Mostrar el registro sencillo del ítem
dc.contributor.author | Lucas Cuevas, Ángel Gabriel![]() |
es_ES |
dc.contributor.author | Encarnacion Martinez, Alberto![]() |
es_ES |
dc.contributor.author | Camacho García, Andrés![]() |
es_ES |
dc.contributor.author | Llana Belloch, Salvador![]() |
es_ES |
dc.contributor.author | Pérez Soriano, Pedro![]() |
es_ES |
dc.date.accessioned | 2017-06-28T10:25:10Z | |
dc.date.available | 2017-06-28T10:25:10Z | |
dc.date.issued | 2016-10 | |
dc.identifier.issn | 0264-0414 | |
dc.identifier.uri | http://hdl.handle.net/10251/83909 | |
dc.description.abstract | Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made. © 2016 Informa UK Limited, trading as Taylor & Francis Group | es_ES |
dc.description.sponsorship | This study was supported by the Spanish Government [Ministerio de Educacion, Cultura y Deporte, Grant FPU12/00574; and Ministerio de Economia y Competitividad, Subdireccion General de Proyectos de Investigacion, Convocatoria Proyectos I+D "Excelencia", Subprograma de Generacion de Conocimiento, 2013, Grant DEP2013-48420-P]. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Taylor & Francis | es_ES |
dc.relation.ispartof | Journal of Sports Sciences | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Accelerometry | es_ES |
dc.subject | Deceleration | es_ES |
dc.subject | Frequency analysis | es_ES |
dc.subject | Shock attenuation | es_ES |
dc.subject | Tibial acceleration | es_ES |
dc.subject.classification | TEORIA DE LA SEÑAL Y COMUNICACIONES | es_ES |
dc.title | The location of the tibial accelerometer does influence impact acceleration parameters during running | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1080/02640414.2016.1235792 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MECD//FPU12%2F00574/ES/FPU12%2F00574/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//DEP2013-48420-P/ES/NALISIS DE LA PLANTILLA DEPORTIVA: PREFABRICADAS VS PERSONALIZAS SOBRE PARAMETROS BIOMECANICOS EN FATIGA DURANTE LA CARRERA/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Grupo de Comunicaciones Aplicadas a Redes Telemáticas (GATACA) | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto de Biomecánica de Valencia - Institut Universitari Mixt de Biomecànica de València | es_ES |
dc.description.bibliographicCitation | Lucas Cuevas, ÁG.; Encarnacion Martinez, A.; Camacho García, A.; Llana Belloch, S.; Pérez Soriano, P. (2016). The location of the tibial accelerometer does influence impact acceleration parameters during running. Journal of Sports Sciences. 35(17):1734-1738. https://doi.org/10.1080/02640414.2016.1235792 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1080/02640414.2016.1235792 | es_ES |
dc.description.upvformatpinicio | 1734 | es_ES |
dc.description.upvformatpfin | 1738 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 35 | es_ES |
dc.description.issue | 17 | es_ES |
dc.relation.senia | 323501 | es_ES |
dc.identifier.eissn | 1466-447X | |
dc.contributor.funder | Ministerio de Educación, Cultura y Deporte | es_ES |