Navarro-Peris, E.; Martínez Galván, IO.; Nohales Herraiz, JÁ.; Gonzálvez Maciá, J. (2013). Comparative experimental study of an open piston compressor working with R-1234yf, R-134a and R-290. International Journal of Refrigeration. 36(3):768-775. https://doi.org/10.1016/j.ijrefrig.2012.11.017
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/82198
Title:
|
Comparative experimental study of an open piston compressor working with R-1234yf, R-134a and R-290
|
Secondary Title:
|
Etude expérimentale comparative sur un compresseur à piston ouvert fonctionnant au R-1234yf, au R-134a ou au R-290
|
Author:
|
Navarro-Peris, Emilio
Martínez Galván, Israel Octavio
Nohales Herraiz, Jesús Ángel
Gonzálvez Maciá, José
|
UPV Unit:
|
Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials
Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica
Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
|
Issued date:
|
|
Abstract:
|
Among the different alternatives proposed in the automotive field to replace R-134a and R-1234yf is a new generation fluid which has recently gained great importance for MAC (Mobile Air Conditioning) systems. This fluid ...[+]
Among the different alternatives proposed in the automotive field to replace R-134a and R-1234yf is a new generation fluid which has recently gained great importance for MAC (Mobile Air Conditioning) systems. This fluid has the advantage of having a low GWP (Global Warming potential) and thermodynamic properties similar to R-134a. But there is some criticism regarding the non-natural origin of the fluid and its possible long-term effects on the environment have not been studied. In that sense, hydrocarbons and particularly R-290 can be considered as alternatives. This paper presents a comparative study between R-1234yf, R-134a and R-290 for an open piston compressor at different operating conditions. The text matrix comprised two compressor speeds, evaporation temperatures from -15 °C to 15 °C and condensation temperatures from 40 °C to 65 °C. From these tests, the compressor behavior with these refrigerants has systematically been analyzed in terms of compressor efficiency, volumetric efficiency, losses to the ambient and oil-refrigerant properties.
[-]
|
Subjects:
|
Open compressors
,
Refrigerants
,
Hydrocarbons
,
R1234yf
,
Automotive air conditioning
,
Compresseurs ouverts
,
Frigorigènes
,
Hydrocarbures
,
Conditionnement d’air automobile
|
Copyrigths:
|
Cerrado |
Source:
|
International Journal of Refrigeration. (issn:
0140-7007
)
|
DOI:
|
10.1016/j.ijrefrig.2012.11.017
|
Publisher:
|
Elsevier
|
Publisher version:
|
http://dx.doi.org/10.1016/j.ijrefrig.2012.11.017
|
Project ID:
|
info:eu-repo/grantAgreement/MICINN//TRA2009_0062/ES/Diseño Asistido por Ordenador de Equipos de Refrigeración y Bomba de Calor/
|
Thanks:
|
The authors are very grateful to the Spanish Ministerio de Economia y competitividad through the program "Programa Nacional de Proyectos de Investigacion Fundamental" for the support given to the Project "Diseno Asistido ...[+]
The authors are very grateful to the Spanish Ministerio de Economia y competitividad through the program "Programa Nacional de Proyectos de Investigacion Fundamental" for the support given to the Project "Diseno Asistido por Ordenador de Equipos de Refrigeracion y Bomba de Calor" ref. TRA2009-0062.
[-]
|
Type:
|