Linking instantaneous rate of injection to X-ray needle lift measurements for a direct-acting piezoelectric injector

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Linking instantaneous rate of injection to X-ray needle lift measurements for a direct-acting piezoelectric injector

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Viera-Sotillo, Juan Pablo es_ES
dc.contributor.author Payri, Raul es_ES
dc.contributor.author Swantek, Andrew B. es_ES
dc.contributor.author Duke, Daniel J. es_ES
dc.contributor.author Sovis, Nicolas es_ES
dc.contributor.author Kastengren, Alan L. es_ES
dc.contributor.author Powell, Christopher F. es_ES
dc.date.accessioned 2017-05-31T11:24:26Z
dc.date.available 2017-05-31T11:24:26Z
dc.date.issued 2016-03-15
dc.identifier.issn 0196-8904
dc.identifier.uri http://hdl.handle.net/10251/82094
dc.description.abstract Internal combustion engines have been and still are key players in today's world. Ever increasing fuel consumption standards and the ongoing concerns about exhaust emissions have pushed the industry to research new concepts and develop new technologies that address these challenges. To this end, the diesel direct injection system has recently seen the introduction of direct-acting piezoelectric injectors, which provide engineers with direct control over the needle lift, and thus instantaneous rate of injection (ROI). Even though this type of injector has been studied previously, no direct link between the instantaneous needle lift and the resulting rate of injection has been quantified. This study presents an experimental analysis of the relationship between instantaneous partial needle lifts and the corresponding ROI. A prototype direct-acting injector was utilized to produce steady injections of different magnitude by partially lifting the needle. The ROI measurements were carried out at CMT-Motores Termicos utilizing a standard injection rate discharge curve indicator based on the Bosch method (anechoic tube). The needle lift measurements were performed at the Advanced Photon Source at Argonne National Laboratory. The analysis seeks both to contribute to the current understanding of the influence that partial needle lifts have over the instantaneous ROI and to provide experimental data with parametric variations useful for numerical model validations. Results show a strong relationship between the steady partial needle lift and the ROI. The effect is non-linear, and also strongly dependent on the injection pressure. The steady lift value at which the needle ceases to influence the ROI increases with the injection pressure. Finally, a transient analysis is presented, showing that the needle velocity may considerably affect the instantaneous ROI, because of the volume displaced inside the nozzle. Results presented in this study show that at constant injection pressure and energizing time, this injector has the potential to control many aspects of the ROI and thus, the heat release rate. Also, data presented are useful for numerical model validations, which would provide detailed insight into the physical processes that drive these observations, and potentially, to the effects of these features on combustion performance. es_ES
dc.description.sponsorship The submitted manuscript has been created by UChicago Argonne, LLC, Operator of Argonne National Laboratory (Argonne). Argonne, a U.S. Department of Energy Office of Science laboratory, is operated under Contract No. DE-AC02-06CH11357. The U.S. Government retains for itself, and others acting on its behalf, a paid-up nonexclusive, irrevocable worldwide license in said article to reproduce, prepare derivative works, distribute copies to the public, and perform publicly and display publicly, by or on behalf of the Government. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Energy Conversion and Management es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Diesel direct injection es_ES
dc.subject Rate of injection es_ES
dc.subject Synchrotron es_ES
dc.subject X-ray imaging es_ES
dc.subject Needle lift es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Linking instantaneous rate of injection to X-ray needle lift measurements for a direct-acting piezoelectric injector es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.enconman.2016.01.038
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//TRA2012-36932/ES/COMPRENSION DE LA INFLUENCIA DE COMBUSTIBLES NO CONVENCIONALES EN EL PROCESO DE INYECCION Y COMBUSTION TIPO DIESEL/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MECD//PRX14%2F00331/ES/PRX14%2F00331/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//EEBB-I-15-09716/ES/EEBB-I-15-09716/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/DOE//DE-AC02-06CH11357/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario CMT-Motores Térmicos - Institut Universitari CMT-Motors Tèrmics es_ES
dc.description.bibliographicCitation Viera-Sotillo, JP.; Payri, R.; Swantek, AB.; Duke, DJ.; Sovis, N.; Kastengren, AL.; Powell, CF. (2016). Linking instantaneous rate of injection to X-ray needle lift measurements for a direct-acting piezoelectric injector. Energy Conversion and Management. 112:350-358. https://doi.org/10.1016/j.enconman.2016.01.038 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/10.1016/j.enconman.2016.01.038 es_ES
dc.description.upvformatpinicio 350 es_ES
dc.description.upvformatpfin 358 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 112 es_ES
dc.relation.senia 328444 es_ES
dc.contributor.funder Ministerio de Educación, Cultura y Deporte es_ES
dc.contributor.funder U.S. Department of Energy es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem