Ye Lin, Y.; Bueno Barrachina, JM.; Prats-Boluda, G.; Rodríguez De Sanabria Gil, R.; Garcia Casado, FJ. (2017). Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode. Measurement. 97:195-202. https://doi.org/10.1016/j.measurement.2016.11.009
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/81977
Title:
|
Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode
|
Author:
|
Ye Lin, Yiyao
Bueno Barrachina, José Manuel
Prats-Boluda, Gema
Rodríguez de Sanabria Gil, Rafael
Garcia Casado, Francisco Javier
|
UPV Unit:
|
Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials
Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Caminos, Canales y Puertos - Escola Tècnica Superior d'Enginyers de Camins, Canals i Ports
Universitat Politècnica de València. Facultad de Administración y Dirección de Empresas - Facultat d'Administració i Direcció d'Empreses
Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
|
Issued date:
|
|
Abstract:
|
[EN] Concentric ring electrodes (CRE) have been proposed for sensing bioelectrical activity with high spatial resolution. Computational studies have revealed that the CRE dimensions are closely related to the electric ...[+]
[EN] Concentric ring electrodes (CRE) have been proposed for sensing bioelectrical activity with high spatial resolution. Computational studies have revealed that the CRE dimensions are closely related to the electric dipole depth they can sense, but further experimental confirmation is needed. We aimed to develop and test a wireless multichannel ECG recording system based on a new flexible multi-ring electrode and to check the influence of CRE dimensions on the acquired signals. The system provided high-precision ECG signals by a simple procedure. The bipolar concentric ECG signal amplitude and SNR increase with the CRE¿s outer ring dimension. Differences in the signal morphologies, associated with different sensitivities to the location of the active dipoles, were also obtained in the case of diameters smaller than 34 mm. A system with several wireless sensor nodes developed could be easily used by clinical staff for non-invasive cardiac monitoring and diagnosis with high spatial and temporal resolution.
[-]
|
Subjects:
|
Flexible multi-ring electrode
,
Wireless sensor node
,
Concentric ring electrode
|
Copyrigths:
|
Reserva de todos los derechos
|
Source:
|
Measurement. (issn:
0263-2241
) (eissn:
1873-412X
)
|
DOI:
|
10.1016/j.measurement.2016.11.009
|
Publisher:
|
Elsevier
|
Publisher version:
|
http://doi.org/10.1016/j.measurement.2016.11.009
|
Project ID:
|
info:eu-repo/grantAgreement/GVA//GV%2F2014%2F029/
info:eu-repo/grantAgreement/UPV//SP20120490/
info:eu-repo/grantAgreement/MINECO//DPI2015-68397-R/ES/ELECTROHISTEROGRAFIA, CONSTRUYENDO PUENTES PARA SU USO CLINICO EN OBSTETRICIA/
|
Thanks:
|
Research supported in part by a grant from the Conselleria d'Educacio, Cultura I Esport, Generalitat Valenciana Conselleria - Spain (GV/2014/029); by a grant from the Universitat Politecnica de Valencia - Spain (SP20120490); ...[+]
Research supported in part by a grant from the Conselleria d'Educacio, Cultura I Esport, Generalitat Valenciana Conselleria - Spain (GV/2014/029); by a grant from the Universitat Politecnica de Valencia - Spain (SP20120490); and by the Ministry of Economy and Competitiveness - Spain and the European Regional Development Fund (DPI2015-68397-R (MINECO/FEDER)).
[-]
|
Type:
|
Artículo
|