- -

Investigation of the CRT performance of a PET scanner based in liquid xenon: a Monte Carlo study

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Investigation of the CRT performance of a PET scanner based in liquid xenon: a Monte Carlo study

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Gómez-Cadenas, J. J. es_ES
dc.contributor.author Benlloch-Rodriguez, J. M. es_ES
dc.contributor.author Ferrario, Paola es_ES
dc.contributor.author Monrabal, F. es_ES
dc.contributor.author Rodriguez-Samaniego, Javier es_ES
dc.contributor.author Toledo Alarcón, José Francisco es_ES
dc.date.accessioned 2017-06-02T15:00:08Z
dc.date.available 2017-06-02T15:00:08Z
dc.date.issued 2016-09-26
dc.identifier.issn 1748-0221
dc.identifier.uri http://hdl.handle.net/10251/82280
dc.description.abstract The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the coincidence resolving time (CRT) of the gammas is sufficiently good. Existing commercial systems based in LYSO crystals, such as the GEMINIS of Philips, reach CRT values of 600 ps (FWHM). In this paper we present a Monte Carlo investigation of the CRT performance of a PET scanner exploiting the scintillating properties of liquid xenon. We find that an excellent CRT of 60 70 ps (depending on the PDE of the sensor) can be obtained if the scanner is instrumented with silicon photomultipliers (SiPMs) sensitive to the ultraviolet light emitted by xenon. Alternatively, a CRT of 120 ps can be obtained instrumenting the scanner with (much cheaper) blue-sensitive SiPMs coated with a suitable wavelength shifter. These results show the excellent time of flight capabilities of a PET device based in liquid xenon. es_ES
dc.description.sponsorship The authors acknowledge support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT, the Ministerio de Economia y Competitividad and FEDER of Spain, the Severo Ochoa Program SEV-2014-0398 and GVA under grant PROMETEO/2016/120; we acknowledge enlightening discussions with J. Varela and C. Lerche. en_EN
dc.language Inglés es_ES
dc.publisher IOP Publishing es_ES
dc.relation.ispartof Journal of Instrumentation es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject PET es_ES
dc.subject TOF es_ES
dc.subject Liquid xenon es_ES
dc.subject Energy resolution es_ES
dc.subject High sensitivity es_ES
dc.subject Coincidence resolving time (CRT) es_ES
dc.subject SiPMs es_ES
dc.subject LYSO es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Investigation of the CRT performance of a PET scanner based in liquid xenon: a Monte Carlo study es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1088/1748-0221/11/09/P09011
dc.relation.projectID info:eu-repo/grantAgreement/EC/FP7/339787/EU/Towards the NEXT generation of bb0nu experimets/ en_EN
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//SEV-2014-0398/ES/INSTITUTO DE FISICA CORPUSCULAR (IFIC)/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEO%2F2016%2F120/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia es_ES
dc.description.bibliographicCitation Gómez-Cadenas, JJ.; Benlloch-Rodriguez, JM.; Ferrario, P.; Monrabal, F.; Rodriguez-Samaniego, J.; Toledo Alarcón, JF. (2016). Investigation of the CRT performance of a PET scanner based in liquid xenon: a Monte Carlo study. Journal of Instrumentation. 11(P09011). https://doi.org/10.1088/1748-0221/11/09/P09011 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1088/1748-0221/11/09/P09011 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 11 es_ES
dc.description.issue P09011 es_ES
dc.relation.senia 307411 es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder European Regional Development Fund es_ES
dc.contributor.funder European Commission


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem