- -

Sizing of the buffer tank in chilled water distribution air-conditioning systems

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Sizing of the buffer tank in chilled water distribution air-conditioning systems

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Cervera Vázquez, Javier es_ES
dc.contributor.author Montagud Montalvá, Carla Isabel es_ES
dc.contributor.author Corberán Salvador, José Miguel es_ES
dc.date.accessioned 2017-05-26T07:29:06Z
dc.date.available 2017-05-26T07:29:06Z
dc.date.issued 2016
dc.identifier.issn 2374-4731
dc.identifier.uri http://hdl.handle.net/10251/81804
dc.description.abstract [♪EN] This paper presents a sizing study of the buffer tank in chilled water A/C systems. In order to find out the adequate sizing criteria for buffer tanks in these kind of installations, a review of different manufacturers' guidelines was carried out and it was concluded that there are three main operation parameters affected by the volume of the tank: the ON cycle time, the OFF cycle time, and the number of starts per hour of the chiller compressor. In order to better understand the influence of each parameter, a theoretical analysis was carried out where the impact of the building thermal load in different design criteria was also studied. After a thorough analysis of all the studied criteria, it was concluded that the minimum ON cycle time which is necessary to ensure that the oil returns to the compressor is the most critical criterion. Finally, a design guideline is proposed by the authors in order to determine the minimum volume of the buffer tank, mainly depending on the capacity of the chiller and the temperature deadband of the thermostat control. es_ES
dc.description.sponsorship This work was supported by the "Programa de Ayudas de Investigacion y Desarrollo (PAID)" of the Universitat Politecnica de Valencia. This work was also supported under the FP7 programme "Advanced ground source heat pump systems for heating and cooling in Mediterranean climate" (GROUND-MED project). en_EN
dc.language Inglés es_ES
dc.publisher Taylor & Francis es_ES
dc.relation.ispartof Science and Technology for the Built Environment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Buffer tank es_ES
dc.subject Chiller operation es_ES
dc.subject Hydraulic design es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Sizing of the buffer tank in chilled water distribution air-conditioning systems es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1080/23744731.2016.1131569
dc.relation.projectID info:eu-repo/grantAgreement/EC/FP7/218895/EU/Advanced ground source heat pump systems for heating and cooling in Mediterranean climate/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica es_ES
dc.description.bibliographicCitation Cervera Vázquez, J.; Montagud Montalvá, CI.; Corberán Salvador, JM. (2016). Sizing of the buffer tank in chilled water distribution air-conditioning systems. Science and Technology for the Built Environment. 22(3):290-298. https://doi.org/10.1080/23744731.2016.1131569 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/10.1080/23744731.2016.1131569 es_ES
dc.description.upvformatpinicio 290 es_ES
dc.description.upvformatpfin 298 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 22 es_ES
dc.description.issue 3 es_ES
dc.relation.senia 303431 es_ES
dc.identifier.eissn 2374-474X
dc.contributor.funder European Commission
dc.contributor.funder Universitat Politècnica de València


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem