- -

The location of the tibial accelerometer does influence impact acceleration parameters during running

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

The location of the tibial accelerometer does influence impact acceleration parameters during running

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Lucas Cuevas, Ángel Gabriel es_ES
dc.contributor.author Encarnacion Martinez, Alberto es_ES
dc.contributor.author Camacho García, Andrés es_ES
dc.contributor.author Llana Belloch, Salvador es_ES
dc.contributor.author Pérez Soriano, Pedro es_ES
dc.date.accessioned 2017-06-28T10:25:10Z
dc.date.available 2017-06-28T10:25:10Z
dc.date.issued 2016-10
dc.identifier.issn 0264-0414
dc.identifier.uri http://hdl.handle.net/10251/83909
dc.description.abstract Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made. © 2016 Informa UK Limited, trading as Taylor & Francis Group es_ES
dc.description.sponsorship This study was supported by the Spanish Government [Ministerio de Educacion, Cultura y Deporte, Grant FPU12/00574; and Ministerio de Economia y Competitividad, Subdireccion General de Proyectos de Investigacion, Convocatoria Proyectos I+D "Excelencia", Subprograma de Generacion de Conocimiento, 2013, Grant DEP2013-48420-P]. en_EN
dc.language Inglés es_ES
dc.publisher Taylor & Francis es_ES
dc.relation.ispartof Journal of Sports Sciences es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Accelerometry es_ES
dc.subject Deceleration es_ES
dc.subject Frequency analysis es_ES
dc.subject Shock attenuation es_ES
dc.subject Tibial acceleration es_ES
dc.subject.classification TEORIA DE LA SEÑAL Y COMUNICACIONES es_ES
dc.title The location of the tibial accelerometer does influence impact acceleration parameters during running es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1080/02640414.2016.1235792
dc.relation.projectID info:eu-repo/grantAgreement/MECD//FPU12%2F00574/ES/FPU12%2F00574/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//DEP2013-48420-P/ES/NALISIS DE LA PLANTILLA DEPORTIVA: PREFABRICADAS VS PERSONALIZAS SOBRE PARAMETROS BIOMECANICOS EN FATIGA DURANTE LA CARRERA/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Grupo de Comunicaciones Aplicadas a Redes Telemáticas (GATACA) es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario Mixto de Biomecánica de Valencia - Institut Universitari Mixt de Biomecànica de València es_ES
dc.description.bibliographicCitation Lucas Cuevas, ÁG.; Encarnacion Martinez, A.; Camacho García, A.; Llana Belloch, S.; Pérez Soriano, P. (2016). The location of the tibial accelerometer does influence impact acceleration parameters during running. Journal of Sports Sciences. 35(17):1734-1738. https://doi.org/10.1080/02640414.2016.1235792 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1080/02640414.2016.1235792 es_ES
dc.description.upvformatpinicio 1734 es_ES
dc.description.upvformatpfin 1738 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 35 es_ES
dc.description.issue 17 es_ES
dc.relation.senia 323501 es_ES
dc.identifier.eissn 1466-447X
dc.contributor.funder Ministerio de Educación, Cultura y Deporte es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem