Application of a Montecarlo based quantitative Kramers-Kronig test for linearity assessment of EIS measurements

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Application of a Montecarlo based quantitative Kramers-Kronig test for linearity assessment of EIS measurements

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Giner-Sanz, Juan José es_ES
dc.contributor.author Ortega Navarro, Emma María es_ES
dc.contributor.author Pérez-Herranz, Valentín es_ES
dc.date.accessioned 2017-06-02T10:39:53Z
dc.date.available 2017-06-02T10:39:53Z
dc.date.issued 2016-08-10
dc.identifier.issn 0013-4686
dc.identifier.uri http://hdl.handle.net/10251/82252
dc.description.abstract Electrochemical Impedance Spectroscopy (EIS) is a very powerful tool to study the behaviour of electrochemical systems. Three conditions must be fulfilled during EIS measurements: causality, linearity, and stability. If any of these conditions is not achieved, then the conclusions obtained from the analysis of the measured spectra may be biased, or even misguided. For this reason, the verification of the compliance of these conditions is critical before accepting any analysis performed on an experimental spectrum. In a previous work, an experimental spectrum quantitative validation technique based on Kramers-Kronig relations was presented. The validation method consists in a Kramers-Kronig (KK) validation test, by equivalent electrical circuit fitting, coupled with a Montecarlo error propagation method. The validation technique builds a consistency region for a given confidence level that allows to discriminate between the individual points of the EIS spectrum that are consistent with the four fundamental hypotheses, and the inconsistent ones. The aim of this work is to validate experimentally if the quantitative validation technique is able to detect nonlinearities. In order to achieve this goal, the EIS spectrum of a markedly nonlinear system was measured experimentally using different perturbation amplitudes. The validation technique was applied to each one of the measured spectra. The method successfully managed to identify large nonlinearities; but did not detect slight ones. es_ES
dc.description.sponsorship The authors are very grateful to the Generalitat Valenciana for its economic support in form of Vali + d grant (Ref: ACIF-2013-268). en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Electrochimica Acta es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Electrochemical impedance spectroscopy (EIS) es_ES
dc.subject Kramers-Kronig es_ES
dc.subject Montecarlo algorithm es_ES
dc.subject Quantitative validation es_ES
dc.subject Linearity assessment method es_ES
dc.subject.classification INGENIERIA QUIMICA es_ES
dc.title Application of a Montecarlo based quantitative Kramers-Kronig test for linearity assessment of EIS measurements es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.electacta.2016.04.131
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACIF%2F2013%2F268/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.description.bibliographicCitation Giner-Sanz, JJ.; Ortega Navarro, EM.; Pérez-Herranz, V. (2016). Application of a Montecarlo based quantitative Kramers-Kronig test for linearity assessment of EIS measurements. Electrochimica Acta. 209:254-268. https://doi.org/10.1016/j.electacta.2016.04.131 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/10.1016/j.electacta.2016.04.131 es_ES
dc.description.upvformatpinicio 254 es_ES
dc.description.upvformatpfin 268 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 209 es_ES
dc.relation.senia 314117 es_ES
dc.identifier.eissn 1873-3859
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)