. This causes thermal and electrical powers to be lower for HCF0-1233zd-E than for HFC245fa. However, net electrical efficiency is similar for both working fluids, ranging from 5% to 9.7% in the tested operating conditions. Regarding the expander performance, various performance indicators are addressed. The expander isentropic performance has a maximum value of 75%, with higher values for HCFO-1233zd-E than for HFC-245fa. The overall efficiency of the expander, similar for both working fluids, ranges from 44% to 57% in the experimental test range. (C) 2016 Elsevier Ltd. All rights reserved. es_ES
dc.description.sponsorship The authors thankfully acknowledge the cooperation of Rank (R) for its support in this project. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Applied Thermal Engineering es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Low GWP fluids es_ES
dc.subject HFC-245fa es_ES
dc.subject Organic Rankine Cycle es_ES
dc.subject Low temperature heat sources es_ES
dc.subject Experimental evaluation es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.title Experimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sources es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.applthermaleng.2016.01.011
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.description.bibliographicCitation Molés-Ribera, F.; Navarro Esbri, J.; Peris-Pérez, B.; Mota-Babiloni, A. (2016). Experimental evaluation of HCFO-1233zd-e as HFC-245fa replacement in an organic rankine cycle system for low temperature heat sources. Applied Thermal Engineering. 98:954-961. doi:10.1016/j.applthermaleng.2016.01.011 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/10.1016/j.applthermaleng.2016.01.011 es_ES
dc.description.upvformatpinicio 954 es_ES
dc.description.upvformatpfin 961 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 98 es_ES
dc.relation.senia 299094 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem